Wybierz wielkość
| Rozmiar/SKU | Dostępność | Cena netto |
|---|---|---|
5 x 5 mL | Dostępne do wysyłki DZISIAJzKuehne + Nagel Sp. z o.o. | 12 750,00 zł |
5 x 20 mL | Przewidywany termin wysyłki16 października 2026zKuehne + Nagel Sp. z o.o. | 13 950,00 zł |
Informacje o tej pozycji
12 750,00 zł
Dostępne do wysyłki DZISIAJSzczegóły
Quality Segment
material
C-Flex tubing, polycarbonate Luer lock, polycarbonate body, polycarbonate container, silicone tubing
sterility
sterile; β-irradiated
product line
NovaSeptum® SURe
storage condition
room temperature
parameter
-80-50 °C temp. range (-112-122 °F), 0.50 bar max. pressure (7.25 psi)
volume
5 mL (20 mL)
fitting
Luer-Lok® inlet connection (3-piece), inlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site)
application(s)
sterile sampling
General description
This product comes as a manifolded unit with accurate volume syringes and connects via C-flex® tubing for thermowelding. The syringes enable sampling for small, accurate volumes, which is particularly important for sampling of high value products. The closed design ensures your sample will be isolated from point of sample to analysis, reducing the risk of losing valuable product and maintaining the integrity of your fluid samples.
Application
Features and Benefits
- Product design ensures process integrity and a representative sample from single-use manufacturing processes
- Industry-standard aseptic connection and disconnection for easy integration into your single-use process
- Other container options available: bags, bottles, syringes, and conical tubes
- Stocked and ready-to-ship for fast delivery
Packaging
Preparation Note
Analysis Note
Other Notes
Legal Information
1 of 1
Ta pozycja | |||
|---|---|---|---|
| description Manifold (5-valve) with Inlet C-Flex® Tubing, sterile; β-irradiated, volume 5 mL (20 mL) | description Manifold (5-valve) with AseptiQuik® S connector, sterile; γ-irradiated, volume 5 mL (20 mL) | description Manifold (5-valve) with AseptiQuik® S connector, sterile; γ-irradiated, volume 15 mL | description Manifold (5-valve) with Inlet C-Flex® Tubing, sterile; β-irradiated, volume 100 mL |
| fitting inlet connection (containing a male, female and an injection site), Luer-Lok® inlet connection (3-piece), outlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3-piece) | fitting outlet connection (containing a male, female and an injection site), inlet connection (Silicone), Luer-Lok® outlet connection (3-piece) | fitting Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site), inlet connection (TPE) | fitting Luer-Lok® inlet connection (3-piece), outlet connection (containing a male, female and an injection site), inlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3-piece) |
| product line NovaSeptum® SURe | product line NovaSeptum® SURe | product line NovaSeptum® SURe | product line NovaSeptum® SURe |
| material silicone tubing, polycarbonate Luer lock, polycarbonate container, C-Flex tubing, polycarbonate body | material polycarbonate connector, polycarbonate container, silicone tubing, polypropylene body | material polystyrene body, TPE tubing, polycarbonate connector, polystyrene container | material polyethylene body, polycarbonate Luer lock, polyethylene container, C-Flex tubing, TPE tubing |
| sterility sterile; β-irradiated | sterility sterile; γ-irradiated | sterility sterile; γ-irradiated | sterility sterile; β-irradiated |
| parameter 0.50 bar max. pressure (7.25 psi), -80-50 °C temp. range (-112-122 °F) | parameter 4-40 °C temp. range (39-104 °F), 0.50 bar max. pressure (7.25 psi) | parameter 0.30 bar max. pressure (4.35 psi), 4-40 °C temp. range (39-104 °F) | parameter 0.30 bar max. pressure (4.35 psi), -80-50 °C temp. range (-112-122 °F) (when used with a NovaSeptum® Case) |
| storage condition room temperature | storage condition room temperature | storage condition room temperature | storage condition room temperature |
Still not finding the right product?
Explore all of our products under NovaSeptum® SURe Accurate Volume Syringe Sampling Unit
Zgodność z GMP dzięki programowi Emprove®
Przyspiesz kwalifikacje, zachowaj zgodność i oszczędzaj czas dzięki Emprove® Dossiers.
Uwaga: zostaniesz przeniesiony do EmproveSuite.com. Twoja nazwa użytkownika i hasło są niezależne od SigmaAldrich.com i mogą się różnić.
Zarejestruj się za darmo i uzyskaj dostęp do Emprove® Dossiers w ciągu kilku minut. Uaktualnij swój plan subskrypcji, aby odblokować zaawansowaną i spersonalizowaną zawartość w Emprove® Suite.
Nie znalazłeś tego, czego szukasz? Odwiedź stronę pomocy programu Emprove®..
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Masz trudności ze znalezieniem produktu lub numeru serii/partii?
Jak znaleźć numer produktu
Podczas wyświetlania na stronie internetowej numery produktów są łączone z wielkością przesyłki / ilością (przykład: T1503-25G). Pamiętaj że w polu „Numer produktu” należy podać TYLKO numer produktu (przykład: T1503).
Przykład:
Przykłady dodatkowe:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
wpisz jako 1.000309185)
Mieć kłopoty? Poczuj się swobodnie w kontakcie Pomoc techniczna dla wsparcia