Saltar al contenido
Merck
  • Inhibition of human efflux transporter ABCC2 (MRP2) by self-emulsifying drug delivery system: influences of concentration and combination of excipients.

Inhibition of human efflux transporter ABCC2 (MRP2) by self-emulsifying drug delivery system: influences of concentration and combination of excipients.

Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques (2015-01-13)
Liang Li, Tao Yi, Christopher Wai-Kei Lam
RESUMEN

This study investigated influences of concentration and combination of excipients, commonly used in self-emulsifying drug delivery systems (SEDDS), on inhibition of human efflux transporter ABCC2 (MRP2). Ten commonly used excipients of SEDDS with inhibitory effect on MRP2 including Cremophor® EL, Cremophor® RH, Pluronic® F127, Maisine® 35-1, β-cyclodextrin, Labrasol®, Pluronic® F68, PEG 2000, PEG 400 and Transcutol® were studied with the Caco-2 cell model. Six excipients with inhibitory effect including Cremophor® EL, Cremophor® RH, Pluronic® F127, PEG 2000, PEG 400 and Transcutol® were further analyzed using the MRP2 vesicle assay and ATPase activity assay. Ultra-performance liquid-chromatography tandem mass spectrometry was used to measure scutellarin as the MRP2 substrate. In studying concentration-dependent effects, five excipients including Cremophor® EL, Cremophor® RH, Pluronic® F127, Maisine® 35-1 and β-cyclodextrin showed concentration-dependent decrease in efflux ratio of scutellarin. The other five excipients did not show such phenomenon, and their inhibitory effects were restricted to be above to certain critical or minimum concentrations. In studying combined effects, PEG 2000 and Pluronic® F127 both showed combined effect with Cremophor® EL on inhibiting MRP2. However, some combinations of excipients such as PEG 400 and Transcutol® with Cremophor® EL increased the scutellarin efflux ratio and decreased the transport of scutellarin and ATPase activity, compared to Cremophor® EL alone. The above results suggest that appropriate choice of excipients according to their concentration-dependent and combined effects on MRP2 inhibition can facilitate formulation of SEDDS for improving the bioavailability of drugs that are MRP2 substrates.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Dimetilsulfóxido, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
Dimetilsulfóxido, ACS reagent, ≥99.9%
Sigma-Aldrich
Dimetilsulfóxido, Molecular Biology
Sigma-Aldrich
Dimetilsulfóxido, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Ácido acético, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Dimetilsulfóxido, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
Ácido acético, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
HEPES, ≥99.5% (titration)
Sigma-Aldrich
Dimetilsulfóxido, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
HEPES, BioPerformance Certified, ≥99.5% (titration)
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Dimetilsulfóxido, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
Ácido acético, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ácido acético solution, suitable for HPLC
Sigma-Aldrich
Dimetilsulfóxido, BioUltra, Molecular Biology, ≥99.5% (GC)
Sigma-Aldrich
HEPES buffer solution, 1 M in H2O
Sigma-Aldrich
Dimetilsulfóxido, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
Piperazine, ReagentPlus®, 99%
Sigma-Aldrich
HEPES, BioUltra, Molecular Biology, ≥99.5% (T)
Sigma-Aldrich
Ácido acético, suitable for luminescence, BioUltra, ≥99.5% (GC)
USP
Ácido acético, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Dimetilsulfóxido, PCR Reagent
Sigma-Aldrich
Acetonitrilo, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrilo, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
HEPES, BioXtra, suitable for mouse embryo cell culture, ≥99.5% (titration)