コンテンツへスキップ
Merck
  • Simultaneous determination of amino acid and monoamine neurotransmitters in PC12 cells and rats models of Parkinson's disease using a sensitizing derivatization reagent by UHPLC-MS/MS.

Simultaneous determination of amino acid and monoamine neurotransmitters in PC12 cells and rats models of Parkinson's disease using a sensitizing derivatization reagent by UHPLC-MS/MS.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-05-30)
Xian-En Zhao, Shuyun Zhu, Hongmei Yang, Jinmao You, Fengrui Song, Zhiqiang Liu, Shuying Liu
要旨

Multi-analytes simultaneous monitoring of amino acid and monoamine neurotransmitters (NTs) has important scientific significance for their related pathology, physiology and drug screening. In this work, in virtue of a mass spectrometry sensitizing reagent 10-ethyl-acridone-3-sulfonyl chloride (EASC) as derivatization reagent, an Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry (UHPLC-MS/MS) method was developed and validated for simultaneous determination of six amino acid NTs, two monoamine ones and its one metabolite. The simple and rapid derivatization reaction was innovatively combined with plasma preparation by using EASC acetonitrile solution as protein precipitant. This interesting combination brought the advantages of speediness, simpleness and high-throughput in a cost-effective way. Under the optimized conditions, LODs (0.004-3.80nM) and LOQs (0.014-13.3nM) of EASC derivatized-NTs were calculated and found to be significantly lower than those of direct UHPLC-MS/MS detection about 11.5-275.0 and 14.4-371.4 times, respectively. Moreover, EASC derivatization significantly improved chromatographic resolution and matrix effect when compared with direct UPLC-MS/MS detection method without derivatization. Meanwhile, it also brought acceptable precision (3.0-13.0%, peak area CVs%), accuracy (86.4-112.9%), recovery (88.3-107.8%) and stability (3.8-8.5%, peak area CVs%) results. This method was successfully applied for the antiparkinsonian effect evaluation of levodopa and Ginsenoside Rg1 using PC12 cells and rats models by measuring multiple NTs. This provided a new method for the NTs related studies in the future.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
グリシン, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
グリシン, suitable for electrophoresis, ≥99%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
L-アスパラギン酸, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
L-グルタミン酸, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
タウリン, ≥99%
Sigma-Aldrich
グリシン, BioUltra, Molecular Biology, ≥99.0% (NT)
Sigma-Aldrich
グリシン, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, ≥98.5%
Sigma-Aldrich
3,4-ジヒドロキシ-L-フェニルアラニン, ≥98% (TLC)
Sigma-Aldrich
γ-アミノ酪酸, ≥99%
Sigma-Aldrich
L-グルタミン酸, from non-animal source, meets EP testing specifications, suitable for cell culture, 98.5-100.5%
Sigma-Aldrich
L-セリン, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
L-セリン, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
タウリン, suitable for cell culture, meets USP testing specifications
Sigma-Aldrich
酢酸, suitable for luminescence, BioUltra, ≥99.5% (GC)
SAFC
グリシン
Sigma-Aldrich
L-アスパラギン酸, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
アセトニトリル, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
5α-アンドロスタン-17β-オール-3-オン, ≥97.5%
Sigma-Aldrich
アセトニトリル 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
L-グルタミン酸, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
酢酸, ≥99.7%
Sigma-Aldrich
グリシン, BioXtra, ≥99% (titration)
Sigma-Aldrich
グリシン, ACS reagent, ≥98.5%
Sigma-Aldrich
D-セリン, ≥98% (TLC)
Sigma-Aldrich
酢酸, ≥99.5%, FCC, FG
Sigma-Aldrich
ギ酸, ≥95%, FCC, FG
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%