Passa al contenuto
Merck

KVEPS015FB3

Millipore Express® SHR 0.1µm, Opticap® XL 150 Capsule

Fittings 3/4 in. TC- 9/16 in. HB with Bell, Sterile

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

Prezzi e disponibilità al momento non sono disponibili

Informazioni su questo articolo

Codice UNSPSC:
23151806

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Nome del prodotto

Millipore Express® SHR, Opticap® XL Capsule, sterile, Opticap® XL 150, cartridge nominal length 3.8 in. (9.7 cm), filter diam. 5.6 cm (2.2 in.)

Materiali

polyethylene support
polypropylene device
polypropylene housing
polypropylene vent cap
silicone seal

Livello qualitativo

Conformità normativa

meets FDA 21 CFR 177-182 (all component materials)

Sterilità

irradiated
sterile

Nome Commerciale

Opticap® XL 150

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Millipore Express®

Parametri

≤1.4 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

tecniche

sterile filtration: suitable

Lunghezza nominale della cartuccia

3.8 in. (9.7 cm)

Lungh. del dispositivo

9.7 cm (3.8 in.)

Diam. filtro

5.6 cm (2.2 in.)

Superficie filtrante del filtro

250 cm2

Impurezze

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)

Matrice

Millipore Express® SHR

Dimensione pori

0.1 μm pore size

Punto di bolla

≥4000 mbar (58 psig), air with water

Raccordi

(19 mm (¾ in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet with filling bell)

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Device Configuration: Capsule

Confezionamento

Double Easy-Open bag

Nota sulla preparazione

Sterilization Method:
3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Risultati analitici

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
TOC/Conductivity: After sterilization and a controlled water flush of 2.0 L, samples exhibited &#x3C 500 ppb TOC per USP &#x3C 643 &#x3C and &#x3C 1.3 μS/cm per USP &#x3C 645 &#x3C at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 1 L

Altre note

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Note legali

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Mantenere la conformità alle GMP utilizzando il programma Emprove®.

Accelerate la qualificazione, mantenete la conformità e risparmiate tempo con Emprove® Dossiers.

Scarica Dossiers

Nota: verrete portati su EmproveSuite.com. Il vostro nome utente e la vostra password sono separati da SigmaAldrich.com e possono essere diversi.

Registrati gratuitamente e accedi a Emprove® Dossiers in pochi minuti. Aggiornate il vostro piano di abbonamento per sbloccare contenuti avanzati e personalizzati nella Emprove® Suite.

Non trovate quello che state cercando? Visitate la pagina di aiuto del programma Emprove®..

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Questions

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica