コンテンツへスキップ
Merck
  • Solid-phase microextraction and gas chromatography-mass spectrometry for analysis of phenols and nitrophenols in rainwater, as their t-butyldimethylsilyl derivatives.

Solid-phase microextraction and gas chromatography-mass spectrometry for analysis of phenols and nitrophenols in rainwater, as their t-butyldimethylsilyl derivatives.

Analytical and bioanalytical chemistry (2007-01-30)
Farouk Jaber, Claude Schummer, Jamal Al Chami, Philippe Mirabel, Maurice Millet
要旨

Solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry has been used for analysis of four phenols and sixteen nitrophenols in rainwater samples. Analytes were extracted from the water in the immersion mode and derivatised for 5 min during direct desorption in the GC injector. Before desorption, 2 microL N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide (MDBSTFA) was introduced into the injector, which was maintained at 280 degrees C. Different conditions affecting extraction efficiency were studied, including temperature, type of microextraction fibre, and effect of pH and ionic strength. Five different fibre coatings were tested: 85-mum polyacrylate (PA), 100-microm polydimethylsiloxane (PDMS), 65-mum Carbowax-divinylbenzene (CW-DVB), 75-microm Carboxen-polydimethylsiloxane (CAR-PDMS), and 65-microm polydimethylsiloxane-divinylbenzene (PDMS-DVB). The best conditions were use of PA fibres for 40 min at ambient temperature (75 g NaCl per 100 mL, pH 3.0). MDBSTFA was used as derivatising agent because it enables analysis of phenols derivatives with high confidence in identification, because in electron-impact mode TBDMS-phenol derivatives produce the specific M-57 ion. Quantification was achieved by using 4-nitrophenol-d4, at 1 mg L(-1), as internal standard. Linearity was good, with correlation coefficients in the range 0.9888 (o-cresol) to 0.9987 (dinitro-o-cresol, DNOC). Detection limits varied between 0.208 and 99.3 microg L(-1) and quantification limits between 0.693 and 331 microg L(-1). Uncertainties varied between 8.7% (phenol) and 17.9% (4-methyl-2-nitrophenol). The method was successfully applied to the analysis of rainwater collected at urban and rural sites in Alsace (East of France). Because of derivatisation in the injector and the associated high temperature, the lifetime of the fibre is severely reduced.

材料
製品番号
ブランド
製品内容

Supelco
SPMEファイバーアセンブリ, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPMEファイバーアセンブリ, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 24 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPMEファイバーアセンブリ, 50/30µm DVB/CAR/PDMS, StableFlex (1cm), needle size 24 ga, Manual Holder, pk of 3, plain gray hub
Supelco
SPMEファイバーアセンブリ, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPMEファイバーアセンブリ, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, plain gray hub
Supelco
ORBO Carboxen-564チューブ, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Carboxen® 564特殊洗浄済み(20/45)、400/200 mg入りORBO 78 HBR, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
Carboxen®-1010 PLOTキャピラリーGCカラム, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Carboxen®吸着剤, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, black hub
Supelco
Carboxen®-1006 PLOTキャピラリーGCカラム, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, black hub
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, light blue hub
Supelco
Carboxen®-1010 PLOTキャピラリーGCカラム, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, light blue hub
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, light blue hub
Supelco
Carboxen® 1000, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, black hub
Supelco
Carboxen®-1006 PLOTキャピラリーGCカラム, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Tenax® TA / Carboxen® 1018, glass TD tube, preconditioned, O.D. × L 1/4 in. × 3 1/2 in., Sealed with (Swagelok® End-Fittings), pkg of 10 ea
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, black hub
Supelco
Carboxen® 1003, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
SPMEファイバーアセンブリ, 50/30µm DVB/CAR/PDMS, Metal Alloy (2cm), needle size 23 ga, Autosampler, pk of 1, plain gray hub
Supelco
カルボキセン® 572 for Tobacco Smoke, Adsorbent Bed Wt: 300 mg, cartridge size 3 mL, pkg of 50 ea
Supelco
SPMEファイバーアセンブリ, 50/30µm DVB/CAR/PDMS, Metal Alloy (1cm), needle size 23 ga, Autosampler, pk of, plain gray hub
Supelco
Carboxen®吸着剤, matrix Carboxen® 569, 20-45 mesh, bottle of 10 g
Supelco
Carboxen® 1000リバーシブルSPEチューブ, 200 mg/mL, pk 30
Supelco
Carboxen®吸着剤, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
Carboxen®吸着剤, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), 85 μm CAR/PDMS, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 1, light blue hub