Przejdź do zawartości
Merck

Przejdź do

P3C030D10

Pellicon® 3 Cassette with Ultracel® Membrane

filtration area 1.14 m2, NMWCO 30 kDa, Holdup volume 227 mL

Synonim(y):

Pellicon® 3 Cassette with Ultracel 30 kDa Membrane, D screen, 1.14 m2, Pellicon® 3 Ultracel® Membrane Cassette, Pellicon® 3 Ultrafiltration Cassette

Zaloguj się, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

Zmień widok
Rozmiar/SKUDostępnośćCena netto
1 ea

Przewidywany termin wysyłki29 grudnia 2026zKuehne + Nagel Sp. z o.o.

34 040,00 zł

Informacje o tej pozycji

eCl@ss:
32031602
UNSPSC Code:
41104903

34 040,00 zł


Przewidywany termin wysyłki29 grudnia 2026Szczegóły


​
Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc


Quality Segment

material

TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)

product line

Pellicon®

feature

holdup volume 227 mL (in feed channel)

manufacturer/tradename

Pellicon®

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration), tangential flow filtration (TFF): suitable

H

4.1 cm (1.63 in.)

L

20.6 cm (8.1 in.)

W

17.8 cm (7 in.)

filtration area

1.14 m2

membrane area

1.14 m2

gravimetric extractables

≤1500 mg/m2

matrix

Ultracel® (Membrane)

pore size

30 kDa NMWCO

pH

2-13

application(s)

mAb
recombinant protein

General description

The Pellicon® 3 Cassette with Ultracel® membrane is a high performance tangential flow filtration (TFF) device designed to support efficient ultrafiltration and diafiltration of therapeutic antibodies and other biologics. This cassette is manufactured for high product recovery, reliable flux performance, and robust cleanability. It reduces processing time while maintaining product quality. Its durable construction enables operation under demanding process conditions, including elevated pressures, and temperatures, making it an ideal choice for today′s high-titer bioprocessing applications.

Application

Pellicon® 3 Cassettes with Ultracel® 30kD Membrane D screen is manufactured to efficiently process high viscosity products. These cassettes can achieve higher concentration therapeutic protein formulations by maximizing mass transfer and managing the pressure drop created by higher viscosity. From process development through commercial production, these cassettes deliver reliable performance across various filtration applications, including:
  • High fouling mAb
  • Recombinant and non-recombinant proteins
  • Plasma
  • vaccine process streams

Features and Benefits

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Analysis Note

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Other Notes

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

Legal Information

Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 1

Ta pozycja
P3C030C01P3C010C10P3C005C05
description

filtration area 1.14 m2, NMWCO 30 kDa, Holdup volume 227 mL

description

filtration area 0.11 m2, NMWCO 30 kDa, Holdup volume 18 mL

description

filtration area 1.14 m2, NMWCO 10 kDa, Holdup volume 170 mL

description

filtration area 0.57 m2, NMWCO 5 kDa

pore size

30 kDa NMWCO

pore size

30 kDa NMWCO

pore size

10 kDa NMWCO

pore size

5 kDa NMWCO

technique(s)

protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable

technique(s)

buffer exchange: suitable, protein purification: suitable (concentration), analytical sample preparation: suitable

technique(s)

protein purification: suitable (concentration), buffer exchange: suitable, analytical sample preparation: suitable

filtration area

1.14 m2

filtration area

0.11 m2

filtration area

1.14 m2

filtration area

0.57 m2

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

material

stainless steel cap (for end; polypropylene-encapsulated), composite regenerated cellulose (CRC) , polypropylene screen, TPE seal

material

TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, polypropylene cap (for end)

material

composite regenerated cellulose (CRC) , stainless steel cap (for end; polypropylene-encapsulated), TPE seal, polypropylene screen

material

stainless steel cap (for end; polypropylene-encapsulated), TPE seal, polypropylene screen, composite regenerated cellulose (CRC)

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C, 6.9 bar max. inlet pressure (100 psi)

parameter

6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C

parameter

4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours)

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C


Still not finding the right product?


Klasa składowania

10 - Combustible liquids

Co się dzieje?

WGK 2


Wykazy regulacyjne

Wykazy regulacyjne dotyczą głównie produktów chemicznych. Można w nich podawać ograniczoną liczbę informacji na temat produktów niechemicznych. Brak wpisu oznacza, że żaden ze składników nie znajduje się w wykazie. Użytkownik odpowiada za zagwarantowanie bezpiecznego i zgodnego z prawem stosowania produktu.

64-19-7

CAS No.


Zgodność z GMP dzięki programowi Emprove®

Przyspiesz kwalifikacje, zachowaj zgodność i oszczędzaj czas dzięki Emprove® Dossiers.

Pobierz Dossiers

Uwaga: zostaniesz przeniesiony do EmproveSuite.com. Twoja nazwa użytkownika i hasło są niezależne od SigmaAldrich.com i mogą się różnić.

Zarejestruj się za darmo i uzyskaj dostęp do Emprove® Dossiers w ciągu kilku minut. Uaktualnij swój plan subskrypcji, aby odblokować zaawansowaną i spersonalizowaną zawartość w Emprove® Suite.

Nie znalazłeś tego, czego szukasz? Odwiedź stronę pomocy programu Emprove®..

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Masz trudności ze znalezieniem produktu lub numeru serii/partii?

Podczas wyświetlania na stronie internetowej numery produktów są łączone z wielkością przesyłki / ilością (przykład: T1503-25G). Pamiętaj że w polu „Numer produktu” należy podać TYLKO numer produktu (przykład: T1503).

Przykład:

T1503
Numer produktu
-
25G
Wielkość opakowania/ilość

Przykłady dodatkowe:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

wpisz jako 1.000309185)

Mieć kłopoty? Poczuj się swobodnie w kontakcie Pomoc techniczna dla wsparcia



Questions

Reviews

No rating value

Active Filters