Passa al contenuto
Merck

57310-U

Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB)

greener alternative

65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub

Sinonimo/i:

SPME FIBER PK3(MANUAL),W/65UM PS-DVB COATING

Autenticati per visualizzare i prezzi organizzativi e contrattuali.

Scegli un formato

Prezzi e disponibilità al momento non sono disponibili

Informazioni su questo articolo

UNSPSC Code:
41115724
NACRES:
NB.21

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Nome del prodotto

Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub

material

blue hub
fused silica fiber

needle size

24 ga

packaging

pk of 3

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

df

65 μm (PDMS/DVB)

technique(s)

solid phase microextraction (SPME): suitable

fiber L

1 cm

matrix active group

PDMS/DVB coating

application(s)

food and beverages

compatibility

Manual Holder
for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300)

greener alternative category

Quality Level

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
57346-U57345-U57327-U
material

fused silica fiber, plain blue hub

material

fused silica fiber, plain blue hub

material

fused silica fiber, plain blue hub

material

StableFlex fiber, plain pink hub

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with manual holder

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with manual holder

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with autosampler

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with autosampler

matrix active group

PDMS/DVB coating

matrix active group

PDMS/DVB coating

matrix active group

PDMS/DVB coating

matrix active group

PDMS/DVB coating

df

65 μm (PDMS/DVB)

df

65 μm (PDMS/DVB)

df

65 μm (PDMS/DVB)

df

65 μm (PDMS/DVB)

needle size

24 ga

needle size

23 ga

needle size

23 ga

needle size

24 ga

packaging

pkg of 3 ea

packaging

pkg of 3 ea

packaging

pkg of 3 ea

packaging

pkg of 3 ea

Application

Volatiles, Amines, and Nitroaromatic Compounds

General description

We are committed to bringing you greener alternative products, which adhere to one or more of The 12 Principles of Greener Chemistry. This is a Solid Phase Microextraction (SPME) technology product. SPME is one of the greener technologies for sample preparation as it is solvent free extraction technology and SPME fibres are re-usable and generates as little waste as possible, thus aligns with "Waste Prevention”, and ″Safer Solvents and Auxiliaries″. Click here for more information.

Other Notes

This SPME fiber assembly is also available with a Nitinol (NIT) core as Cat. No. 57921-U, providing enhanced fiber reproducibility, greater fiber durability, maintained selectivity for method consistency, and core inertness to ensure analyte stability. See more at SigmaAldrich.com/NITSPME .

Classe di stoccaggio

11 - Combustible Solids

wgk

WGK 2


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

C A Groom et al.
Journal of chromatography. A, 909(1), 53-60 (2001-02-24)
The cyclic nitramine explosives hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX) were examined in field and microcosm soil samples to determine their patterns of degradation and environmental fates. A number of analytical techniques, including solid-phase microextraction with on-fiber derivatization, gas chromatography-mass spectrometry
Marisela Pontes et al.
Food chemistry, 134(4), 2509-2520 (2013-02-28)
In this study the effect of the cultivar on the volatile profile of five different banana varieties was evaluated and determined by dynamic headspace solid-phase microextraction (dHS-SPME) combined with one-dimensional gas chromatography-mass spectrometry (1D-GC-qMS). This approach allowed the definition of
Jing Cheng et al.
Journal of chromatography. A, 1218(18), 2476-2482 (2011-03-23)
A novel ultrasound-assisted surfactant-enhanced emulsification microextraction (UASEME) technique has been proposed by using low-density extraction solvents. In the proposed technique, Tween 80 and cyclohexane were injected into 5-mL glass test tubes with conical bottoms, containing 5.00 mL of a water
Brunella Cavaliere et al.
Journal of chromatography. A, 1257, 149-157 (2012-08-22)
A simple and sensitive method was developed for the quantification of five carbamate pesticides in water samples using solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS). The performance of five SPME fibers was tested in univariate
Noureddine Yassaa et al.
Journal of chromatography. A, 1141(1), 138-144 (2006-12-19)
In order to develop a valuable method for accurate screening of biogenic emissions from undisturbed living plants or for plant-insect interactions, solid-phase microextraction (SPME) has been combined with dynamic branch enclosure cuvettes and enantioselective GC/MS. The study was conducted at

Contenuto correlato

La microextraction en phase solide (SPME) est une technique de préparation d'échantillons sans solvant, qui se sert de fibres enrobées pour extraire les analytes d'intérêt de l'échantillon avant analyse par GC ou HPLC.

Solid phase microextraction (SPME) is a solvent-free sample preparation technique that uses coated fibers to extract analytes of interest from a sample before analysis by GC or HPLC.

La microestrazione in fase solida (SPME) è una tecnica di preparazione del campione che non prevede l’impiego di solventi, ma che utilizza fibre rivestite per estrarre gli analiti d’interesse da un campione prima dell’analisi mediante GC o HPLC.

Die Festphasenmikroextraktion (SPME) ist eine lösungsmittelfreie Probenvorbereitungstechnik, bei der beschichtete Fasern verwendet werden, um Zielanalyten aus einer Probe zu extrahieren, bevor sie mittels GC oder HPLC analysiert werden.

Vedi tutto

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica