Direkt zum Inhalt
Merck
  • Stability-indicating RP-LC method for determination of azilsartan medoxomil and chlorthalidone in pharmaceutical dosage forms: application to degradation kinetics.

Stability-indicating RP-LC method for determination of azilsartan medoxomil and chlorthalidone in pharmaceutical dosage forms: application to degradation kinetics.

Analytical and bioanalytical chemistry (2014-09-06)
Walid M Ebeid, Ehab F Elkady, Asmaa A El-Zaher, Ramzia I El-Bagary, Gabor Patonay
ZUSAMMENFASSUNG

A RP-LC method was developed and validated for simultaneous determination of the active components, azilsartan medoxomil (AZL) and chlorthalidone (CLT), in their novel antihypertensive combined recipe. The chromatographic separation was achieved on an Eclipse XDB-C18 (4.6 × 150 mm, 5 μm) column using a mobile phase consisting of methanol/potassium hydrogen phosphate buffer (pH 8, 0.05 M) (40:60, v/v) in isocratic mode. The flow rate was maintained at 0.8 mL min(-1) at ambient temperature. Detection was carried out at 210 nm. The method was validated according to the ICH guidelines. Linearity, accuracy, and precision were satisfactory over the concentration range of 5.0-50.0 and 2.5-25.0 μg mL(-1) for AZL and CLT, respectively (r (2) = 0.9999). LODs for AZL and CLT were 0.90 and 0.32 μg mL(-1), whereas LOQs were 2.72 and 0.98 μg mL(-1), respectively. Both drugs were subjected to forced degradation studies under hydrolysis (neutral, acidic, and alkaline), oxidative, and photolytic extensive stress conditions. The proposed method is stability indicating by the resolution of the investigated drugs from their degradation products. Moreover, the kinetics of the acidic degradation of AZL as well as the kinetics of the alkaline degradation of CLT were investigated. Arrhenius plots were constructed and the apparent first-order rate constants, half-life times, shelf-life times, and the activation energies of the degradation processes were calculated. The method was successfully applied for the determination of the studied drugs simultaneously in their coformulated tablet. The developed method is specific and stability indicating for the quality control and routine analysis of the cited medications in their pharmaceutical preparations.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Wasserstoffperoxid -Lösung, contains inhibitor, 30 wt. % in H2O, ACS reagent
Sigma-Aldrich
Wasserstoffperoxid -Lösung, 30 % (w/w) in H2O, contains stabilizer
Sigma-Aldrich
Ammoniumacetat, ACS reagent, ≥97%
Sigma-Aldrich
Ammoniumacetat, ≥99.99% trace metals basis
Supelco
Ammoniumacetat, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Wasserstoffperoxid -Lösung, 50 wt. % in H2O, stabilized
Sigma-Aldrich
Ammoniumacetat, Molecular Biology, ≥98%
Sigma-Aldrich
Wasserstoffperoxid-Lösung, 30% (w/w), puriss. p.a., reag. ISO, reag. Ph. Eur.
Millipore
Wasserstoffperoxid -Lösung, 3%, suitable for microbiology
Sigma-Aldrich
Ammoniumacetat -Lösung, Molecular Biology, 7.5 M
Supelco
Wasserstoffperoxid -Lösung, ≥30%, for trace analysis
Sigma-Aldrich
Wasserstoffperoxid -Lösung, contains ~200 ppm acetanilide as stabilizer, 3 wt. % in H2O
Sigma-Aldrich
Wasserstoffperoxid -Lösung, contains inhibitor, 30 wt. % in H2O, meets USP testing specifications
Sigma-Aldrich
Ammoniumacetat, 99.999% trace metals basis
Sigma-Aldrich
Wasserstoffperoxid -Lösung, contains inhibitor, 35 wt. % in H2O
Sigma-Aldrich
Wasserstoffperoxid -Lösung, purum p.a., ≥35% (RT)
Sigma-Aldrich
Ammoniumacetat, reagent grade, ≥98%
Sigma-Aldrich
Ammoniumacetat, BioXtra, ≥98%
Sigma-Aldrich
Wasserstoffperoxid -Lösung, 34.5-36.5%
Supelco
Wasserstoffperoxid -Lösung, 30 % (w/w), for ultratrace analysis
Sigma-Aldrich
Ammoniumacetat -Lösung, BioUltra, ~5 M in H2O
Sigma-Aldrich
Ammoniumacetat, BioUltra, ≥99.0%
Sigma-Aldrich
Wasserstoffperoxid -Lösung, tested according to Ph. Eur.
Sigma-Aldrich
Ser-Phe-Leu-Leu-Arg-Asn-Pro-Asn-Asp-Lys-Tyr-Glu-Pro-Phe, ≥97% (HPLC)