콘텐츠로 건너뛰기
Merck

KVEPS015FB3

Millipore Express® SHR 0.1µm, Opticap® XL 150 Capsule

Fittings 3/4 in. TC- 9/16 in. HB with Bell, Sterile

로그인 조직 및 계약 가격 보기

크기 선택

가격 및 재고 정보를 현재 이용할 수 없음

제품정보 (DICE 배송 시 비용 별도)

UNSPSC 코드:
23151806

다음으로 건너뛰기

기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

제품 이름

Millipore Express® SHR, Opticap® XL Capsule, sterile, Opticap® XL 150, cartridge nominal length 3.8 in. (9.7 cm), filter diam. 5.6 cm (2.2 in.)

material

polyethylene support
polypropylene device
polypropylene housing
polypropylene vent cap
silicone seal

Quality Level

규정 준수

meets FDA 21 CFR 177-182 (all component materials)

무균

irradiated
sterile

제품 라인

Opticap® XL 150

특징

hydrophilic

제조업체/상표

Millipore Express®

파라미터

≤1.4 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

기술

sterile filtration: suitable

카트리지 공칭 길이

3.8 in. (9.7 cm)

장치 길이

9.7 cm (3.8 in.)

필터 직경

5.6 cm (2.2 in.)

필터 여과 영역

250 cm2

불순물

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)

Matrix

Millipore Express® SHR

공극 크기

0.1 μm pore size

버블 포인트(bubble point)

≥4000 mbar (58 psig), air with water

피팅

(19 mm (¾ in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet with filling bell)

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Device Configuration: Capsule

포장

Double Easy-Open bag

제조 메모

Sterilization Method:
3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

분석 메모

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
TOC/Conductivity: After sterilization and a controlled water flush of 2.0 L, samples exhibited &#x3C 500 ppb TOC per USP &#x3C 643 &#x3C and &#x3C 1.3 μS/cm per USP &#x3C 645 &#x3C at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 1 L

기타 정보

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

법적 정보

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Emprove® 프로그램을 사용하여 GMP 준수 유지

Emprove® Dossiers로 자격을 가속화하고, 규정 준수를 유지하며, 시간을 절약하세요.

Dossiers 다운로드

주: EmproveSuite.com으로 이동하게 됩니다. 귀하의 사용자 이름과 비밀번호는 시그마알드리치닷컴과는 별개이며 다를 수 있습니다.

무료로 등록하고 몇 분 안에 Emprove® Dossiers에 액세스하세요. 구독 플랜을 업그레이드하여 Emprove® Suite에서 고급 및 맞춤형 콘텐츠를 잠금 해제하세요.