Scegli un formato
| Voi/SKU | Disponibilità | Prezzo |
|---|---|---|
1 ea | Spedizione prevista il04 dicembre 2026daMerck Life Science S.r.l. | 651,00 € |
Informazioni su questo articolo
651,00 €
Spedizione prevista il04 dicembre 2026Dettagli
Quality Segment
material
TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen
feature
holdup volume 3.6 mL (in feed channel)
manufacturer/tradename
Pellicon®
parameter
2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C
technique(s)
analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)
H
0.8 cm (0.33 in.)
L
20.6 cm (8.1 in.)
W
5.6 cm (2.2 in.)
filtration area
88 cm2
membrane area
88 cm2
gravimetric extractables
≤1500 mg/m2
matrix
Ultracel® (Membrane)
pore size
30 kDa NMWCO
pH
2-13
shipped in
ambient
General description
Le cassette Pellicon® 3 con membrana Ultracel® sono progettate per la filtrazione di proteine terapeutiche (come gli anticorpi monoclonali) e le proteine ricombinanti e non ricombinanti
Questo dispositivo per ultrafiltrazione Pellicon® 3 (P3C030D00) è caratterizzato da pori da 30 kDa NMWCO, una superficie di filtrazione di 88 cm2 e una membrana PLCTK e misura 3,8 cm (alt.) x 17,8 cm (larg.) x 20,6 cm (lung.).
Features and Benefits
- Robusta & affidabile – si adatta perfettamente ai processi di filtrazione di oggi, particolarmente complessi
- Prestazioni elevate – garantisce risoluzione, rese e resistenza alla contropressione ottimali.
- Recupero eccellente del prodotto – utilizzando membrane a tecnologia consolidata
- Tecnologia void-free (niente spazi vuoti) – le membrane di nuova generazione sono in grado di risolvere praticamente qualsiasi problema di separazione
- Priva di imperfezioni, per un′aderenza eccellente – Ultracel® utilizza membrane composite accoppiate ad un substrato microporoso
- Produzione automatizzata – assicura un livello e una continuità di prestazioni nonché un′affidabilità ineguagliabili
- Installazione & manutenzione senza problemi – facile da istallare, facile da manutenere
Analysis Note
Other Notes
Legal Information
1 of 1
Questo articolo | |||
|---|---|---|---|
| description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 3.6 mL (in feed channel) | description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 1.5 mL (in feed channel) | description filtration area 88 cm2, NMWCO 5 kDa | description filtration area 0.11 m2, NMWCO 30 kDa |
| pore size 30 kDa NMWCO | pore size 30 kDa NMWCO | pore size 5 kDa NMWCO | pore size 30 kDa NMWCO |
| technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) protein purification: suitable (concentration), buffer exchange: suitable, analytical sample preparation: suitable | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration) |
| filtration area 88 cm2 | filtration area 88 cm2 | filtration area 88 cm2 | filtration area 0.11 m2 |
| matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) |
| material composite regenerated cellulose (CRC) membrane, polypropylene cap (for end), TPE seal, polypropylene screen | material polypropylene cap (for end), composite regenerated cellulose (CRC) membrane, TPE seal, polypropylene screen | material TPE seal, polypropylene cap (for end), composite regenerated cellulose (CRC) membrane, polypropylene screen | material composite regenerated cellulose (CRC) , TPE seal, polypropylene cap (for end), polypropylene screen |
| parameter 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 2.75 bar max. inlet pressure (40 psi) at 50 °C, 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C | parameter 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 6.9 bar max. inlet pressure (100 psi), 2.75 bar max. inlet pressure (40 psi) at 50 °C | parameter 6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 2.75 bar max. inlet pressure (40 psi) at 50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 40 psi max. transmembrane pressure at 4-50 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate, 6.9 bar max. inlet pressure (100 psi) |
Still not finding the right product?
Explore all of our products under Cassetta Pellicon® 3 con membrana Ultracel® 30 kDa, D Screen, 88 cm2
Classe di stoccaggio
10 - Combustible liquids
wgk
WGK 2
Elenchi normativi
Forniamo informazioni su eventuali restrizioni prevalentemente per i prodotti chimici. Per altre tipologie di prodotto siamo in grado di fornire soltanto informazioni limitate. Nessuna segnalazione significa che nessuno dei componenti è citato in un elenco. È dovere dell’utilizzatore assicurarsi che il prodotto venga impiegato in maniera sicura e a norme di legge.
64-19-7
Mantenere la conformità alle GMP utilizzando il programma Emprove®.
Accelerate la qualificazione, mantenete la conformità e risparmiate tempo con Emprove® Dossiers.
Nota: verrete portati su EmproveSuite.com. Il vostro nome utente e la vostra password sono separati da SigmaAldrich.com e possono essere diversi.
Registrati gratuitamente e accedi a Emprove® Dossiers in pochi minuti. Aggiornate il vostro piano di abbonamento per sbloccare contenuti avanzati e personalizzati nella Emprove® Suite.
Non trovate quello che state cercando? Visitate la pagina di aiuto del programma Emprove®..
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Non riesci a trovare il codice del tuo prodotto o il numero di lotto/ batch?
Come trovare il codice prodotto
I numeri di catalogo dei prodotti nel sito internet sono associati al taglio o alla quantità delle confezioni (es: T1503-25G). Accertati Nel campo N° Catalogo digita SOLO il N° di catalogo del prodotto (Esempio: T1503).
Esempio:
Altri esempi:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
Inseriscilo come 1.000309185)