Skip to Content
Merck

1.00030

Acetonitrile

≥99.9% (GC), gradient grade, suitable for HPLC, Reag. Ph Eur, LiChrosolv®

Synonym(s):

ACN, Cyanomethane, Ethyl nitrile, Methyl cyanide

Sign In to View Organizational & Contract Pricing

Select a Size

Pricing and availability is not currently available.

About This Item

Linear Formula:
CH3CN
CAS Number:
Molecular Weight:
41.05
Beilstein:
741857
MDL number:
UNSPSC Code:
12191502
EC Index Number:
200-835-2
NACRES:
NA.03
Grade:
gradient grade
Assay:
≥99.9% (GC)
≥99.9%
Technique(s):
HPLC: suitable
Bp:
81-82 °C (lit.)
Vapor pressure:
72.8 mmHg ( 20 °C)
97 hPa ( 20 °C)

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Acetonitrile, gradient grade for liquid chromatography LiChrosolv® Reag. Ph Eur

grade

gradient grade

Quality Level

Agency

reag. Ph. Eur.

vapor density

1.41 (vs air)

vapor pressure

72.8 mmHg ( 20 °C)
97 hPa ( 20 °C)

description

(Absorbance (at 200 nm) <=0.1


Absorbance (from 240 nm) <=0.01)

product line

LiChrosolv®

Assay

≥99.9% (GC)
≥99.9%

form

liquid

autoignition temp.

524 °C
973 °F

expl. lim.

16 %

technique(s)

HPLC: suitable

impurities

≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.02% Water

evapn. residue

≤2.0 mg/L

color

APHA: ≤10

transmittance

193 nm, ≥60%
195 nm, ≥80%
230 nm, ≥98%

refractive index

n/D 1.344
n20/D 1.344 (lit.)

bp

81-82 °C (lit.)

mp

−45 °C (lit.)

transition temp

flash point 2 °C

density

0.786 g/mL at 25 °C (lit.)
0.78-20 °C

format

neat

storage temp.

2-30°C

SMILES string

CC#N

InChI

1S/C2H3N/c1-2-3/h1H3

InChI key

WEVYAHXRMPXWCK-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.142911.133581.00665
grade

gradient grade

grade

HPLC grade, isocratic

grade

for chromatography, for preparative HPLC, for preparative liquid chromatography

grade

-

Quality Level

200

Quality Level

100

Quality Level

200

Quality Level

100

assay

≥99.9% (GC)

assay

≥99.8% (GC)

assay

≥99.8% (GC)

assay

≥99.8% (GC)

technique(s)

HPLC: suitable

technique(s)

HPLC: suitable

technique(s)

-

technique(s)

GC/MS: suitable

form

liquid

form

liquid

form

liquid

form

liquid

impurities

≤0.0002 meq/g Acidity, ≤0.02% Water, ≤0.0002 meq/g Alkalinity

impurities

≤0.0002 meq/g Alkalinity, ≤0.0005 meq/g Acidity, ≤0.05% Water

impurities

≤0.0002 meq/g Alkalinity, ≤0.0005 meq/g Acidity, ≤0.05% Water

impurities

≤0.05% Water

General description

LiChrosolv® solvents were specially formulated to meet the demanding needs of analytical HPLC applications. With exceptional UV transmittance, minimal particle count, and controlled acidity and alkalinity, our solvents ensure reproducible separations every time. The low evaporation residue level further enhances their performance, making them the ideal choice for high-quality results. The product line includes both "gradient grade" and "isocratic grade" solvents, specifically designed to reduce the gradient effect during separations. This tailored approach allows for optimal consistency and accuracy in your analytical processes, helping you achieve the best possible outcomes in your chromatography work.

Now Available with Data Matrix Code
This high-quality HPLC-grade solvent now features a unique Data Matrix Code on its label, providing digital access to essential product information such as batch number, product number, and expiry date. Unlike standard barcodes, our DMCs feature a unique serial number for each bottle, enabling you to monitor and trace every bottle individually. With standard barcodes, all bottles from the same batch look identical. Our solution gives you true bottle-level traceability for greater control and compliance in the lab.
Know more about our data matrix code-labeled HPLC-grade solvents.

Application

  • Reversed-Phase HPLC: Commonly used as a mobile phasecomponent for the separation of a wide range of compounds, includingpharmaceuticals, environmental pollutants, and biomolecules.
  • Gradient Elution: Ideal for gradient elutiontechniques, enhancing the resolution and separation efficiency of complexmixtures.
  • Pharmaceutical Analysis: Frequently employed in theanalysis of active pharmaceutical ingredients (APIs) and their impurities,ensuring compliance with regulatory standards.
  • Biological Sample Analysis: Used for the analysis ofproteins, peptides, and metabolites in biological samples, facilitatingaccurate quantification and identification.
  • Environmental Monitoring: Applied in the HPLCanalysis of environmental samples to detect and quantify contaminants in water,soil, and air.

Features and Benefits

  • High Purity: Formulated with minimal impurities, ensuring reliable and reproducible results essential for sensitive analytical applications.
  • Excellent UV Transparency: Provides optimal UV transmittance, facilitating accurate detection and enhancing sensitivity in HPLC analyses.
  • Low Evaporation Residue: Minimizes contamination risk, leading to cleaner separations and improved analytical reliability.
  • Batch-to-Batch Consistency: Ensures uniform quality and performance across different production batches, enhancing reproducibility and confidence in analytical results.

Preparation Note

Microfiltered by 0.2 μm filter

Other Notes

Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

Legal Information

LICHROSOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictograms

FlameExclamation mark

Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

35.6 °F - closed cup

Flash Point(C)

2.0 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Determination of bisphenol A in tea samples by solid phase extraction and liquid chromatography coupled to mass spectrometry.
Ala A S, et al.
Microchemical Journal, Devoted to the Application of Microtechniques in All Branches of Science, 147, 598-604 (2019)
An assessment of indoor air concentrations and health risks of volatile organic compounds in three primary schools.
Sait S C, et al.
International Journal of Hygiene and Environmental Health, 214, 36-46 (2011)

Articles

Quantitative HPLC-UV analysis of honokiol, magnolol, and glycyrrhizic acid in Huoxiang Zhengqi Shui following the Chinese Pharmacopoeia draft.

Method development for HPLC-UV quantification of tanshinone IIA and key ginsenosides in Guanxin Danshen Diwan as per the Chinese Pharmacopoeia draft.

Related Content

Optimize your laboratory workflows with serialized DMC-labeled HPLC-grade solvents for improved tracking, regulatory compliance, and process optimization.

United States Pharmacopeia Methods - Olmesartan

United States Pharmacopeia Methods - Lansoprazole

See All

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Hi There, We receive product code 1.00030.2500. Id like to know please can you tell me exactl what is the glass type used for this product, Thank you Sean

    1 answer
    1. The bottle for 1.00030.2500 is made of borosilicate amber glass to minimize contamination from metal ions.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service