Ammonium Test, photometric

photometric, 0.010-3.00 mg/L (NH4-N), Spectroquant®

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
250 tests

Estimated to ship on16 April 2026fromMerck Life Science N.V.

€188.00
500 tests

Estimated to ship on16 April 2026fromMerck Life Science N.V.

€281.00

About This Item

UNSPSC Code:
41116116
NACRES:
NA.24

€188.00


Estimated to ship on16 April 2026Details


Request a Bulk OrderRequest more information
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Ammonium Test, photometric, 0.010-3.00 mg/L (NH4-N), Spectroquant®

product line

Spectroquant®

Quality Level

usage

sufficient for 250 tests (depending on package size), sufficient for 500 tests

specific analyte(s)

ammonium

measuring range

0.010-3.00 mg/L (NH4-N), 0.013-3.86 mg/L (NH4+)

technique(s)

photometry: suitable

application(s)

agriculture
aquaculture
boiler and cooling water
drinking water
environmental
food testing
ground and surface water
mineral water
oil and petrochemicals
power plants
seawater
swimming pools
wastewater

compatibility

for use with Spectroquant® Move 100, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100 (plus), for use with Spectroquant® Prove 300 (plus), for use with Spectroquant® Prove 600 (plus)

detection method

photometric (Indophenol blue)

storage temp.

15-25°C

General description

Method: Photometric, 0.010 - 3.00 mg/L (NH4-N), Spectroquant®
The method is analogous to EPA 350.1, APHA 4500-NH3 F, ISO 7150-1, and DIN 38406-5.
This Spectroquant® Ammonium Reagent Test allows the cyanide-free quantification of ammonium in wastewater, groundwater, surface water, and seawater. Typically, ammonium enters water sources as run-off from fertilized agricultural areas and enhanced levels are important indicators of fecal pollution.
Further fields of applications are the analysis of foods & beverages and of environmental and agricultural samples (e.g. soil).
The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet.
All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

Legal Information

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
1.006831.111171.14400
detection method

photometric (Indophenol blue)

detection method

photometric (Indophenol blue)

detection method

colorimetric

detection method

colorimetric

specific analyte(s)

ammonium

specific analyte(s)

ammonium

specific analyte(s)

ammonium

specific analyte(s)

ammonium

technique(s)

photometry: suitable

technique(s)

photometry: suitable

technique(s)

-

technique(s)

-

measuring range

0.010-3.00 mg/L (NH4-N), 0.013-3.86 mg/L (NH4+)

measuring range

2.0-150 mg/L (NH4-N), 2.4-193 mg/L (NH3), 2.6-193 mg/L (NH4+)

measuring range

0.5-10 mg/L (NH4+)

measuring range

0.05-0.8  mg/L (NH4+)

compatibility

for use with Spectroquant® Move 100, for use with Spectroquant® Prove 100 (plus), for use with Spectroquant® Prove 600 (plus), for use with Spectroquant® Prove 300 (plus), for use with Spectroquant® Nova 60 A

compatibility

for use with Spectroquant® Move 100, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100 (plus), for use with Spectroquant® Prove 300 (plus), for use with Spectroquant® Prove 600 (plus)

compatibility

for use with MQUANT®

compatibility

for use with MQuant®

application(s)

agriculture
aquaculture
boiler and cooling water
drinking water
environmental
food testing
ground and surface water
mineral water
oil and petrochemicals
power plants
seawater
swimming pools
wastewater

application(s)

agriculture
biotechnology/fermenter
disposal drainage water
drinking water
food testing
ground and surface water
seawater
wastewater

application(s)

-

application(s)

-


Still not finding the right product?

Explore all of our products under Ammonium Test


signalword

Danger

Hazard Classifications

Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Dam. 1 - Flam. Liq. 2 - Met. Corr. 1 - Skin Corr. 1B - STOT SE 3

target_organs

Central nervous system

Storage Class

3 - Flammable liquids

wgk

WGK 3



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Protocols

Step-by-step method describing the photometric determination of ammonium ions in effluents using Spectroquant® test kits and spectrophotometer.

Photometric determination of ammonium ions in drinking and surface water samples by indophenol blue method using Spectroquant® test kits and spectrophotometer.

Photometric determination of ammonium ions in organic fertilizers by indophenol blue method using Spectroquant® test kits and spectrophotometer.

View All Protocols

Articles

Complete wastewater testing solutions for every treatment stage with instruments, test kits, and standards to ensure compliant, reliable water analysis.


Teresa Steliga et al.
Molecules (Basel, Switzerland), 25(3) (2020-02-12)
Biodegradation is one of the most effective and profitable methods for the elimination of toxic polychlorinated biphenyls (PCBs) and total petroleum hydrocarbons (TPH) from the environment. In this study, aerobic degradation of the mentioned pollutants by bacterial strains Mycolicibacteriumfrederiksbergense IN53



Global Trade Item Number

SKUGTIN
114752000204027269074296
114752000104022536156514

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters