Direkt zum Inhalt
Merck

Major factors modulating the serum oxalic acid level in hemodialysis patients.

Frontiers in bioscience : a journal and virtual library (2004-09-09)
Yoshihide Ogawa, Noriko Machida, Masahide Jahana, Munehisa Gakiya, Yoshiaki Chinen, Masami Oda, Makoto Morozumi, Kimio Sugaya
ZUSAMMENFASSUNG

Ascorbic acid overload and vitamin B6 deficiency have been implicated in the development of hyperoxalemia in dialysis patients, but there is still disagreement about this. Hemodialysis patients who are exposed long-term hyperoxalemia may develop secondary oxalosis with an increased risk of cardiac, vascular, and bone disease, and thus may benefit from maintaining a low serum oxalic acid level. In 452 hemodialysis patients, the serum level of oxalic acid was 47.2 +/- 22.9 micromol /l before and 16.9 +/- 10.5 micromol/l after a 4-hour dialysis session, while the ascorbic acid levels were 39.0 +/- 92.7 micromol/l and 6.5 +/- 18.6 micromol/l, the glycolic acid levels were 7.3 +/- 10.1 micromol/l and 0.6 +/- 2.3 micromol/l, and the citric acid levels were 141.3 +/- 54.7 micromol/l and 117.6 +/- 37.2 micromol/l, respectively. Most patients (65.3 percent) had low serum ascorbic acid levels (less than 10 micromol/l) before hemodialysis. The serum level of oxalic acid [Ox] showed a significant positive correlation with the levels of ascorbic acid [AA], glycolic acid [Gly], and creatinine [Cre]: [Ox] = 21.711 + 0.181 x [AA] + 0.174 x [Gly] + 0.171 x [Cre], (all micromol/l, p less than 0.05). In 124 dialysis patients, the 4-pyridoxic acid level was 8.9 +/- 19.6 micromol /l before and 3.9 +/- 8.8 micromol/l after dialysis, and it was not correlated with oxalic acid or glycolic acid. Most dialysis patients (65.3 percent) had low serum levels of ascorbic acid, but a subgroup of patients (12 percent) had high serum ascorbic acid levels (more than 100 micromol/l) associated with hyperoxalemia (88.2 +/- 24.5 micromol/l). High-dose vitamin C supplementation may aggravate hyperoxalemia in hemodialysis patients, so attention should be paid to avoiding this risk.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Zitronensäure, meets analytical specification of Ph. Eur., BP, USP, E330, anhydrous, 99.5-100.5% (based on anhydrous substance)
Sigma-Aldrich
Retinol, synthetic, ≥95% (HPLC), (Powder or Powder with Lumps)
Sigma-Aldrich
Betain -Lösung, 5 M, PCR Reagent
Sigma-Aldrich
Zitronensäure, ACS reagent, ≥99.5%
Sigma-Aldrich
Oxalsäure, 98%
Sigma-Aldrich
L-Prolin, from non-animal source, meets EP, USP testing specifications, suitable for cell culture
Sigma-Aldrich
Zink, dust, <10 μm, ≥98%
Sigma-Aldrich
Betain, BioUltra, ≥99.0% (NT)
Sigma-Aldrich
Zitronensäure, ≥99.5%, FCC, FG
Sigma-Aldrich
Zitronensäure, 99%
Sigma-Aldrich
Retinol, BioXtra, ≥97.5% (HPLC), ~3100 U/mg
Sigma-Aldrich
Glycolsäure, ReagentPlus®, 99%
Sigma-Aldrich
Zink, granular, 20-30 mesh, ACS reagent, ≥99.8%
Sigma-Aldrich
Betain, ≥98% (perchloric acid titration)
Sigma-Aldrich
Oxalsäure, ReagentPlus®, ≥99%
Sigma-Aldrich
Zitronensäure, anhydrous, suitable for cell culture, suitable for plant cell culture
Sigma-Aldrich
Zink, powder, <150 μm, 99.995% trace metals basis
Sigma-Aldrich
p-Cresol, 99%
Sigma-Aldrich
L-Prolin, ReagentPlus®, ≥99% (HPLC)
SAFC
L-Prolin
Sigma-Aldrich
L-Prolin, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
Trans-4-Hydroxy-L-Prolin, ≥99%
Sigma-Aldrich
Oxalsäure, purified grade, 99.999% trace metals basis
Sigma-Aldrich
Retinol, ≥95.0% (HPLC), ~2700 U/mg
Supelco
Citronensäure, wasserfrei, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Oxalsäure, puriss. p.a., anhydrous, ≥99.0% (RT)
Sigma-Aldrich
Zitronensäure, BioUltra, anhydrous, ≥99.5% (T)
Sigma-Aldrich
Zink, foil, thickness 0.25 mm, 99.9% trace metals basis
Sigma-Aldrich
Phthalsäure, ACS reagent, ≥99.5%
Sigma-Aldrich
L-Prolin, 99%, FCC, FG