Passa al contenuto
Merck
  • Modified screen-printed ion selective electrodes for potentiometric determination of sodium dodecylsulfate in different samples.

Modified screen-printed ion selective electrodes for potentiometric determination of sodium dodecylsulfate in different samples.

Journal of AOAC International (2015-04-11)
Tamer Awad Ali, Gehad G Mohamed
ABSTRACT

Fabrication and general performance characteristics of novel screen-printed sensors for potentiometric determination of sodium dodecylsulfate (SDS) are described. The sensors are based on the use of ion-association complexes of SDS with cetylpyridinium chloride (electrode I) and cetyltrimethylammonium bromide (electrode II) as exchange sites in a screen-printed electrode matrix. Electrodes (I) and (II) show fast, stable, and near-Nernstian response for the mono-charge anion of SDS over the concentration range of 1×10(-2) - 5.8×10(-7) and 1×10(-2)-6.3×10(-7) mol/L at 25°C and the pH range of 2.0-9.0 and 2.0-8.0 with anionic slope of 57.32±0.81 and 56.58±0.65 mV/decade, respectively. Electrodes (I) and (II) have lower LODs of 5.8×10(-7) and 6.3×10(-7) mol/L and response times of about 8 and 13 s, respectively. Shelf life of 5 months for both electrodes is adequate. Selectivity coefficients of SDS related to a number of interfering cations, and some inorganic compounds were investigated. There were negligible interferences caused by most of the investigated species. The direct determination of 0.10-13.50 mg of SDS by electrodes (I) and (II) shows average recoveries of 99.96 and 99.85%, and mean RSDs of 0.83 and 1.04%, respectively. In the present investigation, both electrodes were used successfully as end point indicators for determination of SDS in pure pharmaceutical preparations and real spiked water samples. The results obtained using the proposed sensors to determine SDS in solution compared favorably with those obtained by the standard addition method.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Sigma-Aldrich
Sodio dodecil solfato, BioReagent, suitable for electrophoresis, Molecular Biology, ≥98.5% (GC)
Sigma-Aldrich
Esadeciltrimetilammonio bromuro, ≥98%
Sigma-Aldrich
Sodio dodecil solfato, ≥99.0% (GC), dust-free pellets
Sigma-Aldrich
Sodio dodecil solfato, ACS reagent, ≥99.0%
Sigma-Aldrich
Sodio dodecil solfato, BioUltra, Molecular Biology, 10% in H2O
Sigma-Aldrich
Esadeciltrimetilammonio bromuro, Molecular Biology, ≥99%
Sigma-Aldrich
Sodio dodecil solfato, ReagentPlus®, ≥98.5% (GC)
Sigma-Aldrich
Fosfato di sodio, meets analytical specification of Ph. Eur., BP, E339, 98.5-102.5% (T)
Sigma-Aldrich
Dibutilftalato, 99%
Sigma-Aldrich
Sodio dodecil solfato, BioUltra, Molecular Biology, ≥99.0% (GC)
Sigma-Aldrich
Sodio dodecil solfato, BioUltra, 20% in H2O
Sigma-Aldrich
Dioctyl phthalate, ≥99.5%
Supelco
Sodio dodecil solfato, dust-free pellets, suitable for electrophoresis, Molecular Biology, ≥99.0% (GC)
Sigma-Aldrich
Esadeciltrimetilammonio bromuro, BioXtra, ≥99%
Supelco
Sodio dodecil solfato, suitable for ion pair chromatography, LiChropur, ≥99.0%
Sigma-Aldrich
Fosfato di sodio, BioXtra, ≥99.0% (T)
Sigma-Aldrich
Sodio dodecil solfato, BioXtra, ≥99.0% (GC)
Sigma-Aldrich
Sodio dodecil solfato, ≥98.0% (GC)
Sigma-Aldrich
Esadeciltrimetilammonio bromuro, BioUltra, Molecular Biology, ≥99.0% (AT)
Sigma-Aldrich
Sodio dodecil solfato, 92.5-100.5% based on total alkyl sulfate content basis
Sigma-Aldrich
Fosfato di sodio, tested according to Ph. Eur.
Supelco
Bis(2-ethylhexyl) phthalate, PESTANAL®, analytical standard
Sigma-Aldrich
Esadeciltrimetilammonio bromuro, ≥96.0% (AT)
Sigma-Aldrich
Sodio dodecil solfato, ≥90% ((Assay))
Sigma-Aldrich
Di-n-octyl phthalate, ≥98.0% (GC)
Sigma-Aldrich
Sodio dodecil solfato, mixture of sodium alkyl sulfates consisting mainly of sodium dodecyl sulfate
Sigma-Aldrich
Dioctyl sebacate, AldrichCPR
Supelco
Dibutilftalato, PESTANAL®, analytical standard
Supelco
Bis(2-ethylhexyl) phthalate, Selectophore
USP
Esadeciltrimetilammonio bromuro, United States Pharmacopeia (USP) Reference Standard