Passa al contenuto
Merck
  • A method for quantification of volatile organic compounds in blood by SPME-GC-MS/MS with broader application: From non-occupational exposure population to exposure studies.

A method for quantification of volatile organic compounds in blood by SPME-GC-MS/MS with broader application: From non-occupational exposure population to exposure studies.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-05-13)
Rocio Aranda-Rodriguez, Ashley Cabecinha, Jeromy Harvie, Zhiyun Jin, Axelle Marchand, Robert Tardif, Andy Nong, Sami Haddad
ABSTRACT

Humans are continuously exposed to volatile organic compounds (VOCs) as these chemicals are ubiquitously present in most indoor and outdoor environments. In order to assess recent exposure to VOCs for population-based studies, VOCs are measured in the blood of participants. This work describes an improved method to detect 12 VOCs by head-space solid-phase microextraction gas chromatography coupled with isotope-dilution mass spectrometry in selected reaction monitoring mode (SPME-GC-MS/MS). This method was applied to the analysis of trihalomethanes, styrene, trichloroethylene, tetrachloroethylene and BTEX (benzene, toluene, ethylbenzene, m-xylene, p-xylene, o-xylene) in a population-based biomonitoring study (Canadian Health Measures Survey). The method showed good linearity (>0.990) in the range of 0.010-10μg/L and detection limits between 0.007 and 0.027μg/L, precision better than 25% and good accuracy (±25%) based on proficiency testing materials. Quality Control data among runs over a 7 month period showed %RSD between 14 and 25% at low levels (∼0.03μg/L) and between 9 and 23% at high levels (∼0.4μg/L). The method was modified to analyze samples from a pharmacokinetic study in which 5 healthy volunteers were exposed to single, binary and quaternary mixtures of CTEX (chloroform, ethylbenzene, toluene and m-xylene), thus the expected concentration in blood was 1 order of magnitude higher than those found in the general population. The method was modified by reducing the sample size (from 3g to 0.5g) and increasing the upper limit of the concentration range to 395μg/L. Good linearity was found in the range of 0.13-395μg/L for toluene and ethylbenzene and 0.20-609μg/L for m/p-xylene. Quality control data among runs over the period of the study (n=13) were found to vary between 7 and 25%.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, anhydrous, 99.8%
Sigma-Aldrich
Styrene, ReagentPlus®, contains 4-tert-butylcatechol as stabilizer, ≥99%
Sigma-Aldrich
Benzene, anhydrous, 99.8%
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, red hub
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, red hub
Sigma-Aldrich
Sodium fluoride, 99.99% trace metals basis
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, red hub
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, pink hub
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, blue hub
Sigma-Aldrich
Tetrachloroethylene, anhydrous, ≥99%
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, pink hub
Sigma-Aldrich
Sodium fluoride, BioXtra, ≥99%
Sigma-Aldrich
Sodium Fluoride Solution
Sigma-Aldrich
Sodium fluoride, BioReagent, suitable for insect cell culture, ≥99%
Supelco
Gruppo fibre SPME poliacrilato (PA), 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, white hub
Sigma-Aldrich
Rhein, technical grade
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, pink hub
Supelco
SPME Portable Field Sampler, coating PDMS/DVB
Sigma-Aldrich
Trichloroethylene, anhydrous, contains 40 ppm diisopropylamine as stabilizer, ≥99%
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, blue hub
Supelco
Gruppo fibre SPME poliacrilato (PA), 85 μm Polyacrylate, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, white hub
Supelco
SPME Portable Field Sampler, coating PDMS
Supelco
SPME Fiber Assembly Kit, Assortment, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 4
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, red hub
Sigma-Aldrich
Rhein
Supelco
SPME Fiber Assembly Kit, Assortment, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 4
Supelco
SPME Portable Field Sampler, coating CAR/PDMS
Supelco
SPME Fiber Assembly Kit, Assortment #4, Fused Silica (1 cm), size 24 ga, Manual Holder, pk of 3
Supelco
Gruppo fibre SPME, rivestimento in glicole polietilenico (PEG) Carbowax, 60 μm PEG, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 3, purple hub