Direkt zum Inhalt
Merck

50814-U

Ascentis® Express 90 Å C18 (2 μm) HPLC Columns

L × I.D. 15 cm × 2.1 mm UHPLC Column

Synonym(e):

Core-shell (SPP) Fused Core C18 HPLC column

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Größe auswählen

Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Über diesen Artikel

UNSPSC-Code:
41115700
NACRES:
SB.52

Fortfahren mit

Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten

Produktname

Ascentis® Express C18, 2 μm UHPLC Column, 2 μm particle size, L × I.D. 15 cm × 2.1 mm

Materialien

stainless steel column

Qualitätsniveau

Agentur

suitable for USP L1

Produktlinie

Ascentis®

Leistungsmerkmale

endcapped

Hersteller/Markenname

Ascentis®

Verpackung

1 ea of

Parameter

1000 bar max. pressure (14500 psi)
60 °C temp. range

Methode(n)

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

L × ID

15 cm × 2.1 mm

Oberflächenbereich

120 m2/g

Verunreinigungen

<5 ppm metals

Matrix

Fused-Core particle platform
superficially porous particle

Aktive Matrixgruppe

C18 (octadecyl) phase

Partikelgröße

2 μm

Porengröße

90 Å pore size

Betriebs-pH-Wert

2-9

Anwendung(en)

food and beverages

Trenntechnik

reversed phase

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Ähnliche Artikel vergleichen

Vollständigen Vergleich anzeigen

Unterschiede anzeigen

1 of 4

Dieser Artikel
50821-U50819-U50809-U
L × I.D.

15 cm × 2.1 mm

L × I.D.

15 cm × 3 mm

L × I.D.

10 cm × 3 mm

L × I.D.

3 cm × 2.1 mm

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

particle size

2 μm

particle size

2 μm

particle size

2 μm

particle size

2 μm

matrix active group

C18 (octadecyl) phase

matrix active group

C18 (octadecyl) phase

matrix active group

C18 (octadecyl) phase

matrix active group

C18 (octadecyl) phase

agency

suitable for USP L1

agency

suitable for USP L1

agency

suitable for USP L1

agency

suitable for USP L1

technique(s)

HPLC: suitable, UHPLC-MS: suitable, LC/MS: suitable, UHPLC: suitable

technique(s)

LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable

technique(s)

LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable

technique(s)

LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable

Sonstige Hinweise

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Rechtliche Hinweise

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Silvia Jakabová et al.
Journal of chromatography. A, 1232, 295-301 (2012-03-07)
Hyoscyamine (atropine) and scopolamine are the predominant tropane alkaloids in the Datura genus, occurring in all plant organs. The assessment of the alkaloid content of various plant parts is essential from the viewpoint of medical use, but also as a
Heena et al.
Journal of chromatographic science, 53(5), 800-806 (2014-10-18)
This study represents a new analytical high-performance liquid chromatography-fluorescence detector method for the determination of Al(III) as Al(III) complex with 8-hydroxyquinoline-5-sulfonic acid in a tap water sample and a coke sample. A micellar liquid chromatographic method is proposed for the
Judy Stone
Methods in molecular biology (Clifton, N.J.), 1378, 301-320 (2015-11-26)
Serum from bar-coded tubes, and then internal standard, are pipetted to 96-well plates with an 8-channel automated liquid handler (ALH). The first precipitation reagent (methanol:ZnSO4) is added and mixed with the 8-channel ALH. A second protein precipitating agent, 1 %
Petra Šilarová et al.
Food chemistry, 237, 471-480 (2017-08-03)
The degradation of catechins and other phenolics in green tea infusions were monitored using fast HPLC/MS separation. The final separation was performed within 2.5min using Ascentis Express C18 column (50mm×2.1mm i.d.) packed with 2μm porous shell particles. Degradation was studied
Babu Rao Chandu et al.
SpringerPlus, 2(1), 194-194 (2013-06-07)
A bioequivalence study was proved of generic Febuxostat 80 mg tablets (T) in healthy volunteers.For this purpose, Authors developed a simple, sensitive, selective, rapid, rugged and reproducible liquid chromatography-tandem mass spectrometry method for the quantification of Febuxostat (FB) in human

Artikel

Ein vollständiger Arbeitsablauf für die HPLC-Trennung von 17 Cannabinoiden in verschiedenen Cannabisprodukten unter Verwendung der Ascentis® Express C18-Säule in einer kürzeren Laufzeit mit stabiler Retentionszeit. Hier erfahren Sie mehr.

A complete workflow for the HPLC separation of 17 cannabinoids in different cannabis products using Ascentis® Express C18 Column in a shorter run time with retention time stability. Learn more here.

Overview of gradient HPLC-based cannabinoid analysis optimized for key method parameters.

Protokolle

HPLC separation of 17 important cannabinoids including CBD, delta 9 THC and THCA. Read the application note.

Verwandter Inhalt

Ascentis® Express 2.0 μm C18 Column Care & Use Sheet

Questions

  1. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung