The control of impurities in amitriptyline hydrochloride using a reversed-phase hybrid stationary phase.

Pharmeuropa scientific notes (2007-08-11)
S P Dixon, A Lodi, J H M Miller, G G Skellern
ABSTRACT

An isocratic reversed-phase liquid chromatographic method is described using a hybrid column for the control of synthetic impurities potentially found in amitriptyline hydrochloride. The method has been validated and is capable of controlling impurities to 0.1 per cent.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Dibenzosuberone, European Pharmacopoeia (EP) Reference Standard