Größe auswählen
Über diesen Artikel
Fortfahren mit
Qualitätsniveau
Assay
≥99.0% (acidimetric)
Form
solid
pH-Wert
9.1 (20 °C, 100 g/L in H2O, slurry)
mp (Schmelzpunkt)
930 °C
Löslichkeit
141.2 g/L
Dichte
2.35 g/cm3 at 20 °C
Schüttdichte
330 kg/m3
Anionenspuren
chloride (Cl-): ≤50 ppm
phosphate (PO43-): ≤20 ppm
silicate (as SiO2): ≤100 ppm
sulfate (SO42-): ≤50 ppm
Kationenspuren
Ag: ≤5 ppm
Al: ≤10
Ba: ≤5 ppm
Ca: ≤20 ppm
Cd: ≤5 ppm
Co: ≤5 ppm
Cr: ≤5 ppm
Cu: ≤5 ppm
Fe: ≤10 ppm
Ga: ≤5 ppm
K: ≤10 ppm
Mg: ≤5 ppm
Mn: ≤5 ppm
Na: ≤20 ppm
Ni: ≤5 ppm
Pb: ≤5 ppm
Sr: ≤5 ppm
Zn: ≤5 ppm
Lagertemp.
2-30°C
SMILES String
[B].[B].[B].[B].[Li].[Li].O.O.O.O.O.O.O
InChI
1S/4B.2Li.7H2O/h;;;;;;7*1H2
InChIKey
DPYKRXYVXDYLEY-UHFFFAOYSA-N
1 of 4
Dieser Artikel | 1.12630 | 1.11802 | 1.13175 |
|---|---|---|---|
| form solid | form solid | form solid | form solid |
| solubility 141.2 g/L | solubility 141.2 g/L, water: 141.2 g/L at 20 °C (68 °F - OECD Test Guideline 105) | solubility 50 g/L | solubility 50 g/L |
| assay ≥99.0% (acidimetric) | assay ≥99.0% (acidimetric) | assay - | assay ≥99.0% (acidimetric) |
| Quality Level 100 | Quality Level 100 | Quality Level 100 | Quality Level 100 |
| grade for X-ray fluorescence analysis | grade for X-ray fluorescence analysis | grade for X-ray fluorescence analysis | grade for X-ray fluorescence analysis |
| cation traces Ag: ≤5 ppm, Ba: ≤5 ppm, Cd: ≤5 ppm, Cr: ≤5 ppm, Fe: ≤10 ppm, K: ≤10 ppm, Mn: ≤5 ppm, Ni: ≤5 ppm, Sr: ≤5 ppm, Al: ≤10, Co: ≤5 ppm, Ga: ≤5 ppm, Na: ≤20 ppm, Zn: ≤5 ppm, Ca: ≤20 ppm, Mg: ≤5 ppm, Cu: ≤5 ppm, Pb: ≤5 ppm | cation traces Ag: ≤5 ppm, Al: ≤10 ppm, Ba: ≤5 ppm, Ca: ≤20 ppm, Cd: ≤5 ppm, Co: ≤5 ppm, Cr: ≤5 ppm, Cu: ≤5 ppm, Fe: ≤10 ppm, Ga: ≤5 ppm, K: ≤10 ppm, Mg: ≤5 ppm, Mn: ≤5 ppm, Na: ≤20 ppm, Ni: ≤5 ppm, Pb: ≤5 ppm, Sr: ≤5 ppm, Zn: ≤5 ppm | cation traces Ag: ≤5 ppm, Al: ≤10 ppm, Ba: ≤5 ppm, Ca: ≤20 ppm, Cd: ≤5 ppm, Co: ≤5 ppm, Cr: ≤5 ppm, Cu: ≤5 ppm, Fe: ≤10 ppm, Ga: ≤5 ppm, K: ≤10 ppm, Mg: ≤5 ppm, Mn: ≤5 ppm, Na: ≤20 ppm, Ni: ≤5 ppm, Pb: ≤5 ppm, Sr: ≤5 ppm, Zn: ≤5 ppm | cation traces Ag: ≤5 ppm, Al: ≤10 ppm, Ba: ≤5 ppm, Ca: ≤20 ppm, Cd: ≤5 ppm, Co: ≤5 ppm, Cr: ≤5 ppm, Cu: ≤5 ppm, Fe: ≤10 ppm, Ga: ≤5 ppm, K: ≤10 ppm, Mg: ≤5 ppm, Mn: ≤5 ppm, Na: ≤20 ppm, Ni: ≤5 ppm, Pb: ≤5 ppm, Sr: ≤5 ppm, Zn: ≤5 ppm |
Anwendung
- X-ray Fluorescence (XRF) Analysis: Used as a flux to prepare samples for XRF analysis. It helps in creating a homogeneous glass bead from the sample, which is essential for accurate and reproducible XRF measurements.
- Sample Preparation: Employed in the fusion of samples, particularly for geological, environmental, and industrial materials to ensure that the sample is evenly distributed and free from matrix effects, which can interfere with the analysis.
Hinweis zur Analyse
Chlorid (Cl): ≤ 50 ppm
Phosphat (PO₄): ≤ 20 ppm
Silicat (SiO₂): ≤ 100 ppm
Sulfat (SO₄): ≤ 50 ppm
Ag (Silber): ≤ 5 ppm
Al (Aluminium): ≤ 10 ppm
Ba (Barium): ≤ 5 ppm
Ca (Calcium): ≤ 20 ppm
Cd (Cadmium): ≤ 5 ppm
(Cobalt): ≤ 5 ppm
Cr (Chrom): ≤ 5 ppm
Cu (Kupfer): ≤ 5 ppm
Fe (Eisen): ≤ 10 ppm
Ga (Gallium): ≤ 5 ppm
K (Kalium): ≤ 10 ppm
Mg (Magnesium): ≤ 5 ppm
Mn (Mangan): ≤ 5 ppm
Na (Natrium): ≤ 20 ppm
Ni (Nickel): ≤ 5 ppm
Pb (Blei): ≤ 5 ppm
Sr (Strontium): ≤ 5 ppm
Zn (Zink): ≤ 5 ppm
Glühverlust (1000 °C): ≤ 1,0 %
Schüttdichte: ca. 50
Sonstige Hinweise
Rechtliche Hinweise
Signalwort
Danger
H-Sätze
Gefahreneinstufungen
Acute Tox. 4 Oral - Eye Dam. 1 - Repr. 2
Lagerklassenschlüssel
13 - Non Combustible Solids
WGK
WGK 2
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Verwandter Inhalt
Atomic spectroscopy techniques like AAS, AES, ICP-OES, and ICP-MS identify and quantify elemental composition in samples.
Atomspektroskopische Verfahren wie AAS, AES, ICP-OES und ICP-MS identifizieren und quantifizieren die elementare Zusammensetzung von Proben.
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung