Przejdź do zawartości
Merck

Stir fabric phase sorptive extraction for the determination of triazine herbicides in environmental waters by liquid chromatography.

Journal of chromatography. A (2014-12-24)
Mercedes Roldán-Pijuán, Rafael Lucena, Soledad Cárdenas, Miguel Valcárcel, Abuzar Kabir, Kenneth G Furton
ABSTRAKT

Stir fabric phase sorptive extraction (SFPSE), which integrates sol-gel hybrid organic-inorganic coated fabric phase sorptive extraction media with a magnetic stirring mechanism, is presented for the first time. Two flexible fabric substrates, cellulose and polyester were used as the host matrix for three different sorbents e.g., sol-gel poly(tetrahydrofuran), sol-gel poly(ethylene glycol), and sol-gel poly(dimethyldiphenylsiloxane). The new microextraction device has been analytically evaluated using triazine herbicides as model compounds. The factors affecting the extraction efficiency of SFPSE have been investigated and the optimal extraction conditions have been determined. Under these optimum conditions, the limits of quantification (LOQs) for sol-gel poly(ethylene glycol) coated SFPSE device in combination with UPLC-DAD for the analysis of the seven triazine herbicides were in the range of 0. 26-1.50μg/L with precision (relative standard deviation) at 2μg/L concentration ranging from 1.4-4.8% (intra-day, n=5) and 6.8-11.8% (inter-day, n=3). Enrichment factors were found between 444 and 1411 (compared to 2000 theoretical maximum). Absolute extraction recoveries were in the range of 22.2-70.5%. The developed method was applied for the determination of selected triazine herbicides from three river water samples. Relative recoveries of the target analytes, in the range from 75 to 126%, were found to be satisfactory. The combination of SFPSE with LC-MS/MS allows the improvement of the method sensitivity to the range from 0.015μg/L to 0.026μg/L with precision better than 10.8% expressed as relative standard deviation (RSD).

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Supelco
Dichloromethane, Selectophore, ≥99.5%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
Trifluoroacetic acid, analytical standard
Sigma-Aldrich
2-Methyl-2-propanethiol, 99%
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Methylene Chloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
Atrazine, analytical standard
Supelco
Atrazine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
Atrazine, PESTANAL®, analytical standard
Supelco
Dichloromethane, analytical standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Trifluoroacetic acid, suitable for HPLC, ≥99.0%
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Dichloromethane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Trifluoroacetic acid, ReagentPlus®, 99%
Sigma-Aldrich
Trifluoroacetic acid, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Trifluoroacetic acid, ≥99%, for protein sequencing
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Dichloromethane, biotech. grade, 99.9%, contains 40-150 ppm amylene as stabilizer