コンテンツへスキップ
Merck
  • Quantification of cocaine and metabolites in exhaled breath by liquid chromatography-high-resolution mass spectrometry following controlled administration of intravenous cocaine.

Quantification of cocaine and metabolites in exhaled breath by liquid chromatography-high-resolution mass spectrometry following controlled administration of intravenous cocaine.

Analytical and bioanalytical chemistry (2014-08-19)
Kayla N Ellefsen, Marta Concheiro, Olof Beck, David A Gorelick, Sandrine Pirard, Marilyn A Huestis
要旨

Breath has been investigated as an alternative matrix for detecting recent cocaine intake; however, there are no controlled cocaine administration studies that investigated the drug's disposition into breath. Breath was collected from 10 healthy adult cocaine users by asking them to breathe into a SensAbues device for 3 min before and up to 22 h following 25 mg intravenous (IV) cocaine dosing on days 1, 5, and 10, and assayed with a validated liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method to quantify breath cocaine, benzoylecgonine (BE), ecgonine methyl ester (EME), and norcocaine. The assay was linear from 25 to 1,000 pg/filter, extraction efficiencies were 83.6-126%, intra- and inter-assay imprecision was <10.6%, and bias was between -8.5 and 16.8%. No endogenous or exogenous interferences were observed for more than 75 tested. Analytes were generally stable under short-term storage conditions. Ion suppression was less than 46%. Of breath specimens collected after controlled cocaine administration, 2.6% were positive for cocaine (26.1-66 pg/filter, 1-9.5 h), 0.72% BE (83.3-151 pg/filter, 6.5-12.5 h), and 0.72% EME (50-69.1 pg/filter, 6.5-12.5 h); norcocaine was not detected. Methanolic extraction of the devices themselves, after filters were removed, yielded 19.2% positive cocaine tests (25.2-36.4 pg/device, 10 min-22 h) and 4.3% positive BE tests (26.4-93.7 pg/device, 10 min-22 h), explaining differences between the two extraction techniques. These results suggest that the device reflects the drug in oral fluid as well as lung microparticles, while the filter reflects only drug-laden microparticles. A sensitive and specific method for cocaine, BE, EME, and norcocaine quantification in breath was developed and validated. Cocaine in breath identifies recent cocaine ingestion, but its absence does not preclude recent use.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, ≥99.9%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
水酸化アンモニウム 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
ギ酸, reagent grade, ≥95%
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
ギ酸, ACS reagent, ≥96%
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
ギ酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
水酸化アンモニウム 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Supelco
ギ酸アンモニウム, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
ギ酸アンモニウム, reagent grade, 97%
Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
アセトニトリル, ≥99.9% (GC)
Sigma-Aldrich
ギ酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
ギ酸アンモニウム, ≥99.995% trace metals basis
Sigma-Aldrich
ギ酸, ACS reagent, ≥88%
Sigma-Aldrich
水酸化アンモニウム 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
ギ酸アンモニウム 溶液, BioUltra, 10 M in H2O
Sigma-Aldrich
アセトニトリル, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
水酸化アンモニウム 溶液, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis