Cassetta Pellicon® 2 Modulo per ultrafiltrazione Biomax®

filtration area 0.5 m2, NMWCO 100 kDa

Sinonimo/i:

Pellicon® 2 Cassette Ultrafiltration Module Biomax-100 V 0.5 m2

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

Prezzi e disponibilità al momento non sono disponibili

Informazioni su questo articolo

Codice UNSPSC:
23151806

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Materiali

polyethersulfone
polypropylene screen
polyurethane adhesive

Livello qualitativo

Produttore/marchio commerciale

Pellicon®

Parametri

0.33 bar max. transmembrane pressure (5 psig) (reverse)
5-35 L/min recirculation rate at 0.4 bar (6 psi)
7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

tecniche

analytical sample preparation: suitable
protein purification: suitable

Altezza

2.16 cm (0.85 in.)

Lunghezza

21 cm (8.3 in.)

Larghezza

17.8 cm (7.0 in.)

Superficie filtrante

0.5 m2

Area nominale della membrana

0.5 m2

Estraibili (gravimetria)

≤1500 mg/m2

Matrice

Biomax®

Dimensione pori

100 kDa NMWCO

pH

1-14

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
P2B100C05P2B100A05P2B300C05
matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

pore size

100 kDa NMWCO

pore size

100 kDa NMWCO

pore size

100 kDa NMWCO

pore size

300 kDa NMWCO

material

polyethersulfone , polyurethane adhesive, polypropylene screen

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

technique(s)

analytical sample preparation: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward), 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 4-6 L/min recirculation rate at 1.4 bar (20 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

Descrizione generale

The Pellicon® 2 Ultrafiltration BIOMAX 100 Cassette sets the standard in cassette-style tangential flow filtration devices. P2B100V05 was designed with process scale-up and applications development in mind.

Millipore′s BIOMAX 100 polyethersulfone membrane has void-free structures that guard against leakage of solutes through microdefects normally associated with voids beneath the thin skins of conventional UF membranes. These void-free membranes are more permeable, resulting in high-flux with equivalent or superior product retention. These void-free membranes provide the advantages of fast, high yield processing and smaller systems.

The Pellicon® 2 Cassette Ultrafiltration BIOMAX Module feature a filtration area of 0.5 m2 with a pore size of 100 kDa NMWCO.

Applicazioni

Concentration, desalting or buffer exchange of:
  • Protein solutions
  • Polysaccharide solutions
  • Virus suspensions


Harvest, washing or clarification of:
  • Cell cultures and lysates
  • Colloidal suspensions
  • Viral cultures

Caratteristiche e vantaggi

  • Type V screen (open channel)
  • Leading-edge void- free membranes to match virtually any separation challenge
  • Short flow path for higher flux and higher resolution separation capability
  • Choice of flow channel configuration providing process optimization capability
  • Predictable, fast, scale-up
  • True linear scalability from laboratory size modules to industrial assemblies for processing thousands of liters
  • Brings higher resolution, improved yields and superior back-pressure resistance
  • Ultracel membranes are composite membranes cast on a microporous substrate for defect-free membranes with superior

Risultati analitici

Gravimetric Extractables: after a water flush

Altre note

Prefiltration Rquirements: 100 µm
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Note legali

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany

Codice della classe di stoccaggio

10 - Combustible liquids

Classe di pericolosità dell'acqua (WGK)

WGK 2


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Questions

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica