コンテンツへスキップ
Merck
  • The effects of electrolysis on operational solutions in electromembrane extraction: The role of acceptor solution.

The effects of electrolysis on operational solutions in electromembrane extraction: The role of acceptor solution.

Journal of chromatography. A (2015-05-06)
Pavel Kubáň, Petr Boček
要旨

Fundamental operational principle and instrumental set-up of electromembrane extraction (EME) suggest that electrolysis may play an important role in this recently developed micro-extraction technique. In the present study, the effect of electrolysis in EME is described comprehensively for the first time and it is demonstrated that electrolysis considerably influences EME performance. Micro-electromembrane extraction (μ-EME) across free liquid membrane formed by 1-pentanol was utilized for real-time monitoring of the electrolytically induced changes in composition of μ-EME solutions. These changes were visualized with a set of acid-base indicators. Changes in colours of their aqueous solutions revealed serious variations in their pH values, which occurred within seconds to minutes of the μ-EME process. Variations of up to eight pH units were observed for indicator solutions initially prepared in 1, 5 and 10mM hydrochloric acid. No or only negligible pH changes (less than 0.15 pH unit) were observed for indicator solutions prepared in 50 and 100mM acetic acid demonstrating that initial composition of the aqueous solutions was the crucial parameter. These results were also confirmed by theoretical calculations of maximum pH variations in the solutions, which were based on total electric charge transfers measured in the μ-EME systems, and by exact measurements of their pH values after μ-EMEs. Acceptor solutions that, in the current practice, consist predominantly of low concentrations of strong mineral acids or alkali hydroxides may thus not always ensure adequate EME performance, which was manifested by decrease in extraction recoveries of a basic drug papaverine. A suitable remedy to the observed effects is the application of acceptor solutions containing high concentrations of weak acids or bases. These solutions not only eliminate the decrease in recoveries but also serve well as matrices of extracted samples for subsequent analysis by capillary electrophoresis.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
酢酸, suitable for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
1-ペンタノール, ACS reagent, ≥99%
Sigma-Aldrich
5α-アンドロスタン-17β-オール-3-オン, ≥97.5%
Sigma-Aldrich
酢酸, ≥99.7%
Sigma-Aldrich
パパベリン 塩酸塩, powder
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
ギ酸, ≥95%, FCC, FG
Sigma-Aldrich
酢酸, ≥99.5%, FCC, FG
Sigma-Aldrich
アミルアルコール, ≥99%, FG
Sigma-Aldrich
酢酸, natural, ≥99.5%, FG
Sigma-Aldrich
酢酸, JIS special grade, ≥99.7%
Sigma-Aldrich
メタノール, SAJ special grade
Sigma-Aldrich
1-ペンタノール, puriss. p.a., ACS reagent, ≥99.0% (GC)
Sigma-Aldrich
酢酸 溶液, 1 N, 1 M
Sigma-Aldrich
ギ酸, JIS special grade, ≥98.0%
Sigma-Aldrich
酢酸, SAJ first grade, ≥99.0%
Sigma-Aldrich
5α-アンドロスタン-17β-オール-3-オン, purum, ≥99.0% (TLC)
Sigma-Aldrich
メタノール, suitable for HPLC
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%, poly-coated bottles
Supelco
メタノール 溶液, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
酢酸, ≥99.7%, SAJ super special grade
Sigma-Aldrich
メタノール, suitable for NMR (reference standard)
Sigma-Aldrich
酢酸, ≥99.7%, for titration in non-aqueous medium
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
メタノール, JIS 300, ≥99.8%, suitable for residue analysis
Sigma-Aldrich
酢酸, 99.5-100.0%
Sigma-Aldrich
1-ペンタノール, SAJ special grade, ≥99.0%
Sigma-Aldrich
ギ酸, SAJ first grade, 88.0-89.5%