Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
1 ea | Fecha estimada de envío23 de noviembre de 2026 | $9,670.00 |
Acerca de este artículo
$9,670.00
Fecha estimada de envío23 de noviembre de 2026Detalles
Quality Segment
material
TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)
feature
holdup volume 227 mL (in feed channel)
manufacturer/tradename
Pellicon®
parameter
30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C
technique(s)
analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)
H
4.1 cm (1.63 in.)
L
20.6 cm (8.1 in.)
W
17.8 cm (7 in.)
filtration area
1.14 m2
membrane area
1.14 m2
gravimetric extractables
≤1500 mg/m2
matrix
Ultracel® (Membrane)
pore size
30 kDa NMWCO
pH
2-13
General description
La casete Pellicon® 3 con membrana Ultracel® está diseñada para la filtración de proteínas terapéuticas (como anticuerpos monoclonales) y proteínas recombinantes y no recombinantes.
Este dispositivo de ultrafiltración P3C030D10 Pellicon® 3 se caracteriza por un tamaño de poro de NMWCO de 30 kDa, una superficie de filtración de 1,14 m2, una membrana PLCTK y dimensiones de 2,6 cm (Al) x 17,8 cm (An) x 20,6 cm (L).
Features and Benefits
- Robustas y fiables: ideales para los procesos de filtración más exigentes de hoy en día
- Alto rendimiento: producen una excelente resolución, rendimientos y resistencia a la contrapresión
- Recuperación óptima del producto gracias a la probada tecnología de membrana
- Tecnología libre de huecos: membranas sin huecos de última generación resuelven prácticamente cualquier desafío de separación
- Adhesión superior, sin defectos: Ultracel® utiliza membranas compuestas moldeadas sobre un sustrato microporoso
- Fabricación automatizada: ofrece un rendimiento, una uniformidad y una fiabilidad insuperables
- Cuidado e instalación fáciles: fácil de instalar y mantener
Analysis Note
Other Notes
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| description filtration area 1.14 m2, NMWCO 30 kDa | description filtration area 0.11 m2, NMWCO 30 kDa | description filtration area 0.57 m2, NMWCO 30 kDa | description filtration area 1.14 m2, NMWCO 30 kDa |
| pore size 30 kDa NMWCO | pore size 30 kDa NMWCO | pore size 30 kDa NMWCO | pore size 30 kDa NMWCO |
| filtration area 1.14 m2 | filtration area 0.11 m2 | filtration area 0.57 m2 | filtration area 1.14 m2 |
| technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable | technique(s) buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration) |
| matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) |
| material composite regenerated cellulose (CRC) , TPE seal, stainless steel cap (for end; polypropylene-encapsulated), polypropylene screen | material TPE seal, composite regenerated cellulose (CRC) , polypropylene cap (for end), polypropylene screen | material TPE seal, polypropylene screen, composite regenerated cellulose (CRC) , stainless steel cap (for end; polypropylene-encapsulated) | material TPE seal, stainless steel cap (for end; polypropylene-encapsulated), composite regenerated cellulose (CRC) , polypropylene screen |
| parameter 6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C | parameter 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 6.9 bar max. inlet pressure (100 psi), 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate |
Still not finding the right product?
Explore all of our products under Placa Pellicon® 3 con membrana Ultracel®
Clase de almacenamiento
10 - Combustible liquids
wgk
WGK 2
Cumpla las GMP con el programa Emprove®.
Acelere la cualificación, mantenga la conformidad y ahorre tiempo con Emprove® Dossiers.
Nota: será redirigido a EmproveSuite.com. Su nombre de usuario y contraseña son independientes de SigmaAldrich.com y pueden diferir.
Regístrese gratis y acceda a Emprove® Dossiers en cuestión de minutos. Actualice su plan de suscripción para desbloquear contenidos avanzados y personalizados en la Emprove® Suite
¿No encuentra lo que busca? Visite la página de ayuda del programa Emprove®..
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
¿Le resulta difícil encontrar su producto o lote/número de lote?
Cómo encontrar el número de producto
Las referencias de los producto se combinan con los tamaños de envase y las cantidades cuando se muestran en la página web, por ejemplo: T1503-25G. Asegúrese de introducir el número de producto ÚNICAMENTE en el campo del Número de producto (ejemplo: T1503).
Ejemplo:
Otros ejemplos
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
introducir como 1.000309185)
¿Tienes problemas? Siéntase libre de contactar Servicio técnico para asistencia