Saltar al contenido
Merck

1.01518

Nitric acid

60%, Ultrapur

Sinónimos:

Ácido nítrico solution

Iniciar sesión para ver los posibles precios especiales de su organización

Seleccione un Tamaño

1 L

MXP 38,059.00

MXP 38,059.00


Comprobar disponibilidad del carrito

Solicite una orden a granel

Acerca de este artículo

Fórmula empírica (notación de Hill):
HNO3
Número CAS:
Peso molecular:
63.01
MDL number:
UNSPSC Code:
12352301
NACRES:
NB.21

Saltar a

Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

Nombre del producto

Ácido nítrico al 60%, Ultrapur

agency

suitable for EPA 200.7
suitable for EPA 200.8

Quality Level

description

for inorganic trace analysis

assay

60%

form

liquid

concentration

60%

pH

<1 (20 °C in H2O)

bp

120 °C/1013 hPa

mp

-22 °C

solubility

water: soluble

density

1.37 g/cm3 at 20 °C

storage temp.

2-30°C

SMILES string

O[N+]([O-])=O

InChI

1S/HNO3/c2-1(3)4/h(H,2,3,4)

InChI key

GRYLNZFGIOXLOG-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Categorías relacionadas

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
1.004411.0045684380
grade

for inorganic trace analysis

grade

for inorganic trace analysis

grade

-

grade

-

assay

60%

assay

65%

assay

≥65.0% (alkalimetric)

assay

≥65% (T)

Quality Level

100

Quality Level

100

Quality Level

300

Quality Level

100

agency

suitable for EPA 200.7, suitable for EPA 200.8

agency

suitable for EPA 200.7, suitable for EPA 200.8

agency

reag. ISO, reag. Ph. Eur.

agency

-

form

liquid

form

liquid

form

liquid

form

liquid

pH

<1 (20 °C in H2O)

pH

<1 (20 °C in H2O, strongly acid)

pH

<1 (20 °C in H2O, strongly acid)

pH

<1.0

pictograms

Skull and crossbonesCorrosion

signalword

Danger

Hazard Classifications

Acute Tox. 3 Inhalation - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

supp_hazards

Clase de almacenamiento

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

Analysis of heavy metals and metals in cannabis and hemp containing personal care products and cosmetics include sample preparation by grinding, preparation of calibration solutions for a standard addition approach, a microwave digestion protocol and subsequent ICP-MS analysis.

A 4-step comprehensive ICP-MS workflow including sample homogenization, with standard addition calibration method, to determine heavy metals in Cannabis sativa.

ICP-MS analyzes 12 heavy metals in hemp-containing food samples using standard addition calibration for accurate quantification.

Contenido relacionado

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. E' adatto per analisi in ICP-MS?

    1 answer
    1. Yes, this product is suitable for use in inductively coupled plasma-mass spectrometry (ICP-MS) analysis. Ultrapur grade acids and bases meet the highest demands of all users for ultra-trace instrumental analysis in the parts per trillion (ppt) range, e.g. ICP-MS.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico