Direkt zum Inhalt
Merck
  • A new analytical method to determine non-steroidal anti-inflammatory drugs in surface water using in situ derivatization combined with ultrasound-assisted emulsification microextraction followed by gas chromatography-mass spectrometry.

A new analytical method to determine non-steroidal anti-inflammatory drugs in surface water using in situ derivatization combined with ultrasound-assisted emulsification microextraction followed by gas chromatography-mass spectrometry.

Talanta (2014-08-17)
Cheong Hoon Lee, Yujin Shin, Min Woo Nam, Kyung Min Jeong, Jeongmi Lee
ZUSAMMENFASSUNG

Because of the high stability and potential toxic effects of non-steroidal anti-inflammatory drugs (NSAIDs), it is important to closely monitor their concentrations in the environment using a sensitive analytical method. In this study, a simple, rapid, efficient, and sensitive analytical method based on gas chromatography-mass spectrometry (GC-MS) was developed to determine the levels of seven common NSAIDs in various types of surface water. To simplify sample preparation, in situ derivatization using methyl chloroformate was combined with ultrasound-assisted emulsification microextraction. For selection and optimization of significant variables, experiments were statistically designed using Plackett-Burman design and central composite design. The resulting optimal conditions for derivatization and extraction were 100 μL of chloroform (extraction solvent), 10.0 mL of sample, and 240 μL of pyridine (catalyst as a base in derivatization). The optimized sample preparation coupled with optimized GC-MS analysis in selected ion monitoring mode provided good linearity from 0.010 to 5.0 ng mL(-1), and a limit of detection between 0.0050 and 0.010 ng mL(-1), good intra-day and inter-day precision (0.30-6.3% and 5.1-9.5%, respectively), and good accuracy (relative recovery; 91-117% at 0.20 ng mL(-1) and 77-105% at 2.5 ng mL(-1)). Compared with previously reported methods, the current method requires a small volume of sample and simple sample preparation steps for sensitive determination of NSAID levels using a conventional GC-MS system. The method was successfully applied to determine the levels of seven common NSAIDs in various types of surface water.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Ethylacetat, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethylacetat, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Diethylether, anhydrous, ACS reagent, ≥99.0%, contains BHT as inhibitor
Sigma-Aldrich
Chloroform, contains 100-200 ppm amylenes as stabilizer, ≥99.5%
Sigma-Aldrich
Toluol, ACS reagent, ≥99.5%
Sigma-Aldrich
Chloroform, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains amylenes as stabilizer
Sigma-Aldrich
Pyridin, ACS reagent, ≥99.0%
Sigma-Aldrich
Ethylacetat, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Diethylether, suitable for HPLC, ≥99.9%, inhibitor-free
Sigma-Aldrich
Chloroform, contains ethanol as stabilizer, ACS reagent, ≥99.8%
Sigma-Aldrich
Chloroform, suitable for HPLC, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Toluol, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Diethylether, ACS reagent, anhydrous, ≥99.0%, contains BHT as inhibitor
Sigma-Aldrich
Toluol, anhydrous, 99.8%
Sigma-Aldrich
Cyclohexan, ACS reagent, ≥99%
Sigma-Aldrich
Cyclohexan, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Pyridin, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Pyridin, anhydrous, 99.8%
Sigma-Aldrich
Chloroform, contains amylenes as stabilizer, ACS reagent, ≥99.8%
Sigma-Aldrich
Chloroform, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Ethylacetat, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Ethylacetat, anhydrous, 99.8%
Sigma-Aldrich
Diethylether, contains 1 ppm BHT as inhibitor, anhydrous, ≥99.7%
Sigma-Aldrich
Ibuprofen, ≥98% (GC)
Sigma-Aldrich
Chloroform, ACS spectrophotometric grade, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Supelco
Ibuprofen, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Chloroform, ReagentPlus®, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Chloroform, anhydrous, ≥99%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Indomethacin, 98.0-102.0%, meets EP testing specifications
Sigma-Aldrich
Chloroform, anhydrous, contains amylenes as stabilizer, ≥99%