Przejdź do zawartości
Merck

Prediction of skeletal muscle and fat mass in patients with advanced cancer using a metabolomic approach.

The Journal of nutrition (2011-12-14)
Cynthia Stretch, Thomas Eastman, Rupasri Mandal, Roman Eisner, David S Wishart, Marina Mourtzakis, Carla M M Prado, Sambasivarao Damaraju, Ronald O Ball, Russell Greiner, Vickie E Baracos
ABSTRAKT

Urine and plasma metabolites originate from endogenous metabolic pathways in different organs and exogenous sources (diet). Urine and plasma were obtained from advanced cancer patients and investigated to determine if variations in lean and fat mass, dietary intake, and energy metabolism relate to variation in metabolite profiles. Patients (n = 55) recorded their diets for 3 d and after an overnight fast they were evaluated by DXA and indirect calorimetry. Metabolites were measured by NMR and direct injection MS. Three algorithms were used [partial least squares discriminant-analysis, support vector machines (SVM), and least absolute shrinkage and selection operator] to relate patients' plasma/urine metabolic profile with their dietary/physiological assessments. Leave-one-out cross-validation and permutation testing were conducted to determine statistical validity. None of the algorithms, using 63 urine metabolites, could learn to predict variations in individual's resting energy expenditure, respiratory quotient, or their intake of total energy, fat, sugar, or carbohydrate. Urine metabolites predicted appendicular lean tissue (skeletal muscle) with excellent cross-validation accuracy (98% using SVM). Total lean tissue correlated highly with appendicular muscle (Pearson r = 0.98; P < 0.0001) and gave similar cross-validation accuracies. Fat mass was effectively predicted using the 63 urine metabolites or the 143 plasma metabolites, exclusively. In conclusion, in this population, lean and fat mass variation could be effectively predicted using urinary metabolites, suggesting a potential role for metabolomics in body composition research. Furthermore, variation in lean and fat mass potentially confounds metabolomic studies attempting to characterize diet or disease conditions. Future studies should account or correct for such variation.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Acetone, ≥99%, FCC, FG
Sigma-Aldrich
Hippuric acid, 98%
Sigma-Aldrich
Acetone, natural, ≥97%
Sigma-Aldrich
L-Alanine, ≥99%
Supelco
L-Alanine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Propylene glycol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Mannitol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Glycine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
D-Mannitol, ≥99.9999% (metals basis), for boron determination
Supelco
L-Valine, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
D-Mannitol, tested according to Ph. Eur.
Sigma-Aldrich
L-Alanine, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
Glycine, meets analytical specification of Ph. Eur., BP, USP, 99-101% (based on anhydrous substance)
Sigma-Aldrich
Acetic acid, suitable for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
4-Hydroxyphenylacetic acid, 98%
Sigma-Aldrich
Glycine, BioUltra, Molecular Biology, ≥99.0% (NT)
Supelco
Acetone, analytical standard
Sigma-Aldrich
Glycine, tested according to Ph. Eur.
Sigma-Aldrich
D-Mannitol, BioUltra, ≥99.0% (sum of enantiomers, HPLC)
Sigma-Aldrich
Glycine, puriss. p.a., reag. Ph. Eur., buffer substance, 99.7-101% (calc. to the dried substance)
Millipore
D-Mannitol, ACS reagent, suitable for microbiology, ≥99.0%
Sigma-Aldrich
L-Valine, BioUltra, ≥99.5% (NT)
SAFC
L-Valine
SAFC
Glycine
Sigma-Aldrich
Glycolic acid solution, technical grade, 70 wt. % in H2O
Sigma-Aldrich
Glycolic acid, ReagentPlus®, 99%
Sigma-Aldrich
Glycine, 99%, FCC
Sigma-Aldrich
Propylene glycol, ≥99.5% (GC), FCC, FG