Direkt zum Inhalt
Merck

Early hysteroscopic removal of intratubal microinserts with urologic stone retrieval forceps.

Obstetrics and gynecology (2014-07-09)
Lisa M Goldthwaite, Lindsay Edwards, Kristina Tocce
ZUSAMMENFASSUNG

Nickel hypersensitivity reactions can be an indication for the removal of intratubal microinserts used for hysteroscopic sterilization. Although early removal can be attempted hysteroscopically, hysteroscopic grasping forceps may be inadequate to grasp deeply positioned inserts. Three days after hysteroscopic sterilization, the patient presented with a rash consistent with a nickel hypersensitivity reaction. Ten days after placement, we successfully performed hysteroscopic removal of an intratubal microinsert with tri-prong urologic stone retrieval forceps after standard hysteroscopic grasping forceps was unable to reach the deeply positioned device. Within 36 hours of bilateral microinsert removal, all symptoms resolved. In difficult cases, 1-mm tri-prong urologic stone retrieval forceps can be useful for early hysteroscopic removal of intratubal microinserts.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 2800, slurry, in H2O, active catalyst
Sigma-Aldrich
Nickel, powder, <50 μm, 99.7% trace metals basis
Sigma-Aldrich
Nickel, nanopowder, <100 nm avg. part. size, ≥99% trace metals basis
Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 2400, slurry, in H2O, active catalyst
Sigma-Aldrich
Nickel, powder, <150 μm, 99.99% trace metals basis
Sigma-Aldrich
Nickel, foil, thickness 0.125 mm, ≥99.9%
Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 4200, slurry, in H2O, active catalyst
Nickel, rod, 100mm, diameter 1.5mm, 99.99+%
Sigma-Aldrich
Nickel, foil, thickness 0.5 mm, 99.98% trace metals basis
Sigma-Aldrich
Nickel, powder, <1 μm, 99.8% trace metals basis
Sigma-Aldrich
Nickel, wire, diam. 0.25 mm, ≥99.9%
Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 3202, slurry, in H2O, active catalyst
Sigma-Aldrich
Nickel, rod, diam. 6.35 mm, ≥99.99% trace metals basis
Nickel, pellets, 100g, max. size 10mm, 99.999%
Sigma-Aldrich
Nickel, wire, diam. 0.5 mm, ≥99.9% trace metals basis
Nickel, mesh, 30x30mm, nominal aperture 0.34mm, thickness 0.025mm, wire diameter 0.041mm, 70 wires/inch, open area 80%, electro-formed mesh, 99.9%
Sigma-Aldrich
Nickel, wire, diam. 0.5 mm, ≥99.99% trace metals basis
Sigma-Aldrich
Nickel, foil, thickness 0.1 mm, 99.98% trace metals basis
Sigma-Aldrich
Nickel, sputtering target, diam. × thickness 2.00 in. × 0.25 in., 99.95% trace metals basis
Nickel, foil, 100x100mm, thickness 1.6mm, 99%
Sigma-Aldrich
Nickel, foil, thickness 0.25 mm, 99.995% trace metals basis
Nickel, foil, light tested, 150x150mm, thickness 0.025mm, 99.9%
Nickel, mesh, 100x250mm, nominal aperture 0.73mm, wire diameter 0.25mm, 26x26 wires/inch, open area 55%, plain weave mesh, 99%
Nickel, pellets, 100g, max. size 5mm, 99.99+%
Nickel, wire reel, 100m, diameter 0.025mm, as drawn, 99.98%
Nickel, mesh, 65x65mm, nominal aperture 0.34mm, thickness 0.025mm, wire diameter 0.041mm, 70 wires/inch, open area 80%, electro-formed mesh, 99.9%
Nickel, foil, 100x100mm, thickness 0.1mm, annealed, 99%
Nickel, mesh, 130x130mm, nominal aperture 0.04mm, thickness 0.004mm, wire diameter 0.011mm, 500 wires/inch, open area 60%, electro-formed mesh, 99.9%
Nickel, sphere, 100pcs, diameter 1.0mm, precision sphere grade 200, 99%
Nickel, mesh, 120x120mm, nominal aperture 0.43mm, thickness 0.004mm, wire diameter 0.067mm, 51 wires/inch, open area 75%, electro-formed mesh, 99.9%