We have not studied stacking Swinnex filters in series one after the other for double and separate filtration. One could attempt this but may need a stronger vacuum source to pull samples through both or a stronger pushing source such as a syringe. Depending on the sample matrix with particle type and concentration, one could also try stacking two filters on top of each other in one device. Both options have not been attempted and there is a higher element of risk of this functioning on many initial studies.
材料
polypropylene device
silicone gasket
silicone seal
品質等級
agency
suitable for EPA 200.7
suitable for EPA 200.8
suitable for EPA 300
製造商/商標名
Swinnex®
參數
5.2 bar max. inlet pressure (75 psi)
技術
pressure filtration: suitable
長度
5.4 cm
直徑
5.8 cm (2.3 in.)
過濾器直徑
47 mm
過濾面積
13.8 cm2
預濾器直徑
42 mm , thick depth prefilter
47 mm , membrane prefilter
接頭
1/4 in. NPT inlet connection thread(s)
1/4 in. male NPT inlet fitting (with female Luer slip interior)
female Luer outlet slip
應用
filtration
相容性
for use with Sterifil Aseptic System
運輸包裝
ambient
一般說明
特点 & 优势:
•提供三种尺寸,适用于各种处理量
•可在高压灭菌器中放置过滤器以进行无菌过滤
SX0001300 Swinnex 换膜过滤器,13 mm
SX0002500 Swinnex 换膜过滤器,25 mm
SX0004700 Swinnex 换膜过滤器,47 mm
更换零件
SX0001301 13 mm Swinnex 换膜过滤器的硅胶垫圈
SX0002501 25 mm Swinnex 换膜过滤器的硅胶垫圈
XX2702510 支撑网,25 mm,聚丙烯
XX1104715 支撑网,47 mm,聚丙烯
XX1104707 硅胶 O-型圈 (5-329), Swinnex 47 mm 换膜过滤器用
SX0004701 Swinnex 47 mm 换膜过滤器的底座 O 型圈,硅胶
SX00047RK Swinnex 47 mm 换膜过滤器的替换组件
生化/生理作用
準備報告
可装有过滤器进行高压灭菌
法律資訊
实验方案
This is a User Guide Dispensing Pressure Vessel Fitting Kit from Millipore.
相关内容
This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.
-
Can you stack these filter holders so liquid passes from a syringe, through the first filter holder, then a second filter holder and then out the other end?
1 answer-
Helpful?
-
-
What type of syringe is compatible with the SX0004700? Is an adapter required for this syringe?
1 answer-
It is recommended to use luer slip syringe (not luer lok) for the Swinnex 47 SX0004700, as it fits inside the inlet. No additional adapter is required. Additionally, the Swinnex 47 has a ¼ NPTM inlet, which includes the female luer slip interior.
Here are examples of syringes that are compatible with the Swinnex 47 and their sample holding capacities:
Z683590-100EA: Polypropylene LUER SLIP syringe, 10 ml, pack of 100
XX1102012: 20mL Luer slip polypropylene syringe, pack of 12
XX1105005: 50mL Luer slip polypropylene syringe, pack of 5Helpful?
-
-
Is it necessary to use two different O-rings for the Swinnex 47 (SX0004700)?
1 answer-
Yes, two different o-rings are required for the Swinnex 47 mm filter holder (SX0004700). One is for the inlet, which is a cone-shaped component, and the other is for the base, which has a flat surface to hold the filter.
The XX1104707 o-ring seals the filter membrane in place and fits in the groove on the top (inlet) part, while the SX0004701 is the base o-ring and goes on the base (outlet).
Helpful?
-
-
Good day, I see in packaging it states 8pkg - just to be sure, does that mean that the prize is for a package of 8 holders?
1 answer-
Yes, this is a package of 8 Swinnex 47mm Filter Holders.
Helpful?
-