Scegli un formato
| Voi/SKU | Disponibilità | Prezzo |
|---|---|---|
20 reactions | Per conoscere la disponibilità, visualizza il carrello | CHF 62.30 |
100 reactions | Per conoscere la disponibilità, visualizza il carrello | CHF 273.00 |
400 reactions | Per conoscere la disponibilità, visualizza il carrello | CHF 920.00 |
Informazioni su questo articolo
CHF 62.30
Quality Segment
form
liquid
usage
sufficient for 100 reactions, sufficient for 20 reactions, sufficient for 400 reactions
feature
dNTPs included, hotstart
concentration
2.5 units/reaction (50 μL reaction volume)
technique(s)
RT-qPCR: suitable, qPCR: suitable, whole genome amplification: suitable
color
colorless
input
purified DNA
application(s)
agriculture
compatibility
Bio-Rad MyiQ ( ), Bio-Rad iCycler iQ, Bio-Rad iQ 5, for use with ABI 5700, for use with ABI 7000, for use with ABI 7300, for use with ABI 7500 Fast, for use with ABI 7500, for use with ABI 7700, for use with ABI 7900 Fast, for use with ABI 7900 HT, for use with ABI 7900, for use with ABI StepOne, for use with ABI StepOnePlus, for use with ABI ViiA 7, for use with Bio-Rad CFX384, for use with Bio-Rad CFX96, for use with Bio-Rad MJ Chromo4, for use with Bio-Rad MJ Opticon 2, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Bio-Rad MJ Opticon, for use with Bio-Rad MiniOpticon, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Eppendorf® Mastercycler ep realplex, for use with Illumina Eco qPCR, for use with Qiagen Corbett Rotor-Gene 3000, for use with Qiagen Corbett Rotor-Gene 6000, for use with Qiagen Corbett Rotor-Gene Q, for use with Roche LightCycler 480, for use with Strategene Mx3000P, for use with Strategene Mx3005P, for use with Strategene Mx4000
detection method
probe-based
shipped in
wet ice
storage temp.
−20°C
General description
Application
- per l'amplificazione dell'RNA del virus HIV-1 mediante reazione a catena della polimerasi quantitativa (qPCR) dopo trascrizione inversa a DNA utilizzando delle sonde;
- in un saggio di RT-qPCR in 2 passaggi per quantificare l'RNA dopo trascrizione inversa in uno studio per monitorare l'attività della liquirizia nella differenziazione e nella funzionalità di cellule T-reg;
- come componente della miscela di reazione per l'identificazione e l'amplificazione del DNA di Salmonella sp. e del plasmide pUC 19 come controllo interno dell'amplificazione (IAC);
- come componente della miscela di reazione per l'identificazione del DNA di Clostridium difficile mediante reazione a catena della polimerasi quantitativa (qPCR)
- per la PCR quantitativa real-time dell'mRNA di ß-arrestina-1 (ARRB1) e β-arrestina-2 (ARRB2) dopo trascrizione inversa
Biochem/physiol Actions
Features and Benefits
- Massima praticità: le miscele ReadyMix contengono tutti i componenti necessari per la qPCR; è sufficiente aggiungere la chimica di rilevamento in fluorescenza, i primer e lo stampo.
- Maggiore specificità & incremento della resa del target: la JumpStart™ Taq impedisce l′amplificazione aspecifica e aumenta la resa del target
- Massima flessibilità: adatta per l'uso con diverse tipologie di chimiche di rilevamento, comprese quelle con sonde molecolari e con coloranti che legano il DNA a doppio filamento come SYBR™ Green I.
- Progettata per l′uso con ciclatori termici real-time su piastra/provetta o strumenti capillari
Packaging
Il volume di reazione predefinito è di 50 μL
20RXN confezione da 1 X 500 μL
100RXN confezione da 1 X 2.5 mL
400RXN confezione 1 X 10 mL
Other Notes
Legal Information
Questo prodotto è un kit 5′ Nuclease Core autorizzato L′utilizzo di questo prodotto è coperto dai brevetti USA indicati di seguito e dalle corrispondenti richieste di brevetto al di fuori degli USA: brevetto No. 5,210,015 and 5,487,972. L′acquisto di questo prodotto include un'immunità limitata e non trasferibile dalle azioni giudiziarie ai sensi delle suddette rivendicazioni di brevetto per l'utilizzo limitato a questa quantità di prodotto per la ricerca interna dell'acquirente. L'acquisto separato di una sonda con licenza conferirebbe i diritti ai sensi dei brevetti statunitensi e alle corrispondenti rivendicazioni di brevetto al di fuori degli Stati Uniti: 5,538,848, 5,723,591, 5,876,930, 6,030,787, 6,258,569, 5,804,375 (solo rivendicazioni 1-12) e rivendicazioni al di fuori degli Stati Uniti corrispondenti al brevetto USA n. 6.214.979. Non è espresso esplicitamente, implicitamente o per malafede alcun diritto a qualsiasi altra rivendicazione di brevetto e alcun diritto a prestare servizi commerciali di qualsiasi tipo, inclusa senza limitazioni la comunicazione dei risultati delle attività degli acquirenti dietro pagamento o altro corrispettivo commerciale. Prodotto destinato esclusivamente a scopi di ricerca. Gli usi diagnostici brevettati da Roche richiedono una licenza separata di Roche. Ulteriori informazioni sull'acquisto di licenze possono essere ottenute contattando il Direttore Licenze, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.
1 of 1
Questo articolo | |||
|---|---|---|---|
| description For probe-based real-time PCR | description for quantitative PCR, MgCI2 in buffer | description for quantitative PCR, without MgCl2 in buffer | description One step RT-qPCR for probe-based methods, MMLV & hot-start Taq |
| technique(s) qPCR: suitable, whole genome amplification: suitable, RT-qPCR: suitable | technique(s) qPCR: suitable, RT-qPCR: suitable, whole genome amplification: suitable | technique(s) RT-qPCR: suitable, whole genome amplification: suitable | technique(s) qPCR: suitable, RT-qPCR: suitable, whole genome amplification: suitable |
| feature dNTPs included, hotstart | feature dNTPs included, hotstart | feature dNTPs included, hotstart | feature dNTPs included, hotstart |
| application(s) agriculture | application(s) agriculture | application(s) agriculture | application(s) - |
| concentration 2.5 units/reaction (50 μL reaction volume) | concentration 1.25 units/reaction (50 μL reaction volume) | concentration 1.25 units/reaction (50 μL reaction volume) | concentration - |
| input purified DNA | input purified DNA | input purified DNA | input purified RNA |
| compatibility Bio-Rad MyiQ ( ), for use with Bio-Rad MJ Opticon, for use with ABI StepOnePlus, for use with ABI ViiA 7, for use with Roche LightCycler 480, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Qiagen Corbett Rotor-Gene 3000, for use with ABI 7900, for use with ABI 7300, for use with Bio-Rad CFX96, for use with ABI 7900 HT, for use with ABI 7500, for use with Eppendorf® Mastercycler ep realplex, for use with ABI 7900 Fast, Bio-Rad iCycler iQ, for use with ABI 7700, for use with Qiagen Corbett Rotor-Gene Q, for use with Bio-Rad MiniOpticon, for use with Bio-Rad CFX384, for use with ABI 7000, for use with Bio-Rad MJ Opticon 2, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Strategene Mx3005P, for use with Strategene Mx4000, for use with Qiagen Corbett Rotor-Gene 6000, for use with ABI 7500 Fast, for use with Illumina Eco qPCR, for use with ABI 5700, for use with Bio-Rad MJ Chromo4, Bio-Rad iQ 5, for use with Strategene Mx3000P | compatibility Bio-Rad MiniOpticon, Roche LightCycler 480 , Strategene Mx3005P, ABI ViiA 7 , ABI 7900 HT, Cepheid SmartCycler, Strategene Mx3000P, Bio-Rad iCycler iQ, ABI StepOne, Strategene Mx4000, Bio-Rad MJ Opticon, ABI 7900 HT Fast, ABI StepOnePlus, ABI 7500, for use with ABI 5700, ABI 7500 Fast, Qiagen Corbett Rotor-Gene 3000, Eppendorf® Mastercycler ep realplex , Bio-Rad MJ Chromo4, Bio-Rad CFX384, ABI 7700, ABI 7000, Bio-Rad MyiQ, ABI 7300, Qiagen Corbett Rotor-Gene 6000, Eppendorf® Mastercycler ep realplex2 S, Bio-Rad iQ 5, Bio-Rad MJ Opticon 2 , Illumina Eco qPCR, Qiagen Corbett Rotor-Gene Q, Bio-Rad CFX96 | compatibility Bio-Rad iCycler iQ, for use with ABI 7500, for use with ABI 7000, for use with ABI 7900, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with ABI 7500 Fast, for use with ABI 7300, for use with Bio-Rad CFX384, for use with Illumina Eco qPCR, for use with ABI 5700, for use with ABI ViiA 7, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Strategene Mx4000, for use with Bio-Rad MiniOpticon, for use with Qiagen Corbett Rotor-Gene 6000, for use with Qiagen Corbett Rotor-Gene 3000, for use with Bio-Rad MJ Opticon 2, for use with ABI 7900 Fast, for use with Strategene Mx3000P, for use with Qiagen Corbett Rotor-Gene Q, Bio-Rad MyiQ, for use with ABI StepOne, for use with ABI 7700, for use with ABI 7900 HT, for use with Roche LightCycler 480, for use with Bio-Rad CFX96, for use with ABI StepOnePlus, for use with Bio-Rad MJ Chromo4, for use with Strategene Mx3005P, Bio-Rad iQ 5 | compatibility ABI 7500 Fast, ABI 7900, Strategene Mx3000P, ABI 7000, Bio-Rad iCycler iQ, Eppendorf® Mastercycler ep realplex, Cepheid SmartCycler, Bio-Rad MJ Opticon, ABI 5700, Bio-Rad MJ Opticon 2, Roche LightCycler 480, ABI ViiA 7, ABI 7900 HT Fast, ABI StepOne, Strategene Mx3005P, ABI StepOnePlus, Bio-Rad CFX96, Qiagen Corbett Rotor-Gene Q, Bio-Rad CFX384, Qiagen Corbett Rotor-Gene 3000, Bio-Rad MiniOpticon, Illumina Eco qPCR, Bio-Rad iQ5, Bio-Rad MyiQ, Eppendorf® Mastercycler ep realplex2 s, ABI 7700, Strategene Mx4000, ABI 7300, Bio-Rad MJ Chromo4, Qiagen Corbett Rotor-Gene 6000 |
Parola di avvertenza
Warning
Codici di pericolo
Avvertenze di sicurezza
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1
Classe di stoccaggio
12 - Non Combustible Liquids
Che succede?
WGK 3
Scegli una delle versioni più recenti:
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.





