Passa al contenuto
Merck
  • Capillary electromigration techniques as tools for assessing the status of vitamins A, C and E in patients with cystic fibrosis.

Capillary electromigration techniques as tools for assessing the status of vitamins A, C and E in patients with cystic fibrosis.

Journal of pharmaceutical and biomedical analysis (2014-09-23)
Ilona Olędzka, Katarzyna Kaźmierska, Alina Plenis, Barbara Kamińska, Tomasz Bączek
ABSTRACT

The purpose of this work is the evaluation of the nutritional status of patients with cystic fibrosis (CF), based on the level of vitamin C in urine and vitamins A and E in serum, using the fast, selective and fully automated micellar electrokinetic capillary chromatographic (MEKC) and microemulsion electrokinetic capillary chromatographic (MEEKC) methods. The optimization of parameters affecting the electrophoretic separation provided adequate separation of the analytes of interest in the short time of 8 min (MEKC) and 20 min (MEEKC). The developed methods were practical applications to evaluate the levels of vitamins A, C and E in real samples from 28 children suffering from cystic fibrosis and from 10 healthy volunteers. Based on the mean concentration values obtained in the two groups, it can be seen that the levels of each vitamin were lower in patients with CF than in healthy volunteers. In the case of vitamin E, these differences in both groups were statistically significant, while the disproportion of concentrations of vitamins A and C in both the studied groups were not so relevant. On the other hand, a principal component analysis (PCA) confirmed that in some patients with CF the concentration of vitamin A was significantly lower than in the control group. Thus, the future evaluation of the status of fat-soluble vitamins in the longer term for the evaluation of the nutritional status of patients with CF should be continued. The presented CE methods can become useful tools for the evaluation of the nutritional status of patients with CF.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
2-Propanolo, suitable for HPLC, 99.9%
Sigma-Aldrich
Acetone, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanolo, ACS reagent, ≥99.5%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Diclorometano, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Diclorometano, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetone, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Diclorometano, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Sodio dodecil solfato, BioReagent, suitable for electrophoresis, Molecular Biology, ≥98.5% (GC)
Sigma-Aldrich
Acetone, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
Esano, suitable for HPLC, ≥97.0% (GC)
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acido borico, ACS reagent, ≥99.5%
Sigma-Aldrich
Esano, ReagentPlus®, ≥99%
Sigma-Aldrich
Diclorometano, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
2-Propanolo, BioReagent, ≥99.5%, Molecular Biology
Sigma-Aldrich
Esano, suitable for HPLC, ≥95%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
1-butanolo, 99.9%
Sigma-Aldrich
2-Propanolo, meets USP testing specifications
Sigma-Aldrich
2-Propanolo, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Metanolo, anhydrous, 99.8%
Sigma-Aldrich
Sodio dodecil solfato, ≥99.0% (GC), dust-free pellets
Sigma-Aldrich
1-butanolo, ACS reagent, ≥99.4%