Przejdź do
Wybierz wielkość
| Rozmiar/SKU | Dostępność | Cena netto |
|---|---|---|
20 reactions | Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności | 342,00 zł |
100 reactions | Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności | 1280,00 zł |
400 reactions | Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności | 4290,00 zł |
Informacje o tej pozycji
342,00 zł
Quality Segment
form
liquid
usage
sufficient for 100 reactions, sufficient for 20 reactions, sufficient for 400 reactions
feature
dNTPs included, hotstart
concentration
2.5 units/reaction (50 μL reaction volume)
technique(s)
RT-qPCR: suitable, qPCR: suitable, whole genome amplification: suitable
color
colorless
input
purified DNA
application(s)
agriculture
compatibility
Bio-Rad MyiQ ( ), Bio-Rad iCycler iQ, Bio-Rad iQ 5, for use with ABI 5700, for use with ABI 7000, for use with ABI 7300, for use with ABI 7500 Fast, for use with ABI 7500, for use with ABI 7700, for use with ABI 7900 Fast, for use with ABI 7900 HT, for use with ABI 7900, for use with ABI StepOne, for use with ABI StepOnePlus, for use with ABI ViiA 7, for use with Bio-Rad CFX384, for use with Bio-Rad CFX96, for use with Bio-Rad MJ Chromo4, for use with Bio-Rad MJ Opticon 2, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Bio-Rad MJ Opticon, for use with Bio-Rad MiniOpticon, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Eppendorf® Mastercycler ep realplex, for use with Illumina Eco qPCR, for use with Qiagen Corbett Rotor-Gene 3000, for use with Qiagen Corbett Rotor-Gene 6000, for use with Qiagen Corbett Rotor-Gene Q, for use with Roche LightCycler 480, for use with Strategene Mx3000P, for use with Strategene Mx3005P, for use with Strategene Mx4000
detection method
probe-based
shipped in
wet ice
storage temp.
−20°C
General description
Application
- for quantitative polymerase chain reaction (qPCR) amplification of HIV-1 RNA that is reverse transcribed and DNA using probes
- in a 2-step RT-qPCR assay for the quantification of reverse transcribed RNA in a study to monitor the activity of licorice in Treg cell differentiation and function
- as a component of the reaction mixture for the detection and amplification of Salmonella sp. and internal amplification control (IAC) pUC 19 plasmid DNA
- as a component of the reaction mixture for the detection of Clostridium difficile by quantitative polymerase chain reaction (qPCR)
- for quantitative real-time -PCR of reverse-transcribed ß-arrestin-1 (ARRB1) and β-arrestin-2 (ARRB2) mRNA
Biochem/physiol Actions
Features and Benefits
- Ultimate Convenience: ReadyMixes contain all components necessary for QPCR, simply add fluorescent detection chemistry, primers, and template
- Greater Specificity & Increased Target Yield: JumpStart™ Taq prevents non-specific amplification and increased target yield
- Maximum Flexibility: Suitable for use with a variety of detection chemistries including molecular probes and double-stranded binding dyes such as SYBR™ Green I
- Designed for use with either plate/tube real-time thermal cyclers or capillary instruments
Packaging
Default reaction volume is 50 μL
20RXN is packaged as 1 X 500 μL
100RXN is packaged as 1 X 2.5 mL
400RXN is packaged as 1 X 10 mL
Other Notes
Legal Information
This product is an Authorized 5′ Nuclease Core Kit. Use of this product is covered by one or more of the following claims outside the US corresponding to US Patent No. 5,210,015 and 5,487,972. The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchaser′s own internal research. Separate purchase of a Licensed Probe would convey rights under US Patents and corresponding patent claims outside the US: 5,538,848, 5,723,591, 5,876,930, 6,030,787, 6,258,569, 5,804,375 (claims 1-12 only), and and claims outside the United States corresponding to US Patent No. 6,214,979. No right under any other patent claim and no right to perform commercial services of any kind, including without limitation reporting the results of purchaser′s activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel. This product is for research use only. Diagnostic uses under Roche patents require a separate license from Roche. Further information on purchasing licenses may be obtained from the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA.
1 of 1
Ta pozycja | |||
|---|---|---|---|
| description For probe-based real-time PCR | description for quantitative PCR, MgCI2 in buffer | description for quantitative PCR, without MgCl2 in buffer | description One step RT-qPCR for probe-based methods, MMLV & hot-start Taq |
| technique(s) qPCR: suitable, whole genome amplification: suitable, RT-qPCR: suitable | technique(s) qPCR: suitable, RT-qPCR: suitable, whole genome amplification: suitable | technique(s) RT-qPCR: suitable, whole genome amplification: suitable | technique(s) qPCR: suitable, RT-qPCR: suitable, whole genome amplification: suitable |
| feature dNTPs included, hotstart | feature dNTPs included, hotstart | feature dNTPs included, hotstart | feature dNTPs included, hotstart |
| application(s) agriculture | application(s) agriculture | application(s) agriculture | application(s) - |
| concentration 2.5 units/reaction (50 μL reaction volume) | concentration 1.25 units/reaction (50 μL reaction volume) | concentration 1.25 units/reaction (50 μL reaction volume) | concentration - |
| input purified DNA | input purified DNA | input purified DNA | input purified RNA |
| compatibility Bio-Rad MyiQ ( ), for use with Bio-Rad MJ Opticon, for use with ABI StepOnePlus, for use with ABI ViiA 7, for use with Roche LightCycler 480, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Qiagen Corbett Rotor-Gene 3000, for use with ABI 7900, for use with ABI 7300, for use with Bio-Rad CFX96, for use with ABI 7900 HT, for use with ABI 7500, for use with Eppendorf® Mastercycler ep realplex, for use with ABI 7900 Fast, Bio-Rad iCycler iQ, for use with ABI 7700, for use with Qiagen Corbett Rotor-Gene Q, for use with Bio-Rad MiniOpticon, for use with Bio-Rad CFX384, for use with ABI 7000, for use with Bio-Rad MJ Opticon 2, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Strategene Mx3005P, for use with Strategene Mx4000, for use with Qiagen Corbett Rotor-Gene 6000, for use with ABI 7500 Fast, for use with Illumina Eco qPCR, for use with ABI 5700, for use with Bio-Rad MJ Chromo4, Bio-Rad iQ 5, for use with Strategene Mx3000P | compatibility Bio-Rad MiniOpticon, Roche LightCycler 480 , Strategene Mx3005P, ABI ViiA 7 , ABI 7900 HT, Cepheid SmartCycler, Strategene Mx3000P, Bio-Rad iCycler iQ, ABI StepOne, Strategene Mx4000, Bio-Rad MJ Opticon, ABI 7900 HT Fast, ABI StepOnePlus, ABI 7500, for use with ABI 5700, ABI 7500 Fast, Qiagen Corbett Rotor-Gene 3000, Eppendorf® Mastercycler ep realplex , Bio-Rad MJ Chromo4, Bio-Rad CFX384, ABI 7700, ABI 7000, Bio-Rad MyiQ, ABI 7300, Qiagen Corbett Rotor-Gene 6000, Eppendorf® Mastercycler ep realplex2 S, Bio-Rad iQ 5, Bio-Rad MJ Opticon 2 , Illumina Eco qPCR, Qiagen Corbett Rotor-Gene Q, Bio-Rad CFX96 | compatibility Bio-Rad iCycler iQ, for use with ABI 7500, for use with ABI 7000, for use with ABI 7900, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with ABI 7500 Fast, for use with ABI 7300, for use with Bio-Rad CFX384, for use with Illumina Eco qPCR, for use with ABI 5700, for use with ABI ViiA 7, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Strategene Mx4000, for use with Bio-Rad MiniOpticon, for use with Qiagen Corbett Rotor-Gene 6000, for use with Qiagen Corbett Rotor-Gene 3000, for use with Bio-Rad MJ Opticon 2, for use with ABI 7900 Fast, for use with Strategene Mx3000P, for use with Qiagen Corbett Rotor-Gene Q, Bio-Rad MyiQ, for use with ABI StepOne, for use with ABI 7700, for use with ABI 7900 HT, for use with Roche LightCycler 480, for use with Bio-Rad CFX96, for use with ABI StepOnePlus, for use with Bio-Rad MJ Chromo4, for use with Strategene Mx3005P, Bio-Rad iQ 5 | compatibility ABI 7500 Fast, ABI 7900, Strategene Mx3000P, ABI 7000, Bio-Rad iCycler iQ, Eppendorf® Mastercycler ep realplex, Cepheid SmartCycler, Bio-Rad MJ Opticon, ABI 5700, Bio-Rad MJ Opticon 2, Roche LightCycler 480, ABI ViiA 7, ABI 7900 HT Fast, ABI StepOne, Strategene Mx3005P, ABI StepOnePlus, Bio-Rad CFX96, Qiagen Corbett Rotor-Gene Q, Bio-Rad CFX384, Qiagen Corbett Rotor-Gene 3000, Bio-Rad MiniOpticon, Illumina Eco qPCR, Bio-Rad iQ5, Bio-Rad MyiQ, Eppendorf® Mastercycler ep realplex2 s, ABI 7700, Strategene Mx4000, ABI 7300, Bio-Rad MJ Chromo4, Qiagen Corbett Rotor-Gene 6000 |
Słowo ostrzegawcze
Warning
Kody zagrożeń
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1
Klasa składowania
12 - Non Combustible Liquids
Co się dzieje?
WGK 3
Wybierz jedną z najnowszych wersji:
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.