Saltar al contenido
MilliporeSigma
  • Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography.

Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography.

Journal of chromatography. A (2015-08-01)
Xiaomei Liu, Zhiwei Sun, Guang Chen, Wanwan Zhang, Yiping Cai, Rongmei Kong, Xiaoyan Wang, Yourui Suo, Jinmao You
RESUMEN

In this study, the magnetic Zeolitic Imidazolate Framework-8 (ZIF-8) microspheres were successfully synthesized and applied as an effective sorbent for preconcentration of several typical phthalate esters (PAEs) from environmental water samples. Firstly, the solvothermal treatment method was used for preparation of Fe3O4 nanoparticles. Then, mercaptoacetic acid (MAA) was served as the functionalized chemical to modify Fe3O4 nanoparticles. The Fe3O4@ZIF-8 core-shell microspheres were synthesized through coating the MAA-capped Fe3O4 nanoparticles with ZIF-8. By coupling magnetic solid-phase extraction (MSPE) with high-performance liquid chromatography (HPLC), a reliable, sensitive and cost-effective method for simultaneous determination of five main PAEs including dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP), and dioctyl phthalate (DOP) was developed. Good linearity was observed in the range of 1.0-100.0μg/L. The limits of detection (S/N=3) and limits of quantification (S/N=10) were in the range of 0.08-0.24 and 0.3-0.8μg/L, respectively. The relative standard deviations were less than 5.5% and the accuracies of the method for the PAEs were in the range from 85.6% to 103.6%. Finally, the Fe3O4@ZIF-8 was successfully applied for rapid extraction of trace amounts of PAEs in environmental water samples.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Tolueno, anhydrous, 99.8%
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Dietilpirocarbonato, 96% (NT)
Sigma-Aldrich
Dibutyl phthalate, 99%
Sigma-Aldrich
Dioctyl phthalate, ≥99.5%
Sigma-Aldrich
Dess-Martin periodinane, 97%
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Diethyl phthalate, 99.5%
Sigma-Aldrich
Fosfato de sodio dibasic dodecahydrate, BioXtra, ≥99.0% (T)
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Acetonitrilo, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Dietilpirocarbonato, 96% (NT)
Sigma-Aldrich
Benzyl butyl phthalate, 98%
Sigma-Aldrich
Dimethyl phthalate, ≥99%
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Dietilpirocarbonato, 96% (NT)
Sigma-Aldrich
Metanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Diethyl phthalate, ≥99%
Supelco
Acetonitrilo, HPLC grade, ≥99.93%
Sigma-Aldrich
Metanol, SAJ special grade
Sigma-Aldrich
Dioctyl phthalate, ≥98.0% (GC)
Sigma-Aldrich
Tolueno, SAJ first grade, ≥99.0%
Sigma-Aldrich
Dimethyl phthalate, ≥99%
Sigma-Aldrich
Metanol, suitable for HPLC
Sigma-Aldrich
Fosfato de sodio dibasic dodecahydrate, JIS special grade, ≥99.0%
Sigma-Aldrich
Acetonitrilo, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Tolueno, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrilo, ≥99.8%, suitable for residue analysis, JIS 300