Direkt zum Inhalt
Merck

Fortfahren mit

2500

ReBlot Plus Kit

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Größe auswählen

Ansicht ändern
Größe/SKUVerfügbarkeitPreis

Über diesen Artikel

eCl@ss:
32161000
UNSPSC Code:
12161503
NACRES:
NA.56
Preise und Verfügbarkeit sind derzeit nicht verfügbar.
Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten


Quality Segment

manufacturer/tradename

Chemicon®, Re-Blot

technique(s)

western blot: suitable

detection method

chemiluminescent

shipped in

wet ice

General description

Western blotting is a commonly used technique for studying protein function and localization. Typically, protein samples are electrophoresed on SDS-PAGE and transferred to a membrane such as nitrocellulose or nylon, where they are probed with specific antibodies. Unlike nucleic acid based technologies, which allow reuse of Southern and Northern blots, it has been difficult to reuse Western blots.

Stripping and reprobing of Western blots offers several advantages:

1) Conservation of samples that are expensive or available only in limited quantities,

2) Analysis of a given blot using several different antibodies, e.g. subtype- or isoform-specific antibodies,

3) Reanalysis of anomalous results and confirmation with the same or a different antibody,

4) Correcting errors in incubation with the wrong antibody,

5) Cost savings in reagents and time by reusing the same blot.

While antigen and antibody based immunoaffinity matrices, such as Sepharose conjugates, have been reused many times without compromising antigen-antibody reactivity, the need for pH extremes and chaotropic agents has precluded the application of these methods to Western blotting.

The MILLIPORE Re-Blot Plus Western Blot Recycling Kit contains specially formulated solutions that quickly and effectively remove antibodies from Western blots without significantly affecting the immobilized proteins.

Advantages of the Re-Blot Plus Western Blot Recycling Kit include:

  • No pungent smelling β-mercaptoethanol is contained in the Antibody Stripping Solution.
  • Antibody stripping is done at room temperature. No heating of blots is required.
  • Blots can be stripped of antibodies in approximately 15 minutes at room temperature.
  • Blots may be reused in 25 minutes.

Application

The MILLIPORE Re-Blot Plus Western Blot Recycling Kit is effective for removal of antibodies from Western blots that have been developed with chemiluminescence or radioactive iodine or other isotopes. It is not recommended for stripping colorimetric substrates (TMB, DAB, 4-chloronapthol, etc.), as it is not possible to effectively remove substrates that precipitate at the reaction site.

The Re-Blot Plus Western Blot Recycling Kit should be used only for qualitative purposes until it has been established by comparative blot analysis that stripping does not quantitatively affect a given antigen.

This product is for research use only; not for diagnostic or in vivo use.

Preparation Note

Kit components should be stored at 4°C upon arrival. Product is stable for 3 to 6 months after receipt. If Antibody Stripping Solution crystallizes upon storage, it may be re-dissolved with gentle warming at 37°C before use.

Note: To prevent reagent degradation secure the cap tightly upon storage. Avoid extended exposure to air.

Other Notes

Mild Antibody Stripping Solution (10x) - (1 container, 50 mL).

Strong Antibody Stripping Solution (10x) - (1 container, 50 mL).

Legal Information

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Re-Blot is a trademark of Merck KGaA, Darmstadt, Germany
Sepharose is a trademark of Cytiva

Ähnliche Artikel vergleichen

Vollständigen Vergleich anzeigen

Unterschiede anzeigen

1 of 1

Dieser Artikel
2502WB59Z742096
description

-

description

-

description

This Western-Re-Probe Reagent is validated for use in Immunoblotting.

description

clear, size 7.3 cm × 3.0 cm × 1.9 cm, pk of 5

technique(s)

western blot: suitable

technique(s)

western blot: suitable

technique(s)

-

technique(s)

-

detection method

chemiluminescent

detection method

chemiluminescent

detection method

-

detection method

-

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

-

manufacturer/tradename

Re-Blot, Chemicon®

manufacturer/tradename

Chemicon®, Re-Blot

manufacturer/tradename

Calbiochem®

manufacturer/tradename

-

Quality Level

100

Quality Level

-

Quality Level

100

Quality Level

-


Signalwort

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Lagerklasse

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects



Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen




Questions

Reviews

No rating value

Active Filters