Passa al contenuto
Merck
  • Rapid, sensitive and selective HPLC-MS/MS method for the quantification of topically applied besifloxacin in rabbit plasma and ocular tissues: Application to a pharmacokinetic study.

Rapid, sensitive and selective HPLC-MS/MS method for the quantification of topically applied besifloxacin in rabbit plasma and ocular tissues: Application to a pharmacokinetic study.

Journal of pharmaceutical and biomedical analysis (2015-09-05)
Xiao-Fei Gu, Bai-Yang Mao, Min Xia, Yang Yang, Jia-Li Zhang, Da-Song Yang, Wei-Xin Wu, Ying-Xiang Du, Bin Di, Meng-Xiang Su
ABSTRACT

Besifloxacin is a fourth-generation broad-spectrum fluoroquinolone registered for the topical treatment of bacterial conjunctivitis. In this study, a rapid, sensitive and selective liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for quantification of besifloxacin in rabbit plasma and ocular tissues using nateglinide as the internal standard (IS). The analyte and IS were separated on a Sepax GP-Phenyl column by isocratic elution with methanol-acetonitrile-5 mM ammonium formate-formic acid (29:55:16:0.1, v/v/v/v) as the mobile phase at a flow rate of 1.2 mL/min, and the total run time was 3.0 min. An electrospray ionization (ESI) source was applied and operated in the positive ion mode; multiple reaction monitoring (MRM) mode was used for quantification, and the monitored transitions were 394.2→377.1 for besifloxacin and m/z 318.3→166.1 for the IS. The calibration curve was linear over the range of 0.103-206 ng/mL for plasma and 2.06-2060 ng/mL for tears, aqueous humor, conjunctiva and cornea with correlation coefficient (r) greater than 0.99. The lower limit of quantification (LLOQ) for besifloxacin was 0.103 ng/mL for plasma and 2.06 ng/mL for other ocular tissues with good accuracy and precision. Intra- and inter-batch precision were both lower than 15% and accuracy ranged from 85% to 115% at all QC levels. The method was successfully applied to the pharmacokinetic study of besifloxacin in rabbit plasma and ocular tissues after single and multiple topical administrations.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Acido formico, reagent grade, ≥95%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acido formico, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acido formico, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Metanolo, anhydrous, 99.8%
Sigma-Aldrich
Formato di ammonio, reagent grade, 97%
Sigma-Aldrich
Acido formico, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanolo, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Formato di ammonio, ≥99.995% trace metals basis
Sigma-Aldrich
Acido formico, ACS reagent, ≥88%
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Acido formico, ≥95%, FCC, FG
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Metanolo, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Metanolo, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Acetonitrile, ≥99.8% (GC)