Passa al contenuto
Merck

MSIPS4W10

Piastra Multiscreen® a 96 pozzetti, membrana in PVDF idrofoba

pore size 0.45 μm, sterile

Multiscreen® 96 well Plate, hydrophobic PVDF membrane

Sinonimo/i:

Piastra a 96 pozzetti idrofoba, Piastra a 96 pozzetti in PVDF

Autenticati per visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

Prezzi e disponibilità al momento non sono disponibili

Informazioni su questo articolo

Codice UNSPSC:
41104923
eCl@ss:
32039006
NACRES:
NB.22

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Materiali

Durapore PVDF membrane
flat bottom wells
white acrylic plate

Livello qualitativo

Descrizione

Sterile, white 96-well filter plate with 0.45 um pore size Hydrophobic PVDF membrane for ELISPOT Assays. Comes in a pack of 10.

Sterilità

sterile

impiego

Automated

Caratteristiche

hydrophobic
lid

Confezionamento

pkg of 10 plates

Produttore/marchio commerciale

MultiScreen®

tecniche

ELISPOT: suitable
cell based assay: suitable
dot blot: suitable

Superficie filtrante

0.28 cm2

Dimens. piastra

96 wells

Volume massimo del pozzetto

300 μL

Volume d’esercizio

50-250 μL

Matrice

Immobilon®-P

Dimensione pori

0.45 μm pore size

Tipo di binding

high binding surface

Compatibilità

centrifuge & manifold

Condizioni di spedizione

ambient

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
MSHVN4BMAIPN4550MSIPN4B10
binding type

high binding surface

binding type

low binding surface

binding type

high binding surface

binding type

high binding surface

material

PVDF membrane (hydrophobic), flat bottom wells, acrylic

material

Barex® , PVDF membrane (hydrophilic), flat bottom wells, titanium dioxide

material

PVDF membrane (hydrophobic), acrylic , flat bottom wells

material

Barex® , PVDF membrane (hydrophobic), flat bottom wells, titanium dioxide

sterility

sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

working volume

50-250 μL

working volume

50-250 μL

working volume

50-250 μL

working volume

50-250 μL

Descrizione generale

The polyvinylidene fluoride (PVDF) membrane plates are recommended, over a mixed cellulose ester format, due to slightly improved binding of capture antibody and superior performance in spot detection, particularly for fluorescent applications.

Applicazioni

®μ

Note legali

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany
MULTISCREEN is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Katrin Klocke et al.
Immunology, 152(1), 125-137 (2017-05-13)
Cytotoxic T-lymphocyte antigen 4 (CTLA-4) -mediated regulation of already tolerized autoreactive T cells is critical for understanding autoimmune responses. Although defects in CTLA-4 contribute to abnormal FOXP3+ regulatory T (Treg) cell function in rheumatoid arthritis, its role in autoreactive T
Mubeen M Mosaheb et al.
Nature communications, 11(1), 524-524 (2020-01-29)
Viruses naturally engage innate immunity, induce antigen presentation, and mediate CD8 T cell priming against foreign antigens. Polioviruses can provide a context optimal for generating antigen-specific CD8 T cells, as they have natural tropism for dendritic cells, preeminent inducers of
Jing Zhu et al.
Journal of immunology (Baltimore, Md. : 1950), 204(5), 1091-1100 (2020-01-29)
Almost a decade has passed since the approval of belimumab, an mAb directed against B lymphocyte stimulation and the first targeted therapy approved for systemic lupus erythematous (SLE) in over 50 y. Although well tolerated, the efficacy of belimumab remains
Leah E Cole et al.
Vaccines, 8(4) (2020-12-06)
While both whole-cell (wP) and acellular pertussis (aP) vaccines have been highly effective at reducing the global pertussis disease burden, there are concerns that compared to wP vaccination, the immune responses to aP vaccination may wane more rapidly. To gain

Articoli

ELISpot assay provides qualitative and quantitative information on immune responses, visualizing multiple secretory products from single responding cells.

Protocolli

Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.

The ELISpot (Enzyme Linked Immuno-Spot) assay provides an effective method of measuring the antibody or cytokine production of immune cells on the single cell level.

Contenuto correlato

This provides information about the chemical compatibility of MultiScreen Filter Plates with different reagents.

The ELISpot (Enzyme Linked Immuno-Spot) assay provides an effective method of measuring the antibody or cytokine production of immune cells on the single cell level. The popularity of this assay has seen resurgence in recent years as researchers attempt to gain a better understanding of immune responses in a variety of applications. The following protocol is an example of a typical ELISpot assay for quantifying the number cells producing interferon-gamma (IFN-γ) in response to antigen or non-specific activation using phytohemagglutinin (PHA). It may be optimized as necessary for other applications.

"Under optimal conditions, the enzyme-linked immunosorbent spot (Elispot) assay enables visualization of multiple secretory products from a single responding cell. Thus, the Elispot provides both qualitative (type of immune protein) and quantitative (number of responding cells) information. By virtue of this assay’s unsurpassed sensitivity, frequency analysis of rare cell populations (e.g., antigen-specific responses) which were not possible before are now relatively easy. Recent improvements to the design of multiwell microplates, including use of membranes with reduced background fluorescence, have bolstered the widespread application of Elispot assays. When assay sensitivity, ease of use, and cost are all taken into consideration, the Elispot platform is likely the superior choice for the development of multifunctional T cell assays for the research, therapeutic, and diagnostic communities."

MultiScreen® Filter Plates

Vedi tutto

Questions

  1. Do MSIPS4W10 and S5EM077I10 refer to the same plate?

    1 answer
    1. Yes, both MSIPS4W10 and S5EM077I10 correspond to the same plate, identified by the description: MultiScreen HTS IP PVDF 0.45um White Sterile 10pk. MSIPS4W10 is the public catalog number, whereas S5EM077I10 is a custom order request for a specific customer.

      Helpful?

Reviews

Active Filters

  1. Boston, MA
    • Reviews 2
    • Votes 2
    5 out of 5 stars.

    Great plate for ELISPOTS

    These plates give a strong ELISPOT signal with very low background and work well with either a vacuum manifold plate washing apparatus or manual washing.

    Helpful?

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica