Przejdź do zawartości
Merck

The removal of Triton X-100 by dialysis is feasible!

Analytical and bioanalytical chemistry (2014-11-27)
Stefan Opitz, Franziska Hannika, Thomas Krüger, Heidrun Rhode
ABSTRAKT

Triton X-100 has been widely used in many analytical and preparative protocols for a long time. Nevertheless, mass spectrometry, chromatographic separation, and spectrophotometric readout may be considerably hampered by this detergent due to signal suppression, complex formation, and high blank values, respectively. Additionally, Triton X-100 is not safe to remove prior to analytics. Here, microdialysis is introduced as a parallelizable, high-throughput method to clean samples from Triton X-100 with high efficacy and precision. To achieve this, we exploit the potential to considerably increase the critical micellar concentration of Triton X-100 by alteration of matrix properties. To that end, addition of several chaotropic compounds and organic solvents has been shown to increase the critical micellar concentration as well as the removal rate of the detergent. For application, matrix additives can be selected for analyte stability requirements out of a variety of compounds. Conveniently, all these additives are removable subsequently using the same microdialysis tool for downstream analytics requirements. Applicability and protocols are shown with proteomic sample preparation of purified proteins and complex protein mixtures prior to matrix-assisted laser desorption ionization (MALDI) mass spectrometry.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
1-Propanol, ≥99%, FG
Sigma-Aldrich
Isopropyl alcohol, ≥99.7%, FCC, FG
Sigma-Aldrich
1-Propanol, natural, ≥98%, FG
Sigma-Aldrich
Nitrilotriacetic acid, BioUltra, ≥99.0% (T)
Sigma-Aldrich
Water, Molecular Biology, sterile filtered
Sigma-Aldrich
Water, tested according to Ph. Eur.
Sigma-Aldrich
Water, for cell biology, sterile ultrafiltered
Sigma-Aldrich
Urea-12C, 99.9 atom % 12C
Sigma-Aldrich
E-Toxate Water, endotoxin, free
Sigma-Aldrich
Water, for embryo transfer, sterile-filtered, BioXtra, suitable for mouse embryo cell culture
Sigma-Aldrich
Urea solution, 40 % (w/v) in H2O
Supelco
1-Propanol, analytical standard
Supelco
Methanol, analytical standard
Sigma-Aldrich
Urea solution, BioUltra, ~8 M in H2O
Sigma-Aldrich
DL-Dithiothreitol solution, BioUltra, Molecular Biology, ~1 M in H2O
Sigma-Aldrich
Water, PCR Reagent
Sigma-Aldrich
Nitrilotriacetic acid, Sigma Grade, ≥99%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Water, BioPerformance Certified
Supelco
Water, ACS reagent, for ultratrace analysis
Supelco
DL-Dithiothreitol solution, 1 M in H2O
Supelco
Water, suitable for ion chromatography
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Water, ACS reagent
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%