Fortfahren mit
Größe auswählen
| Größe/SKU | Verfügbarkeit | Preis |
|---|
Über diesen Artikel
Quality Segment
material
polycarbonate connector, polycarbonate container, polypropylene body, silicone tubing
sterility
sterile; γ-irradiated
product line
NovaSeptum® SURe
storage condition
room temperature
parameter
0.50 bar max. pressure (7.25 psi), 4-40 °C temp. range (39-104 °F)
volume
5 mL (20 mL)
fitting
inlet connection (Silicone), Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site)
application(s)
sterile sampling
General description
This product comes as a manifolded unit with accurate volume syringes and connects via AseptiQuik® S connector. The syringes enable sampling for small, accurate volumes, which is particularly important for sampling of high value products. The closed design ensures your sample will be isolated from point of sample to analysis, reducing the risk of losing valuable product and maintaining the integrity of your fluid samples.
Application
Features and Benefits
- Product design ensures process integrity and a representative sample from single-use manufacturing processes
- Industry-standard aseptic connection and disconnection for easy integration into your single-use process
- Other container options available: bags, bottles, syringes, and conical tubes
- Stocked and ready-to-ship for fast delivery
Packaging
- 5 units per box (5*5mL)
- 4 units per box (5*20mL)
Preparation Note
Analysis Note
Other Notes
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description Manifold (5-valve) with AseptiQuik® S connector, sterile; γ-irradiated, volume 5 mL (20 mL) | description Manifold (5-valve) with Inlet C-Flex® Tubing, sterile; β-irradiated, volume 5 mL (20 mL) | description Manifold (3-valve) with Inlet C-Flex® Tubing, sterile; γ-irradiated, volume 5 mL & 20 mL | description Manifold (3-valve) with AseptiQuik® S connector, sterile; γ-irridiated, volume 5 mL & 20 mL |
| fitting outlet connection (containing a male, female and an injection site), inlet connection (Silicone), Luer-Lok® outlet connection (3-piece) | fitting outlet connection (containing a male, female and an injection site), Luer-Lok® inlet connection (3-piece), inlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3-piece) | fitting Luer-Lok® outlet connection (3-piece), Luer-Lok® inlet connection (3-piece), outlet connection (containing a male, female and an injection site), inlet connection (containing a male, female and an injection site) | fitting inlet connection (Silicone), outlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3 piece) |
| product line NovaSeptum® SURe | product line NovaSeptum® SURe | product line NovaSeptum® SURe | product line NovaSeptum® SURe |
| material polycarbonate connector, polypropylene body, silicone tubing, polycarbonate container | material C-Flex tubing, polycarbonate container, silicone tubing, polycarbonate body, polycarbonate Luer lock | material polycarbonate container, silicone tubing, polycarbonate body, polycarbonate clip, polycarbonate cannula, polycarbonate Luer lock, C-Flex tubing | material polycarbonate clip, silicone tubing, polycarbonate body, polycarbonate container, polycarbonate cannula, polycarbonate connector |
| parameter 0.50 bar max. pressure (7.25 psi), 4-40 °C temp. range (39-104 °F) | parameter -80-50 °C temp. range (-112-122 °F), 0.50 bar max. pressure (7.25 psi) | parameter -80-50 °C temp. range (-112-122 °F), 0.5 bar max. pressure (7.25 psi) | parameter 0.5 bar max. pressure (7.25 psi), 4-40 °C temp. range (39-104 °F) |
| storage condition room temperature | storage condition room temperature | storage condition room temperature | storage condition room temperature |
| application(s) sterile sampling | application(s) sterile sampling | application(s) sterile sampling | application(s) sterile sampling |
Still not finding the right product?
Explore all of our products under NovaSeptum® SURe Accurate Volume Syringe Sampling Unit
Bleiben Sie mit dem Emprove®-Programm GMP-konform
Beschleunigen Sie die Qualifizierung, halten Sie die Vorschriften ein und sparen Sie Zeit mit Emprove® Dossiers.
Hinweis: Sie werden zu EmproveSuite.com weitergeleitet. Ihr Benutzername und Passwort sind von SigmaAldrich.com getrennt und können abweichen.
Registrieren Sie sich kostenlos und erhalten Sie innerhalb weniger Minuten Zugang zu Emprove® Dossiers. Aktualisieren Sie Ihr Abonnement, um erweiterte und angepasste Inhalte in der Emprove® Suite freizuschalten.
Sie finden nicht, was Sie suchen? Besuchen Sie die Emprove® Programm-Hilfeseite.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Können Sie Ihr Produkt oder Ihre Lot-/Chargennummer nicht finden?
So finden Sie die Produktnummer
Produktnummern werden bei der Anzeige auf der Website mit Packungsgrößen/-menge kombiniert (Beispiel: T1503-25G). Bitte stellen Sie sicher NUR die Produktnummer in das Feld Produktnummer eingeben (Beispiel: T1503).
Beispiel:
Weitere Beispiele:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
eingeben als 1.000309185)
Haben Sie Probleme? Sie können sich jederzeit an uns wenden Technischer Dienst zur Unterstützung