Technically, there is no limit to the percentage of water that can be used on a bare silica column. However, exposing the column to 100% water would require several hours to re-equilibrate back to typical HILIC conditions. Nevertheless, it is advisable to use 95% water and 5% Acetonitrile to avoid dewetting the phase, unless the column is explicitly labeled as aqueous compatible. After flushing the column sufficiently, a re-equilibration of no fewer than 75 column volumes is recommended.
Größe auswählen
Über diesen Artikel
Fortfahren mit
Produktname
Ascentis® Si HPLC-Säule, 3 μm particle size, L × I.D. 15 cm × 2.1 mm
material
stainless steel column
agency
suitable for USP L3
product line
Ascentis®
feature
endcapped: no
manufacturer/tradename
Ascentis®
packaging
1 ea of
parameter
≤70 °C temp. range
400 bar pressure (5801 psi)
technique(s)
HPLC: suitable
LC/MS: suitable
L × I.D.
15 cm × 2.1 mm
surface area
450 m2/g
impurities
<5 ppm metals
matrix
fully porous particle
silica gel high purity, spherical
matrix active group
silica phase
particle size
3 μm
pore size
100 Å
operating pH range
2-6
application(s)
food and beverages
separation technique
hydrophilic interaction (HILIC)
normal phase
Quality Level
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Verwandte Kategorien
1 of 4
Dieser Artikel | 581514-U | 581513-U | 581503-U |
|---|---|---|---|
| particle size 3 μm | particle size 5 μm | particle size 5 μm | particle size 3 μm |
| matrix active group silica phase | matrix active group silica phase | matrix active group silica phase | matrix active group silica phase |
| L × I.D. 15 cm × 2.1 mm | L × I.D. 25 cm × 10 mm | L × I.D. 25 cm × 4.6 mm | L × I.D. 10 cm × 3 mm |
| separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase |
| agency suitable for USP L3 | agency suitable for USP L3 | agency suitable for USP L3 | agency suitable for USP L3 |
| product line Ascentis® | product line Ascentis® | product line Ascentis® | product line Ascentis® |
General description
Legal Information
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
-
What is the maximum percentage of water that should not be exceeded when using this column to prevent deactivation of the silica?
1 answer-
Helpful?
-
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung