Saltar al contenido
MilliporeSigma

A novel method for characterization and comparison of reversed-phase column selectivity.

Journal of chromatography. A (2014-08-27)
Jixia Wang, Chaoran Wang, Zhimou Guo, Xuefang Dong, Yuansheng Xiao, Xingya Xue, Xiuli Zhang, Xinmiao Liang
RESUMEN

Characterization of reverse-phase column selectivity is helpful for chromatographers to select an optimal column. A novel method, based on linear solvation energy relationships (LSERs) combined with fundamental retention equations, was developed to characterize and compare reversed-phase column selectivity. The retention times of 25 elaborately selected solutes on 12 reversed-phase columns were determined in three linear gradient elutions. Using these retention times, fundamental retention equations were acquired by a complex sample analysis software system (CSASS). When 0%, 10%, 20%, 30%, 40% and 50% acetonitrile were introduced into the fundamental retention equations, the corresponding retention factors were predicted and used to obtain LSER equations by multiple linear regression. In the gradient elution, the retention times of solutes could be accurately determined and the excessively long or short analysis time could be avoided. As the retention factor (lnkw) at a hypothetical 0% organic modifier closely reflected properties of columns, coefficients of LSERs equations obtained based on lnkw were employed to discuss the properties of different stationary phases. An angle and a spider diagram based on solvation energy vectors were used to compare selectivity differences between stationary phases, which provided a visual means for users to select appropriate columns with orthogonal or similar selectivity. These results of column selectivities were compared with those obtained by geometric orthogonality approach, and a consistent result was acquired. Finally, Click TE-CD and XCharge C18PN with highest difference in column selectivity were applied to the separation of Psoralea corylifolia extraction.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Alcohol etílico puro 200, Molecular Biology
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Alcohol etílico puro, 200 proof
Sigma-Aldrich
Ácido fórmico, reagent grade, ≥95%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, meets USP testing specifications
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Ácido fórmico, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Alcohol etílico puro 190, for molecular biology
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ácido fórmico, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Alcohol etílico puro, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Metanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥88%
Sigma-Aldrich
Etanol, ACS reagent, prima fine spirit, without additive, F15 o1
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Acetonitrilo, suitable for HPLC-GC, ≥99.8% (GC)