Passa al contenuto
Merck
  • Use of a glyphosate-based herbicide-induced nephrotoxicity model to investigate a panel of kidney injury biomarkers.

Use of a glyphosate-based herbicide-induced nephrotoxicity model to investigate a panel of kidney injury biomarkers.

Toxicology letters (2013-12-24)
Klintean Wunnapuk, Glenda Gobe, Zoltan Endre, Philip Peake, Jeffrey E Grice, Michael S Roberts, Nicholas A Buckley, Xin Liu
ABSTRACT

Accidental or intentional ingestion of glyphosate surfactant-based herbicides, like Roundup(®), leads to nephrotoxicity as well as death. In this study, a panel of kidney injury biomarkers was evaluated in terms of suitability to detect acute kidney injury and dysfunction. The Roundup(®) intoxication model involved oral administration of glyphosate to rats at dose levels of 250, 500, 1200 and 2500 mg/kg. Urinary and plasma biomarker patterns were investigated at 8, 24 and 48 h after dosing. Biomarkers were quantified by absolute concentration; by normalising to urine creatinine; and by calculating the excretion rate. The diagnostic performances of each method in predicting of acute kidney injury were compared. By Receiver Operating Characteristic (ROC) analysis of the selected biomarkers, only urinary kidney injury molecule-1 (KIM-1) best predicted histological changes at 8h (best cut-off point>0.00029 μg/ml). Plasma creatinine performed better than other biomarkers at 24 h (best cut-off point>0.21 mg/dl). Urinary KIM-1 was the best early biomarker of kidney injury in this glyphosate-induced nephrotoxicity model.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Sigma-Aldrich
Glicina, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
Glicina, suitable for electrophoresis, ≥99%
Sigma-Aldrich
Glicina, BioUltra, Molecular Biology, ≥99.0% (NT)
Sigma-Aldrich
Glicina, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, ≥98.5%
Sigma-Aldrich
Glycine hydrochloride, ≥99% (HPLC)
Supelco
Glyphosate, PESTANAL®, analytical standard
SAFC
Glicina
Supelco
Glicina, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Glicina, BioXtra, ≥99% (titration)
Sigma-Aldrich
Glicina, ACS reagent, ≥98.5%
Sigma-Aldrich
N-(Phosphonomethyl)glycine, 96%
Sigma-Aldrich
Glicina, 99%, FCC
Sigma-Aldrich
Glicina, meets analytical specification of Ph. Eur., BP, USP, 99-101% (based on anhydrous substance)
Sigma-Aldrich
Glicina, puriss. p.a., reag. Ph. Eur., buffer substance, 99.7-101% (calc. to the dried substance)
Sigma-Aldrich
Glycine 1 M solution
Sigma-Aldrich
N-(Phosphonomethyl)glycine, BioReagent, suitable for plant cell culture
Supelco
Glicina, analytical standard, for nitrogen determination according to Kjeldahl method
Supelco
Glycine hydrochloride solution, 100 mM amino acid in 0.1 M HCl, analytical standard
Millipore
MILLIPLEX® Rat Kidney Toxicity Magnetic Bead Panel 1 - Toxicity Multiplex Assay, The analytes available for this multiplex kit are: Clusterin, GSTα, IP-10, KIM-1, OPN - Osteopontin, TIMP-1, VEGF.
Supelco
Glicina, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Glicina, tested according to Ph. Eur.
Millipore
MILLIPLEX® Rat Kidney Toxicity Magnetic Bead Panel 2 - Toxicity Multiplex Assay, The analytes available for this multiplex kit are: Albumin, AGP, β2M, Cystatin C, EGF, Lipocalin-2/NGAL.