Passa al contenuto
Merck
  • Online background cleanup followed by high-performance liquid chromatography with tandem mass spectrometry for the analysis of perfluorinated compounds in human blood.

Online background cleanup followed by high-performance liquid chromatography with tandem mass spectrometry for the analysis of perfluorinated compounds in human blood.

Journal of separation science (2014-11-12)
Liangpo Liu, Jianwen She, Xueqin Zhang, Jie Zhang, Meiping Tian, Qingyu Huang, Syed Ali Musstjab Akber Shah Eqani, Heqing Shen
ABSTRACT

In this study, a novel method for the analysis of perfluorinated compounds in whole blood has been developed and validated. The method was developed by using a conventional reversed-phase C18 column as a trapping column for the elimination of background contamination and high-performance liquid chromatography with tandem mass spectrometry for the target compounds analysis. The trapping column provided fast online separation of the background contamination of perfluorinated compounds. In this developed method, the limits of detection for different perfluorinated compounds ranged from 0.06 to 0.14 ng/mL. It is notable that the limit of detection (0.07 ng/mL) for perfluorooctanoic acid was improved significantly after the elimination of background contamination. The method was also validated in terms of sensitivity, accuracy, and precision. The recoveries ranged from 66.8 to 111.9%, with relative standard deviations from 2.1 to 15.3%. Our preliminary data suggest that the novel method based on trapping column cleanup followed by high-performance liquid chromatography with tandem mass spectrometry could be applied in studies on the human exposure to perfluorinated compounds.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
ter-butil metil etere, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Ammonio acetato, ACS reagent, ≥97%
Sigma-Aldrich
ter-butil metil etere, ACS reagent, ≥99.0%
Sigma-Aldrich
ter-butil metil etere, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Ammonio acetato, ≥99.99% trace metals basis
Supelco
Ammonio acetato, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Acido eptafluorobutirrico, 98%
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Perfluorooctanoic acid, 95%
Sigma-Aldrich
Zirconyl chloride octahydrate, reagent grade, 98%
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Ammonio acetato, Molecular Biology, ≥98%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
ter-butil metil etere, reagent grade, ≥98%
Supelco
Acido eptafluorobutirrico, suitable for ion chromatography, ≥99.5% (GC)
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Ammonium acetate solution, Molecular Biology, 7.5 M
USP
Metanolo, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
2-Thiobarbituric acid, ≥98%
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Supelco
Metanolo, analytical standard
Sigma-Aldrich
Ammonio acetato, 99.999% trace metals basis
Supelco
Metanolo, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Perfluorononanoic acid, 97%
Supelco
Heptadecafluorooctanesulfonic acid solution, 100 μg/mL in methanol, analytical standard
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%