Select a Size
About This Item
Skip To
material
polysulfone device
polysulfone support
Quality Level
Agency
meets EP 2.6.14
meets JP 4.01
meets USP 85
sterility
sterile; irradiated
product line
Millipak® Final Fill 60
feature
hydrophilic
manufacturer/tradename
Millipak®
parameter
0.51 L/min flow rate at 0.69 bar (Δ P)
0.7 bar max. differential pressure (10 psi) at 25 °C (Reverse)
3.5 bar max. inlet pressure (50 psi) at 25 °C
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
technique(s)
sterile filtration: suitable
filter filtration area
300 cm2
inlet connection diam.
1.5 in. , sanitary flange
outlet connection diam.
1.5 in.
impurities
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
matrix
Durapore®
pore size
0.1 μm pore size
bubble point
≥4830 mbar (70 psi), air with water
fitting
(38 mm (1½ in.) Sanitary Flange Inlet and Outlet)
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | MFVL06GT3 | MFGB06ST3 | MFGL06ST3 |
|---|---|---|---|
| pore size 0.1 μm pore size | pore size 0.1 μm pore size | pore size 0.22 μm pore size | pore size 0.22 μm pore size |
| product line Millipak® Final Fill 60 | product line Millipak® Final Fill 60 | product line Millipak® Final Fill 60 | product line Millipak® Final Fill 60 |
| technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable |
| matrix Durapore® | matrix Durapore® | matrix Durapore® | matrix Durapore® |
| material polysulfone device, polysulfone support | material polysulfone device, polysulfone support | material polysulfone device, polysulfone support | material polysulfone device, polysulfone support |
| manufacturer/tradename Millipak® | manufacturer/tradename Millipak® | manufacturer/tradename Millipak® | manufacturer/tradename Millipak® |
General description
Packaging
Preparation Note
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer general guidelines section of user guide shipped with this product
- Storage Statement: Please refer user guide shipped with this product
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Stay compliant with GMP using the Emprove® Program
Accelerate qualification, maintain compliance, and save time with Emprove® Dossiers.
Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.
Register for free and access Emprove® Dossiers within minutes. Upgrade your subscription plan to unlock advanced and customized content in the Emprove® Suite
Not finding what you are looking for? Visit the Emprove® Program Help page.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service