コンテンツへスキップ
Merck

Cell response of anodized nanotubes on titanium and titanium alloys.

Journal of biomedical materials research. Part A (2013-02-26)
Sepideh Minagar, James Wang, Christopher C Berndt, Elena P Ivanova, Cuie Wen
要旨

Titanium and titanium alloy implants that have been demonstrated to be more biocompatible than other metallic implant materials, such as Co-Cr alloys and stainless steels, must also be accepted by bone cells, bonding with and growing on them to prevent loosening. Highly ordered nanoporous arrays of titanium dioxide that form on titanium surface by anodic oxidation are receiving increasing research interest due to their effectiveness in promoting osseointegration. The response of bone cells to implant materials depends on the topography, physicochemistry, mechanics, and electronics of the implant surface and this influences cell behavior, such as adhesion, proliferation, shape, migration, survival, and differentiation; for example the existing anions on the surface of a titanium implant make it negative and this affects the interaction with negative fibronectin (FN). Although optimal nanosize of reproducible titania nanotubes has not been reported due to different protocols used in studies, cell response was more sensitive to titania nanotubes with nanometer diameter and interspace. By annealing, amorphous TiO2 nanotubes change to a crystalline form and become more hydrophilic, resulting in an encouraging effect on cell behavior. The crystalline size and thickness of the bone-like apatite that forms on the titania nanotubes after implantation are also affected by the diameter and shape. This review describes how changes in nanotube morphologies, such as the tube diameter, the thickness of the nanotube layer, and the crystalline structure, influence the response of cells.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
チタン, foil, thickness 0.127 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 0.25 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, powder, <45 μm avg. part. size, 99.98% trace metals basis
Sigma-Aldrich
チタン, powder, −100 mesh, 99.7% trace metals basis
チタン, mesh, 100x100mm, nominal aperture 0.19mm, wire diameter 0.23mm, 60x60 wires/inch, open area 20%, twill weave
Sigma-Aldrich
チタン, wire, diam. 0.25 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, sponge, 1-20 mm, 99.5% trace metals basis
Sigma-Aldrich
チタン, sputtering target, diam. × thickness 2.00 in. × 0.25 in., 99.995% trace metals basis
チタン, mesh, 100x100mm, nominal aperture 4.3mm, wire diameter 1.5mm, 4.4x4.4 wires/inch, open area 94%, platinized diamond mesh
Sigma-Aldrich
チタン, foil, thickness 0.025 mm, 99.98% trace metals basis
Sigma-Aldrich
チタン, ≤10 mm, ≥99.99% trace metals basis (purity exclusive of Na and K content)
Sigma-Aldrich
チタン, foil, thickness 0.25 mm, 99.99% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 0.5 mm, 99.99% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 2.0 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 0.127 mm, ≥99.99% trace metals basis
Sigma-Aldrich
チタン, evaporation slug, diam. × L 6.3 mm × 6.3 mm, ≥99.99% trace metals basis
Sigma-Aldrich
チタン, wire, diam. 0.81 mm, 99.7% trace metals basis
チタン, rod, 10mm, diameter 50mm, 99.99+%
Sigma-Aldrich
チタン, wire, diam. 1.0 mm, 99.99% trace metals basis
チタン, rod, 25mm, diameter 50mm, 99.99+%
Sigma-Aldrich
チタン, wire, diam. 0.5 mm, 99.99% trace metals basis
チタン, wire, straight, 1000mm, diameter 1.0mm, as drawn, 99.6+%
チタン, tube, 200mm, outside diameter 2.03mm, inside diameter 1.55mm, wall thickness 0.24mm, annealed, 99.6+%
チタン, wire reel, 25m, diameter 0.20mm, annealed, 99.6+%
チタン, wire reel, 2m, diameter 1.0mm, as drawn, 99.99+%
チタン, rod, 200mm, diameter 2mm, as drawn, 99.99+%
チタン, rod, 1000mm, diameter 2mm, annealed, 99.6+%
チタン, rod, 1000mm, diameter 1.5mm, annealed, 99.6+%
チタン, tube, 500mm, outside diameter 9.5mm, inside diameter 8.2mm, wall thickness 0.65mm, annealed, 99.6+%
チタン, rod, 100mm, diameter 2mm, annealed, 99.6+%