About This Item

Linear Formula:
CF3COOH
CAS Number:
Molecular Weight:
114.02
Beilstein:
742035
EC Number:
MDL number:
UNSPSC Code:
12352106
PubChem Substance ID:
NACRES:
NA.21

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

vapor density

3.9 (vs air)

Quality Level

vapor pressure

97.5 mmHg ( 20 °C)

type

for protein sequencing

Assay

≥99%

form

liquid

impurities

<0.05% water

evapn. residue

<0.005%

refractive index

n20/D 1.3 (lit.)

pH

1 (20 °C, 10 g/L)

bp

72.4 °C (lit.)

mp

−15.4 °C (lit.)

solubility

water: soluble 10.000 g/L

density

1.489 g/mL at 20 °C (lit.)

SMILES string

OC(C(F)(F)F)=O

InChI

1S/C2HF3O2/c3-2(4,5)1(6)7/h(H,6,7)

InChI key

DTQVDTLACAAQTR-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
917078.0826074564
assay

≥99%

assay

≥99.0% (GC)

assay

≥99% (acidimetric)

assay

≥99.0% (GC)

Quality Level

100

Quality Level

200

Quality Level

200

Quality Level

100

form

liquid

form

liquid

form

liquid

form

-

pH

1 (20 °C, 10 g/L)

pH

1 (20 °C, 1 g/L)

pH

1 (10 g/L in H2O)

pH

-

impurities

<0.05% water

impurities

≤0.05% water

impurities

-

impurities

≤0.05% water

bp

72.4 °C (lit.)

bp

72.4 °C (lit.)

bp

72.4 °C (lit.)

bp

72.4 °C (lit.)

General description

Our biotech solvents offer exceptional quality for reliable RNA extraction, ensuring optimal laboratory performance. With low water content and minimal residue, give clean UV spectra to minimize contamination.
  • High-Quality Biotech Solvents: Designed for optimal laboratory performance with low water content and minimal residues.
  • Ideal for RNA Extraction: Essential for genetic testing and research applications like PCR.
  • Ensures Integrity of Genetic Material: Promotes reliable and reproducible results.
  • Industry Compliant: Suitable for both academic and commercial laboratories, enhancing research efficiency.

Trifluoroacetic acid is a naturally occurring organic solvent and biodegradable by microbial action. It can also be used as a catalyst for various organic transformations, including solvolysis, rearrangements, reductions, oxidations, and trifluoromethylation.

Application

Trifluoroacetic acid can be used as a solvent in the:
  • Mass spectrometry for protein identification.
  • Microwave-irradiated bromination of isoxazoles and pyrazoles with N-bromosuccinimide to synthesize mono-brominated isoxazoles and pyrazoles.
  • Lewis acid-catalyzed 6-endo-digcyclization of 2-(2-arylethynyl)heteroaryl esters to heterocyclic lactones.
  • Electrospinning of cellulose acetate to prepare the corresponding nanofibrous membranes.

Pictograms

CorrosionExclamation mark

Signal Word

Danger

Hazard Statements

Hazard Classifications

Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Eye Dam. 1 - Skin Corr. 1A

Storage Class Code

8A - Combustible corrosive hazardous materials

WGK

WGK 2

Flash Point(F)

No data available

Flash Point(C)

No data available


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

ISHL Indicated Name

Substances Subject to be Indicated Names

ISHL Notified Names

Substances Subject to be Notified Names

JAN Code

299537-25G:
299537-50ML:
299537-500G:
299537-2L:
299537-5KG:
299537-BULK:
299537-100G:
299537-VAR:
299537-50G:
QR-047-100G:


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Andrew C Tolonen et al.
Journal of visualized experiments : JoVE, (89)(89), doi:10-doi:10 (2014-07-22)
Stable isotope labeling of peptides by reductive dimethylation (ReDi labeling) is a method to accurately quantify protein expression differences between samples using mass spectrometry. ReDi labeling is performed using either regular (light) or deuterated (heavy) forms of formaldehyde and sodium
Continuous-flow synthesis of the anti-malaria drug artemisinin.
François Lévesque et al.
Angewandte Chemie (International ed. in English), 51(7), 1706-1709 (2012-01-18)
Guangfa Shi et al.
Organic letters, 17(1), 38-41 (2014-12-18)
Direct trifluoromethylation of arenes using TFA as the trifluoromethylating reagent was achieved with Ag as the catalyst. This reaction not only provides a new protocol for aryl C-H trifluoromethylation, but the generation of CF3· from TFA may prove useful in
W C Mahoney et al.
The Journal of biological chemistry, 255(23), 11199-11203 (1980-12-10)
A method employing reverse phase high performance liquid chromatography has been developed for the purification of large denatured peptides. The cyanogen bromide fragments of hemoglobin alpha, beta, and gamma chains (13 to 91 residues in length) could be separated and
Macro- and micromethods for the determination of serum vitamin A using trifluoroacetic acid.
J B Neeld et al.
The Journal of nutrition, 79, 454-462 (1963-04-01)

Protocols

BIOshell™ IgG 1000 Å C4 UHPLC Column for Improved Biomacromolecule Separations

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service