Quality Segment
material
TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen
feature
holdup volume 3.6 mL (in feed channel)
manufacturer/tradename
Pellicon®
parameter
2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C
technique(s)
analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)
H
0.8 cm (0.33 in.)
L
20.6 cm (8.1 in.)
W
5.6 cm (2.2 in.)
filtration area
88 cm2
membrane area
88 cm2
gravimetric extractables
≤1500 mg/m2
matrix
Ultracel® (Membrane)
pore size
30 kDa NMWCO
pH
2-13
shipped in
ambient
General description
Die Pellicon® 3 Kassetten mit Ultracel® Membran sind für die Filtration therapeutischer Proteine (wie monoklonaler Antikörper) sowie rekombinanter und nicht-rekombinanter Proteine konzipiert.
Diese P3C030D00 Pellicon® 3 Utrafiltrationseinheit hat eine Porengröße von 30 kDa NMWCO, eine Filtrationsfläche von 88 cm2, eine PLCTK-Membran und die Maße 3,8 cm (H) x 17,8 cm (B) x 20,6 cm (L).
Features and Benefits
- Robust und zuverlässig – ideal für die heutigen anspruchsvolleren Filtrationsprozesse
- Hohe Leistungsfähigkeit – exzellente Auflösung, Ausbeute und Beständigkeit gegen Rückstau
- Optimale Produktrückgewinnung – dank bewährter Membrantechnologie
- Technologie für blasenfreie Strukturen – erstklassige Membranen für nahezu jede Trennungsherausforderung
- Fehlerfreie, ausgezeichnete Adhäsion – Ultracel®enthält Verbundmembranen auf einem mikroporösen Substrat
- Automatisierte Herstellung – bietet unschlagbare Leistungsfähigkeit, Konsistenz und Zuverlässigkeit
- Einfache Installation und Instandhaltung – einfach aufzubauen und zu warten
Analysis Note
Other Notes
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 3.6 mL (in feed channel) | description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 1.5 mL (in feed channel) | description filtration area 88 cm2, NMWCO 5 kDa | description filtration area 0.11 m2, NMWCO 30 kDa |
| pore size 30 kDa NMWCO | pore size 30 kDa NMWCO | pore size 5 kDa NMWCO | pore size 30 kDa NMWCO |
| filtration area 88 cm2 | filtration area 88 cm2 | filtration area 88 cm2 | filtration area 0.11 m2 |
| technique(s) analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable | technique(s) protein purification: suitable (concentration), buffer exchange: suitable, analytical sample preparation: suitable | technique(s) buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) |
| matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) |
| material composite regenerated cellulose (CRC) membrane, polypropylene cap (for end), TPE seal, polypropylene screen | material TPE seal, polypropylene screen, polypropylene cap (for end), composite regenerated cellulose (CRC) membrane | material TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene cap (for end), polypropylene screen | material composite regenerated cellulose (CRC) , TPE seal, polypropylene cap (for end), polypropylene screen |
| parameter 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate, 2.75 bar max. inlet pressure (40 psi) at 50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours) | parameter 4-6 L/min-m2 recirculation rate, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 40 psi max. transmembrane pressure at 4-50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 2.75 bar max. inlet pressure (40 psi) at 50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 5.5 bar max. inlet pressure (80 psi) at 40 °C, 4-6 L/min-m2 recirculation rate, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 80 psi max. transmembrane pressure at 4-40 °C, 6.9 bar max. inlet pressure (100 psi), 40 psi max. transmembrane pressure at 4-50 °C, 2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours) | parameter 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 4-6 L/min-m2 recirculation rate |
Still not finding the right product?
Explore all of our products under Pellicon® 3-Kassette mit Ultracel® 30-kDa-Membran, D-Screen, 88 cm2
Lagerklasse
10 - Combustible liquids
wgk
WGK 2
Zulassungslistungen
Zulassungslistungen werden hauptsächlich für chemische Produkte erstellt. Für nicht-chemische Produkte können hier nur begrenzte Angaben gemacht werden. Kein Eintrag bedeutet, dass keine der Komponenten gelistet ist. Es liegt in der Verantwortung des Benutzers, die sichere und legale Verwendung des Produkts zu gewährleisten.
64-19-7
Bleiben Sie mit dem Emprove®-Programm GMP-konform
Beschleunigen Sie die Qualifizierung, halten Sie die Vorschriften ein und sparen Sie Zeit mit Emprove® Dossiers.
Hinweis: Sie werden zu EmproveSuite.com weitergeleitet. Ihr Benutzername und Passwort sind von SigmaAldrich.com getrennt und können abweichen.
Registrieren Sie sich kostenlos und erhalten Sie innerhalb weniger Minuten Zugang zu Emprove® Dossiers. Aktualisieren Sie Ihr Abonnement, um erweiterte und angepasste Inhalte in der Emprove® Suite freizuschalten.
Sie finden nicht, was Sie suchen? Besuchen Sie die Emprove® Programm-Hilfeseite.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Können Sie Ihr Produkt oder Ihre Lot-/Chargennummer nicht finden?
So finden Sie die Produktnummer
Produktnummern werden bei der Anzeige auf der Website mit Packungsgrößen/-menge kombiniert (Beispiel: T1503-25G). Bitte stellen Sie sicher NUR die Produktnummer in das Feld Produktnummer eingeben (Beispiel: T1503).
Beispiel:
Weitere Beispiele:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
eingeben als 1.000309185)
Haben Sie Probleme? Sie können sich jederzeit an uns wenden Technischer Dienst zur Unterstützung