Przejdź do zawartości
Merck
  • Development and validation of a high-performance liquid chromatography-fluorescence detection method for the accurate quantification of colistin in human plasma.

Development and validation of a high-performance liquid chromatography-fluorescence detection method for the accurate quantification of colistin in human plasma.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-01-16)
Divyabharathi Chepyala, I-Lin Tsai, Hsin-Yun Sun, Shu-Wen Lin, Ching-Hua Kuo
ABSTRAKT

Recently, colistin has become one of the most important drugs for treating infections caused by multidrug-resistant Gram-negative bacteria. Therapeutic drug monitoring is recommended to ensure the safety and efficacy of colistin and to improve clinical outcomes. This study developed an accurate and sensitive high-performance liquid chromatography-fluorescence detection (HPLC-FLD) method for the quantification of colistin in human plasma. The sample preparation included protein precipitation using trichloroacetic acid (TCA) and methanol, followed by in-solid phase extraction (In-SPE) derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl). A Poroshell 120 EC-C18 2.1×100mm (2.7μm) column was used in the HPLC method with a mobile phase composed of acetonitrile (ACN), tetrahydrofuran (THF), and deionized (DI) water (82%, 2%, 16% (v/v), respectively). Polymyxin B1 was used as the internal standard. The total analysis time was 22min under optimal separation conditions. The HPLC-FLD method was validated over a therapeutic range of 0.3-6.0μgmL(-1). The intra-day and inter-day precisions for colistin A and colistin B were below 9.9% and 4.5% relative standard deviations, respectively. The accuracy test results were between 100.2 and 118.4%. The extraction recoveries were between 81.6 and 94.1%. The method was linear over the test range, with a 0.9991 coefficient of determination. The limit of detection was 0.1μgmL(-1). The validated HPLC-FLD method was successfully applied to quantify the colistin concentrations in 2 patient samples for therapeutic drug monitoring.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Sodium hydroxide, ultra dry, powder or crystals, 99.99% trace metals basis
USP
Sodium bicarbonate, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Sodium hydroxide, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Sodium bicarbonate, ReagentPlus®, ≥99.5%, powder
Sigma-Aldrich
Hydrochloric acid, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
Sodium bicarbonate, ACS reagent, ≥99.7%
Sigma-Aldrich
Sodium hydroxide solution, 5.0 M
Sigma-Aldrich
Hydrogen chloride solution, 1.0 M in diethyl ether
Sigma-Aldrich
Sodium hydroxide, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
Sodium hydroxide, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Hydrogen chloride solution, 1.0 M in acetic acid
Sigma-Aldrich
Hydrochloric acid, ACS reagent, 37%
Sigma-Aldrich
Sodium bicarbonate, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99.7%
Sigma-Aldrich
Sodium bicarbonate, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Sodium hydroxide, reagent grade, 97%, powder
Sigma-Aldrich
Hydrochloric acid, ACS reagent, 37%
Sigma-Aldrich
Hydrogen chloride solution, 2.0 M in diethyl ether
Sigma-Aldrich
Sodium hydroxide, reagent grade, 97%, flakes
Sigma-Aldrich
Hydrochloric acid, 37 wt. % in H2O, 99.999% trace metals basis
Sigma-Aldrich
Tetrahydrofuran, contains 200-400 ppm BHT as inhibitor, ACS reagent, ≥99.0%
Sigma-Aldrich
Hydrogen chloride solution, 4.0 M in dioxane
Sigma-Aldrich
Sodium hydroxide, beads, 16-60 mesh, reagent grade, 97%
Sigma-Aldrich
Tetrahydrofuran, ACS reagent, ≥99.0%, contains 200-400 ppm BHT as inhibitor
Sigma-Aldrich
Sodium hydroxide solution, 50% in H2O
Sigma-Aldrich
Wodorowęglan sodu, −40-+140 mesh, ≥95%
Sigma-Aldrich
Tetrahydrofuran, inhibitor-free, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Daptomycin, cyclic lipopeptide antibiotic
Supelco
Sodium hydroxide concentrate, 0.1 M NaOH in water (0.1N), Eluent concentrate for IC
Sigma-Aldrich
Boric acid-11B, ≥99 atom % 11B