Direkt zum Inhalt
Merck
  • Multiple system organ response induced by hyperoxia in a clinically relevant animal model of sepsis.

Multiple system organ response induced by hyperoxia in a clinically relevant animal model of sepsis.

Shock (Augusta, Ga.) (2014-07-01)
Raquel Rodríguez-González, José Luis Martín-Barrasa, Ángela Ramos-Nuez, Ana María Cañas-Pedrosa, María Teresa Martínez-Saavedra, Miguel Ángel García-Bello, Josefina López-Aguilar, Aurora Baluja, Julián Álvarez, Arthur S Slutsky, Jesús Villar
ZUSAMMENFASSUNG

Oxygen therapy is currently used as a supportive treatment in septic patients to improve tissue oxygenation. However, oxygen can exert deleterious effects on the inflammatory response triggered by infection. We postulated that the use of high oxygen concentrations may be partially responsible for the worsening of sepsis-induced multiple system organ dysfunction in an experimental clinically relevant model of sepsis. We used Sprague-Dawley rats. Sepsis was induced by cecal ligation and puncture. Sham-septic controls (n = 16) and septic animals (n = 32) were randomly assigned to four groups and placed in a sealed Plexiglas cage continuously flushed for 24 h with medical air (group 1), 40% oxygen (group 2), 60% oxygen (group 3), or 100% oxygen (group 4). We examined the effects of these oxygen concentrations on the spread of infection in blood, urine, peritoneal fluid, bronchoalveolar lavage, and meninges; serum levels of inflammatory biomarkers and reactive oxygen species production; and hematological parameters in all experimental groups. In cecal ligation and puncture animals, the use of higher oxygen concentrations was associated with a greater number of infected biological samples (P < 0.0001), higher serum levels of interleukin-6 (P < 0.0001), interleukin-10 (P = 0.033), and tumor necrosis factor-α (P = 0.034), a marked decrease in platelet counts (P < 0.001), and a marked elevation of reactive oxygen species serum levels (P = 0.0006) after 24 h of oxygen exposure. Oxygen therapy greatly influences the progression and clinical manifestation of multiple system organ dysfunction in experimental sepsis. If these results are extrapolated to humans, they suggest that oxygen therapy should be carefully managed in septic patients to minimize its deleterious effects.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Aluminiumoxid, standard grade, Brockmann I, activated, basic
Sigma-Aldrich
Aluminiumoxid, activated, Brockmann I, standard grade, neutral
Sigma-Aldrich
Ethylendiamintetraessigsäure, ACS reagent, 99.4-100.6%, powder
Sigma-Aldrich
Ethylendiamintetraessigsäure, anhydrous, crystalline, BioReagent, suitable for cell culture
Sigma-Aldrich
Ethylendiamintetraessigsäure -Lösung, 0.02% in DPBS (0.5 mM), sterile-filtered, BioReagent, suitable for cell culture
Sigma-Aldrich
Ethylendiamintetraessigsäure Dinatriumsalz -Lösung, BioUltra, pH 8.0, ~0.5 M in H2O
Sigma-Aldrich
Aluminiumoxid, powder, primarily α phase, ≤10 μm avg. part. size, 99.5% trace metals basis
Sigma-Aldrich
Aluminiumoxid, Brockmann I, standard grade, activated, acidic
Sigma-Aldrich
Aluminiumoxid, nanopowder, <50 nm particle size (TEM)
Sigma-Aldrich
Ethylendiamintetraessigsäure, 99.995% trace metals basis
Sigma-Aldrich
Ethylendiamintetraessigsäure, BioUltra, anhydrous, ≥99% (titration)
Sigma-Aldrich
Aluminiumoxid, powder, 99.99% trace metals basis
Sigma-Aldrich
Aluminiumoxid, nanoparticles, <50 nm particle size (DLS), 20 wt. % in isopropanol
Sigma-Aldrich
Aluminiumoxid, nanopowder, 13 nm primary particle size (TEM), 99.8% trace metals basis
Sigma-Aldrich
Aluminiumoxid, fused, powder, primarily α-phase, -325 mesh
Sigma-Aldrich
Ethylendiamintetraessigsäure, purified grade, ≥98.5%, powder
Sigma-Aldrich
Aluminiumoxid, pellets, 3 mm
Sigma-Aldrich
Aluminiumoxid, Corundum, α-phase, -100 mesh
Supelco
Aluminiumoxid, activated, neutral, Brockmann Activity I
Sigma-Aldrich
Aluminiumoxid, pore size 58 Å, ~150 mesh
Sigma-Aldrich
Aluminiumoxid, fused, powder, primarily α-phase, 100-200 mesh
Sigma-Aldrich
Aluminiumoxid, Type WN-6, Neutral, Activity Grade Super I
Sigma-Aldrich
Aluminiumoxid, nanoparticles, 30-60 nm particle size (TEM), 20 wt. % in H2O
Sigma-Aldrich
Aluminiumoxid, 99.997% trace metals basis
Sigma-Aldrich
Ethylendiamintetraessigsäure, ≥98.0% (KT)
Sigma-Aldrich
Aluminiumoxid, single crystal substrate, <0001>
Sigma-Aldrich
Ethylendiamintetraessigsäure, BioUltra, ≥99.0% (KT)
Sigma-Aldrich
Aluminiumoxid, Brockmann I, standard grade, activated, neutral, free-flowing, Redi-Dri
Sigma-Aldrich
Aluminumoxid, mesoporös, MSU-X (wormhole), average pore size 3.8 nm
Supelco
Aluminiumoxid, for the determination of hydrocarbons