Saltar al contenido
Merck

S9888

Cloruro de sodio

ACS reagent, ≥99.0%

Sodium chloride

Sinónimos:

Halita, sal de roca, NaCl

Iniciar sesiónpara ver los posibles precios especiales de su organización

Seleccione un Tamaño

25 G
$53.700
500 G
$63.200
1 KG
$100.000
2.5 KG
$188.000
5 KG
$264.000
10 KG
$296.000
25 KG
$592.000
50 KG
$819.000

$53.700


Disponible para enviar HOYDetalles


Solicite una orden a granel

Acerca de este artículo

Fórmula lineal:
NaCl
Número CAS:
Peso molecular:
58.44
Beilstein/REAXYS Number:
3534976
EC Number:
MDL number:
UNSPSC Code:
12352302
PubChem Substance ID:
NACRES:
NA.21
Assay:
≥99.0%
Grade:
ACS reagent
Form:
powder

Saltar a

Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

grade

ACS reagent

Quality Level

agency

suitable for EPA 1613
suitable for EPA 300
suitable for GB 5009.253-2016

vapor pressure

1.33 hPa ( 865 °C)

assay

≥99.0%

form

powder

impurities

≤0.005% Insoluble matter

pH

5.0-9.0 (25 °C, 5% in solution)

mp

801 °C (lit.)

anion traces

bromide (Br-): ≤0.01%
chlorate, nitrate (as NO3-): ≤0.003%
iodide (I-): ≤0.002%
phosphate (PO43-): ≤5 ppm
sulfate (SO42-): ≤0.004%

cation traces

Ba:, passes test
Ca: ≤0.002%
Fe: ≤2 ppm
K: ≤0.005%
Mg: ≤0.001%
heavy metals: ≤5 ppm (by ICP-OES)

SMILES string

[Na+].[Cl-]

InChI

1S/ClH.Na/h1H;/q;+1/p-1

InChI key

FAPWRFPIFSIZLT-UHFFFAOYSA-M

¿Está buscando productos similares? Visita Guía de comparación de productos

Categorías relacionadas

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
567440746398S9625
form

powder

form

solid

form

powder

form

powder or crystals

assay

≥99.0%

assay

≥99% (titration)

assay

≥99%

assay

≥99%

Quality Level

200

Quality Level

100

Quality Level

100

Quality Level

200

grade

ACS reagent

grade

ACS reagent

grade

ACS reagent, anhydrous

grade

-

pH

5.0-9.0 (25 °C, 5% in solution)

pH

-

pH

5.0-9.0 (25 °C, 5% in solution)

pH

7

impurities

≤0.005% Insoluble matter

impurities

≤0.005% Insoluble material

impurities

≤0.005% Insoluble matter

impurities

-

Application

El cloruro de sodio se ha utilizado para la preparación de disolución salina tamponada con Tris, disolución salina tamponada con fosfato, tampón de lisis celular MPM-2 (proteína mitótica monoclonal 2), tampón de lavado de inmunoprecipitación, medios LB (Luria-Bertani) y tampón de diálisis.[1][2][3]

Legal Information

Redi-Dri is a trademark of Sigma-Aldrich Co. LLC

Clase de almacenamiento

13 - Non Combustible Solids

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Meng Yuan et al.
Cell host & microbe, 25(6), 873-883 (2019-06-14)
The fusion peptide (FP) of HIV-1 envelope glycoprotein (Env) is essential for mediating viral entry. Detection of broadly neutralizing antibodies (bnAbs) that interact with the FP has revealed it as a site of vulnerability. We delineate X-ray and cryo-electron microscopy
Christopher S Hale et al.
The Review of scientific instruments, 90(3), 034102-034102 (2019-04-01)
The membrane concentration osmometer coupled with multiple sample preparations has been used for over a century to determine a number of colloidal properties. At the dilute region, this method has been used to determine solute molecular mass. When the solution
Immunofluorescent Staining of Mouse Intestinal Stem Cells.
O'Rourke KP et al.
Bio-protocol, 6, e1732-e1732 (2016)
Heterologous expression and purification of catalytic domain of CESA1 from Arabidopsis thaliana.
Vandavasi VG and O?Neill H
Bio-protocol null
MPM-2 Mediated Immunoprecipitation of Proteins Undergoing Proline-directed Phosphorylation.
Antonelli R and Zacchi P
Bio-protocol null

Artículos

Using an Ascentis® Express F5 HPLC column, this study separates 11 β-agonists in pork by LC-MS/MS in under 8 minutes with excellent recovery and precision.

Characterize mAb monomers, aggregates, and fragments using SEC-UV workflow with Zenix® and Zenix®-C SEC columns.

HPLC-UV method detects 9 antioxidants like propyl gallate in food using a Discovery®

Protocolos

SEC-MS protocol for rapid glycoprofiling of monoclonal antibodies with antibody purification and mass spectrometer calibration.

Follow our procedure for the determination of alpha-Amylase activity. This enzymatic assay of a-Amylase guides you through the entire process and necessary calculations.

Protocol for the preparation of Antibody Sensitized Sheep Erythrocytes. Includes product numbers and links.

A complete workflow for the intact and middle-up mass analysis of reduced and non-reduced monoclonal antibodies based on SEC-MS with sample preparation by protein-A affinity clean-up.

Contenido relacionado

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Questions

1–5 of 5 Questions  
  1. How this product is stored?

    1 answer
    1. This product should be stored at room temperature, tightly closed, and in a dry environment.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  4. How is this product opened?

    1 answer
    1. Product S9888-10KG is packaged in a 10 L plastic pail with a lid secured by a tamper-evident seal. The seal is a 1/16 inch diameter steel wire that cannot be cut with scissors. To remove the seal, cable cutters are required. Once the tamper-evident cable is cut, it can be removed by hand. To open the pail, press on the white handle and turn the lid counter-clockwise. Inside the pail, the material will be contained in a poly bag closed with a twist tie, which can be removed by hand.

      Helpful?

  5. How do you open the 2.5Kg poly drum?

    1 answer
    1. This product is packaged in a 5 L plastic pail with the material inside of a poly bag. There will be a blue twist tie that can be removed by hand. The tamper evident seal is made of steel and can be cut with a pair of cable cutters for a 1/16" diameter wire and then be removed. Once these items have both been removed, the drum can be opened by depressing on the white handle and turning the lid counter-clockwise.

      Helpful?

Reviews

Active Filters

  1. Toronto, ON, CA
    • Review 1
    • Votes 5
    5 out of 5 stars.

    Quality, service and delivery

    The product is good and the service is also good but the delivery is the best, within 24 hours to reach our site.

    Helpful?

  2. 1 Ratings-only review

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico