Przejdź do zawartości
Merck
  • Determination of trace acrylamide in starchy foodstuffs by HPLC using a novel mixed-mode functionalized calixarene sorbent for solid-phase extraction cleanup.

Determination of trace acrylamide in starchy foodstuffs by HPLC using a novel mixed-mode functionalized calixarene sorbent for solid-phase extraction cleanup.

Journal of agricultural and food chemistry (2014-06-17)
Wenfen Zhang, Zhifen Deng, Wenjie Zhao, Ling Guo, Wei Tang, Huifang Du, Lin Lin, Qiong Jiang, Ajuan Yu, Lijun He, Shusheng Zhang
ABSTRAKT

In this paper, a rapid and effective HPLC method, using tetraazacalix[2]arene[2]triazine-modified silica gel (NCSi) as solid-phase extraction (SPE) sorbent, was developed for the purification and determination of trace acrylamide in starchy foodstuffs. The main influence factors of SPE including amount of NCSi sorbent, sample flow rate, and volume and composition of washing solution were investigated and evaluated in the sample pretreatment step. The optimized purification effect was achieved at the sample flow rate of 3 mL/min with 100 mg of NCSi and 2 mL of washing solution (water, 100%). The HPLC separation was carried out on a C18 column (250×4.6 mm i.d., 5 μm) with a mobile phase of methanol/water (10:90, v/v). The linear range of the calibration curve was 4-4000 ng/mL with s correlation coefficient of >0.9999. The intraday and interday RSDs (n=5) of peak areas of acrylamide were 0.22 and 0.90% and the intraday and interday RSDs (n=5) of retention times were 0.50 and 1.63%, respectively. In addition, overall recoveries through the extraction and NCSi-SPE purification ranged from 73.13 to 98%. Compared with the commercial SPE sorbents, NCSi featured excellent selectivity to retain polar and nonpolar interferences in the sample matrices. The improved method was simple, rapid, accurate, and promising for the determination of trace acrylamide in starchy foods with a complex matrix.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
Hexane, analytical standard
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Hexane, suitable for HPLC, ≥95%
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Hexane, ReagentPlus®, ≥99%
Sigma-Aldrich
Hexane, Laboratory Reagent, ≥95%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
USP
Rozpuszczalnik resztkowy klasy 2 - acetonitryl, United States Pharmacopeia (USP) Reference Standard
USP
Alkohol metylowy, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Supelco
Methanol, analytical standard
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material