S2GPU10RE

Millipore® Stericup®Quick Release真空过滤系统

pore size 0.22 μm, polyethersulfone membrane, filter capacity 500 mL, pack of 12 ea

别名:

SCGPU10RE


登录 查看公司和协议定价

选择尺寸

12 EA

$489.00

$489.00


预计发货时间2025年12月26日详情


索取更多信息

关于此项目

分類程式碼代碼:
41104914
eCl@ss:
32031623
NACRES:
NB.24

跳至

技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

材料

polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing

品質等級

無菌

sterile; irradiated

產品線

Stericup®

特點

hydrophilic

包裝

pack of 12 ea

參數

45 °C max. temp.

描述

2.4 mL (hold-up volume)

技術

sterile filtration: suitable

高度

299 mm

直徑

12.5 cm

過濾器容量

500 mL

過濾器直徑

73 mm

過濾面積

40 cm2

基質

Express PLUS

孔徑

0.22 μm pore size

接頭

inlet funnel
outlet flask (Receiver)

運輸包裝

ambient

相关类别

比较类似商品

查看完整比较结果

显示差异

1 of 4

此商品
S2GPU11RES2GPU01RES2GPU02RE
pore size

0.22 μm pore size

pore size

0.22 μm pore size

pore size

0.22 μm pore size

pore size

0.22 μm pore size

material

polyethersulfone membrane, polystyrene funnel(s), polystyrene bottle, polystyrene housing

material

polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing

material

polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing

material

polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing

sterility

sterile; irradiated

sterility

sterile; irradiated

sterility

sterile; irradiated

sterility

sterile; irradiated

packaging

pack of 12 ea

packaging

pack of 12 ea

packaging

pack of 12 ea

packaging

pack of 12 ea

fitting

inlet funnel, outlet flask (Receiver)

fitting

inlet funnel, outlet flask (Receiver)

fitting

inlet funnel, outlet flask (Receiver)

fitting

inlet funnel, outlet flask (Receiver)

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

一般說明

该产品直接替代SCGPU10RE
采用Stericup®和Steritop®过滤系统可以轻松自信地完成过滤工作。

Stericup®和Steritop ®无菌过滤器设备采用可靠的高性能膜,可实现实验室试剂、缓冲液和培养基的最佳无菌过滤操作。 这些设备将良好的流速和处理量与低非特异性结合和稳定的无尖端设计结合起来

这种Stericup® 0.22 μm 孔径聚偏氟乙烯(PVDF)膜过滤器装置结合了500 mL瓶顶过滤器和1000 mL 接收瓶及瓶盖,便于加工和储存。

應用

Stericup®和 Steritop®系统是为了减少起泡和蛋白质变性同时最大程度提高流速而设计,可用于水溶液 (如组织培养基和生物体液)的无菌真空过滤。

  • 组织培养基 +/- 添加剂
  • 缓冲液
  • 生物溶液
仅供研究使用

特點和優勢

  • 该 Quick Release过滤器漏斗旋转四分之一圈即可从接收瓶上拆下 —减少溢出的可能性,并且 在实验台或通风橱中更容易操作。
  • Steritop ®过滤器漏斗上的Bold产品标识清楚地 显示了膜特性,包括组成和孔径, 可用于快速选择适合应用的产品。
  • 密封盖为法兰连接并经过改良以便在潮湿和干燥条件下 均能握紧—可触摸塞确保牢固的密封。不用担心 灭菌的内容物可能受污染或溢出
  • 接收瓶上充足的磨砂书写表面和更浅的瓶盖颜色 便于清楚标识,以改善易读性并减少不可读的 污迹。
  • 密封盖位于侧面以防污染风险。
  • 接收瓶可堆叠以节省储存空间。

法律資訊

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

商品

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Select the right sterile filter by media, volume, and application.

相关内容

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

Questions

1–10 of 15 Questions  
  1. What Bacterial Endotoxins Test is used?

    1 answer
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Helpful?

  2. Can Stericup® and Steritop® filters be reused?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single use, disposable processing.

      Helpful?

  3. What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
      *Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.

      Helpful?

  4. The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?

    1 answer
    1. Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
      Glass bottles, GL33:
      • Wheaton media bottles (glass), 500 mL (Product Z364886)
      • Wheaton media bottles (glass), 1 L (Product Z364894)
      Glass bottles, GL45
      • Corning® glass media storage bottle, 125 mL (Product CLS1399125)
      • Corning® glass media storage bottle, 250 mL (Product CLS1399250)
      • Corning® glass media storage bottle, 500 mL (Product CLS1399500)
      • Corning® glass media storage bottle, 1 L (Product CLS13991L)
      • Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
      • Pyrex® round media storage bottle, 1 L (Product CLS13951L)
      • KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
      • KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
      • KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
      Plastic (pre-sterile) bottles, GL45:
      • Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
      • Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
      • Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)

      Helpful?

  5. Can Stericup® bottles be placed inside freezers for long-term storage of media?

    1 answer
    1. You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.

      Helpful?

  6. What is the expiration date of Stericup® and Steritop® filters?

    1 answer
    1. Typically 3 years from sterilization.

      Helpful?

  7. What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?

    1 answer
    1. Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.

      Helpful?

  8. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  9. What tubing can be used with Stericup® and Steritop® vacuum filters?

    What tubing can be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004

      Helpful?

  10. Are Stericup® and Steritop® filters GMP-certified?

    1 answer
    1. No, Stericup® and Steritop® devices are not GMP-approved.

      Helpful?

1–10 of 15 Questions  